Accuracy and clinical performance of a continuous intra-arterial blood-gas monitoring system during thoracoscopic surgery

Author keywords

Equipment, blood gas monitors; Measurement techniques, gas exchange; Surgery, thoracic; Ventilation, one lung

Indexed keywords

ACCURACY; ADULT; AGED; ARTERIAL CARBON DIOXIDE TENSION; ARTERIAL GAS; ARTERIAL OXYGEN TENSION; ARTICLE; BLOOD GAS ANALYSIS; BLOOD PH; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; HUMAN; LUNG VENTILATION; MALE; PATIENT MONITORING; PRIORITY JOURNAL; THORACOSCOPY;

EID: 0030787315     PISSN: 00070912     EISSN: None     Source Type: Journal    
DOI: 10.1093/bja/79.1.47     Document Type: Article
Times cited : (39)

References (34)
  • 3
    • 0028214567 scopus 로고
    • A multiparameter sensor for continuous intra-arterial blood gas monitoring: A prospective evaluation
    • Venkatesh B, Clutton-Brock TH, Hendry SP. A multiparameter sensor for continuous intra-arterial blood gas monitoring: a prospective evaluation. Critical Care Medicine 1994; 22: 588-594.
    • (1994) Critical Care Medicine , vol.22 , pp. 588-594
    • Venkatesh, B.1    Clutton-Brock, T.H.2    Hendry, S.P.3
  • 4
    • 0029151933 scopus 로고
    • Evaluation of the Paratrend 7 intravascular blood gas monitor during cardiac surgery: Comparison with the C4000 in-line blood gas monitor during cardiopulmonary bypass
    • Venkatesh B, Clutton-Brock TH, Hendry SP. Evaluation of the Paratrend 7 intravascular blood gas monitor during cardiac surgery: comparison with the C4000 in-line blood gas monitor during cardiopulmonary bypass. Journal of Cardiothoracic and Vascular Anesthesia 1995; 9: 412-419.
    • (1995) Journal of Cardiothoracic and Vascular Anesthesia , vol.9 , pp. 412-419
    • Venkatesh, B.1    Clutton-Brock, T.H.2    Hendry, S.P.3
  • 6
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 7
    • 0028248942 scopus 로고
    • Continuous intra-arterial blood gas monitoring
    • Mahutte CK. Continuous intra-arterial blood gas monitoring. Intensive Care Medicine 1994; 20: 85-86.
    • (1994) Intensive Care Medicine , vol.20 , pp. 85-86
    • Mahutte, C.K.1
  • 8
    • 0026522192 scopus 로고
    • In vivo monitoring of arterial blood gases and pH
    • Shapiro BA. In vivo monitoring of arterial blood gases and pH. Respiratory Care 1992; 37: 165-169.
    • (1992) Respiratory Care , vol.37 , pp. 165-169
    • Shapiro, B.A.1
  • 9
    • 0027973811 scopus 로고
    • Multisite evaluation of a continuous intraarterial blood gas monitoring system
    • Larson CP, Vender J, Seiver A. Multisite evaluation of a continuous intraarterial blood gas monitoring system. Anesthesiology 1994; 81: 543-552.
    • (1994) Anesthesiology , vol.81 , pp. 543-552
    • Larson, C.P.1    Vender, J.2    Seiver, A.3
  • 10
    • 0029850372 scopus 로고    scopus 로고
    • Clinical evaluation of a continuous intra-arterial blood gas system in critically ill patients
    • Roupie EE, Brochard L, Lemaire FJ. Clinical evaluation of a continuous intra-arterial blood gas system in critically ill patients. Intensive Care Medicine 1996; 22: 1162-1168.
    • (1996) Intensive Care Medicine , vol.22 , pp. 1162-1168
    • Roupie, E.E.1    Brochard, L.2    Lemaire, F.J.3
  • 12
    • 0026612792 scopus 로고
    • Clinical evaluation - Continuous real-time intra-arterial blood gas monitoring during anesthesia and surgery by fiber optic sensor
    • Smith BE, King PH, Schlain L. Clinical evaluation - continuous real-time intra-arterial blood gas monitoring during anesthesia and surgery by fiber optic sensor. International Journal of Clinical Monitoring and Computing 1992; 9: 45-52.
    • (1992) International Journal of Clinical Monitoring and Computing , vol.9 , pp. 45-52
    • Smith, B.E.1    King, P.H.2    Schlain, L.3
  • 13
    • 0027413775 scopus 로고
    • Initial evaluation of a new intra-arterial blood gas system in humans
    • Zimmerman J, Dellinger R. Initial evaluation of a new intra-arterial blood gas system in humans. Critical Care Medicine 1993; 21: 495-500.
    • (1993) Critical Care Medicine , vol.21 , pp. 495-500
    • Zimmerman, J.1    Dellinger, R.2
  • 15
    • 0028265076 scopus 로고
    • Continuous intra-arterial blood gas and pH monitoring in critically ill patients with severe respiratory failure: A prospective criterion standard study
    • Haller M, Kilger E, Briegel J, Forst H, Peter K. Continuous intra-arterial blood gas and pH monitoring in critically ill patients with severe respiratory failure: a prospective criterion standard study. Critical Care Medicine 1994; 22: 580-587.
    • (1994) Critical Care Medicine , vol.22 , pp. 580-587
    • Haller, M.1    Kilger, E.2    Briegel, J.3    Forst, H.4    Peter, K.5
  • 17
    • 0007878577 scopus 로고
    • Blood gas monitors in the critical care setting
    • Shapiro BA. Blood gas monitors in the critical care setting. Current Opinion in Critical Care 1995; 1: 191-196.
    • (1995) Current Opinion in Critical Care , vol.1 , pp. 191-196
    • Shapiro, B.A.1
  • 18
    • 0029905663 scopus 로고    scopus 로고
    • Continuous intra-arterial blood gas monitoring
    • Venkatesh B, Hendry SP. Continuous intra-arterial blood gas monitoring. Intensive Care Medicine 1996; 22: 818-828.
    • (1996) Intensive Care Medicine , vol.22 , pp. 818-828
    • Venkatesh, B.1    Hendry, S.P.2
  • 19
    • 0020664864 scopus 로고
    • Precision and accuracy of intraoperative temperature monitoring
    • Cork RC, Vaughan RW, Humphrey LS. Precision and accuracy of intraoperative temperature monitoring. Anesthesia and Analgesia 1983; 62: 211-214.
    • (1983) Anesthesia and Analgesia , vol.62 , pp. 211-214
    • Cork, R.C.1    Vaughan, R.W.2    Humphrey, L.S.3
  • 20
  • 21
  • 22
  • 24
    • 0015241327 scopus 로고
    • Leakage of oxygen from blood and water samples stored in plastic and glass syringes
    • Scott PV, Horton JN, Mapleson WW. Leakage of oxygen from blood and water samples stored in plastic and glass syringes. British Medical Journal 1971; 3: 512-516.
    • (1971) British Medical Journal , vol.3 , pp. 512-516
    • Scott, P.V.1    Horton, J.N.2    Mapleson, W.W.3
  • 25
    • 0015262481 scopus 로고
    • A comparative study of plastic (polypropylene) and glass syringes in blood-gas analysis
    • Evers W, Racz GB, Levy AA. A comparative study of plastic (polypropylene) and glass syringes in blood-gas analysis. Anesthesia and Analgesia 1972; 51: 92-97.
    • (1972) Anesthesia and Analgesia , vol.51 , pp. 92-97
    • Evers, W.1    Racz, G.B.2    Levy, A.A.3
  • 26
    • 0023720868 scopus 로고
    • Importance of correct handling of samples for the results of blood gas analysis
    • Harsten A, Berg B, Inerot S, Muth L. Importance of correct handling of samples for the results of blood gas analysis. Acta Anaesthesiologica Scandinavica 1988; 32: 365-368.
    • (1988) Acta Anaesthesiologica Scandinavica , vol.32 , pp. 365-368
    • Harsten, A.1    Berg, B.2    Inerot, S.3    Muth, L.4
  • 27
  • 28
    • 0029078722 scopus 로고
    • Sending blood gas specimens through pressurized transport rube systems exaggerates the error in oxygen tension measurements created by the presence of air bubbles
    • McKane MH, Southorn PA, Santrach PJ, Burritt MF, Plevak DJ. Sending blood gas specimens through pressurized transport rube systems exaggerates the error in oxygen tension measurements created by the presence of air bubbles. Anesthesia and Analgesia 1995; 81: 179-182.
    • (1995) Anesthesia and Analgesia , vol.81 , pp. 179-182
    • McKane, M.H.1    Southorn, P.A.2    Santrach, P.J.3    Burritt, M.F.4    Plevak, D.J.5
  • 29
    • 0029299202 scopus 로고
    • Evaluation: Blood gas/pH analyzers
    • ECRI (Emergency Care Research Institute). Evaluation: blood gas/pH analyzers. Health Devices 1995; 24: 208-243.
    • (1995) Health Devices , vol.24 , pp. 208-243
  • 30
    • 0027406959 scopus 로고
    • Basic concepts and fundamental issues in technology assessment
    • Franklin C. Basic concepts and fundamental issues in technology assessment. Intensive Care Medicine 1993; 19: 117-121.
    • (1993) Intensive Care Medicine , vol.19 , pp. 117-121
    • Franklin, C.1
  • 31
    • 0028908538 scopus 로고
    • Technology assessment of anaesthesia monitors: Problems and future directions
    • Byrick RJ, Cohen MM. Technology assessment of anaesthesia monitors: problems and future directions. Canadian Journal of Anaesthesia 1995; 42: 234-239.
    • (1995) Canadian Journal of Anaesthesia , vol.42 , pp. 234-239
    • Byrick, R.J.1    Cohen, M.M.2
  • 32
    • 0029809692 scopus 로고    scopus 로고
    • Is continuous intra-arterial blood gas and pH monitoring justifiable?
    • Blitt CD. Is continuous intra-arterial blood gas and pH monitoring justifiable? Journal of Clinical Monitoring 1996; 12: 177.
    • (1996) Journal of Clinical Monitoring , vol.12 , pp. 177
    • Blitt, C.D.1
  • 33
    • 0030088510 scopus 로고    scopus 로고
    • Pro: Is continuous intra-arterial blood gas and pH monitoring justifiable?
    • Gilbert HC, Vender JS. Pro: Is continuous intra-arterial blood gas and pH monitoring justifiable? Journal of Clinical Monitoring 1996; 12: 179-181.
    • (1996) Journal of Clinical Monitoring , vol.12 , pp. 179-181
    • Gilbert, H.C.1    Vender, J.S.2
  • 34
    • 0030088509 scopus 로고    scopus 로고
    • Con: Is continuous intra-arterial blood gas and pH monitoring justifiable?
    • Hoffer JL, Norfleet EA. Con: Is continuous intra-arterial blood gas and pH monitoring justifiable? Journal of Clinical Monitoring 1996; 12: 183-189.
    • (1996) Journal of Clinical Monitoring , vol.12 , pp. 183-189
    • Hoffer, J.L.1    Norfleet, E.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.