Volumn , Issue , 2006, Pages 1795-1800

Automated oxidase-coupled amperometric microsensor with integrated electrochemical actuation system for continuous sensing of saccharoids

Author keywords

Actuator; Automation; Calibration; Continuous calibration sensing; GOD (glucose oxidase); LabView; LOD (lactate oxidase); Needle based amperometric sensor; Solid state biosensor; Water electrolysis

Indexed keywords

CONTINUOUS CALIBRATION; INTEGRATED ELECTROCHEMICAL ACTUATION; LACTATE OXIDASE; NEEDLE BASED AMPEROMETRIC SENSOR; SOLID-STATE BIOSENSORS; WATER ELECTROLYSIS;

EID: 36048944732     PISSN: 10915281     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IMTC.2006.235370     Document Type: Conference Paper
Times cited : (1)

References (11)
  • 1
    • 84908830001 scopus 로고
    • Can continuous glucose monitoring be used for the treatment of diabetes?
    • G. Reach and G.S. Wilson, "Can continuous glucose monitoring be used for the treatment of diabetes?", Anal. Chem., Vol. 64, No. 6, pp. 381A-386A, 1992
    • (1992) Anal. Chem , vol.64 , Issue.6
    • Reach, G.1    Wilson, G.S.2
  • 2
    • 33847180928 scopus 로고    scopus 로고
    • Glucose Oxidase (GOD)-Coupled Amperometric Microsensor with Integrated Electrochemical Actuation System
    • May
    • Jongwon Park, Chang-Soo Kim, Shanrui Zhang and Minsu Choi, "Glucose Oxidase (GOD)-Coupled Amperometric Microsensor with Integrated Electrochemical Actuation System", Instrumentation and Measurement Technology Conference (IMTC), 2005., Vol. 1, pp. 134-138, May 2005.
    • (2005) Instrumentation and Measurement Technology Conference (IMTC) , vol.1 , pp. 134-138
    • Park, J.1    Kim, C.2    Zhang, S.3    Choi, M.4
  • 3
    • 0033736885 scopus 로고    scopus 로고
    • The electrolysis of water: An actuation principle for MEMS with a big opportunity
    • PP, May
    • C. Neagu, H. Jansen, H. Gardeniers, M. Elwenspoek, "The electrolysis of water: an actuation principle for MEMS with a big opportunity,", Mechatronics, Vol. 10, PP. 571-581, May. 2000
    • (2000) Mechatronics , vol.10 , pp. 571-581
    • Neagu, C.1    Jansen, H.2    Gardeniers, H.3    Elwenspoek, M.4
  • 5
    • 2542510078 scopus 로고    scopus 로고
    • A closed-loop controlled electrochemically actuated micro-dosing system
    • PP
    • S. Bohm, B. Trimmer, P. Bergveld, "A closed-loop controlled electrochemically actuated micro-dosing system", J. Micromech. Microeng., Vol. 10 (4), PP. 498-504, 2000
    • (2000) J. Micromech. Microeng , vol.10 , Issue.4 , pp. 498-504
    • Bohm, S.1    Trimmer, B.2    Bergveld, P.3
  • 6
    • 4544356245 scopus 로고    scopus 로고
    • Chang-Soo Kim, Chae-Hyang Lee, Jason O. Fiering, Stefan Ufer, Charles W. Scarantino, H. Troy Nagle, Manipulation of microenvironment with, a built-in electrochemical actuator in proximity of a dissolved oxygen microsensor, IEEE Sensors Journal, 4, No. 5, pp. 568-575, 2004
    • Chang-Soo Kim, Chae-Hyang Lee, Jason O. Fiering, Stefan Ufer, Charles W. Scarantino, H. Troy Nagle, "Manipulation of microenvironment with, a built-in electrochemical actuator in proximity of a dissolved oxygen microsensor", IEEE Sensors Journal, Vol. 4, No. 5, pp. 568-575, 2004
  • 7
    • 19744380116 scopus 로고    scopus 로고
    • A simple on-chip self-diagnosis/ selfcalibration method of oxygen microsensor using electrochemically generated bubbles
    • J. Park, C. Kim, and Y. Kim, A simple on-chip self-diagnosis/ selfcalibration method of oxygen microsensor using electrochemically generated bubbles, Sensors and Actuators B, Vol. 108, No. 1-2, pp. 633-638, 2005
    • (2005) Sensors and Actuators B , vol.108 , Issue.1-2 , pp. 633-638
    • Park, J.1    Kim, C.2    Kim, Y.3
  • 8
    • 0030791221 scopus 로고    scopus 로고
    • Amperometric monitoring of lactate accumulation in rabbit ischemic myocardium
    • PP
    • S. Marzouk, V. Cosofret, R. Buck, H. Yang, W Cascio and S. Hassan, "Amperometric monitoring of lactate accumulation in rabbit ischemic myocardium", Talanta, Vol. 44, PP. 1527-1541, 1997
    • (1997) Talanta , vol.44 , pp. 1527-1541
    • Marzouk, S.1    Cosofret, V.2    Buck, R.3    Yang, H.4    Cascio, W.5    Hassan, S.6
  • 9
    • 0026216348 scopus 로고
    • Design and in Vitro Studies of a Needle-Type Glucose Sensor for Subcutaneous Monitoring
    • Sep
    • Bindra DS, Zhang Y, Wilson GS, Sternberg R, Thevenot DR, Moatti D and Reach G "Design and in Vitro Studies of a Needle-Type Glucose Sensor for Subcutaneous Monitoring,", Anal Chem, Vol. 63, No 17, pp. 1692-6, Sep 1991.
    • (1991) Anal Chem , vol.63 , Issue.17 , pp. 1692-1696
    • Bindra, D.S.1    Zhang, Y.2    Wilson, G.S.3    Sternberg, R.4    Thevenot, D.R.5    Moatti, D.6    Reach, G.7
  • 10
    • 0024950185 scopus 로고
    • The needle glucode electrode: In vitro performance and optimization for implantation
    • P Vadgama, J Spoors, L X Tang and C Battersby "The needle glucode electrode: In vitro performance and optimization for implantation,", Biomed. Biochem. Acta, 11/12, pp. 935-942, 1989.
    • (1989) Biomed. Biochem. Acta , vol.11-12 , pp. 935-942
    • Vadgama, P.1    Spoors, J.2    Tang, L.X.3    Battersby, C.4
  • 11
    • 84858477133 scopus 로고    scopus 로고
    • Gamry, Inc
    • Gamry, Inc., "LV500 Driver," ftp://gamry.com/LV500
    • LV500 Driver


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.