메뉴 건너뛰기




Volumn 4, Issue 5, 2004, Pages 568-575

Manipulation of microenvironment with a built-in electrochemical actuator in proximity of a dissolved oxygen microsensor

Author keywords

Electrolysis; Intelligent microsensor; Polyimide; Self calibration; Self diagnosis

Indexed keywords

ACTUATORS; ELECTROLYSIS; FUNCTIONS; INTEGRATION; MICROELECTRODES; OXYGEN; POLYIMIDES;

EID: 4544356245     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2004.832857     Document Type: Article
Times cited : (18)

References (20)
  • 1
    • 0022125833 scopus 로고
    • An ISEET-based microliter titrator: Integration of a chemical sensor-actuator system
    • B. H. van der Schoot and P. Bergveld, "An ISEET-based microliter titrator: integration of a chemical sensor-actuator system," Sens. Actuators, vol. 8, pp. 11-22, 1985.
    • (1985) Sens. Actuators , vol.8 , pp. 11-22
    • Van Der Schoot, B.H.1    Bergveld, P.2
  • 2
    • 0022681950 scopus 로고
    • Conlometric sensors: The application of a sensor-actuator system for long-term stability in chemical sensing
    • _, "Conlometric sensors: the application of a sensor-actuator system for long-term stability in chemical sensing," Sens. Actuators, vol. 13, pp. 251-262, 1988.
    • (1988) Sens. Actuators , vol.13 , pp. 251-262
  • 3
    • 0042441444 scopus 로고    scopus 로고
    • A new pH-ISFET based dissolved oxygen sensor by employing electrolysis of oxygen
    • B. K. Sohn and C. S. Kim, "A new pH-ISFET based dissolved oxygen sensor by employing electrolysis of oxygen," Sens. Actuators B, vol. 34, pp. 435-440, 1996.
    • (1996) Sens. Actuators B , vol.34 , pp. 435-440
    • Sohn, B.K.1    Kim, C.S.2
  • 7
    • 18544406945 scopus 로고    scopus 로고
    • Electrochemical time of flight flow sensor
    • J. Wu and W. Sansen, "Electrochemical time of flight flow sensor," Sens. Actuators B, vol. 97-98, pp. 68-74, 2002.
    • (2002) Sens. Actuators B , vol.97-98 , pp. 68-74
    • Wu, J.1    Sansen, W.2
  • 8
    • 0043030260 scopus 로고    scopus 로고
    • Multi-parameter detection of (bio-)chemical and physical quantities using an identical transducer principle
    • A. Poghossian, J. W. Schultze, and M. J. Schoning, "Multi-parameter detection of (bio-)chemical and physical quantities using an identical transducer principle," Sens. Actuators B, vol. 91, no. 1-3, pp. 83-91, 2003.
    • (2003) Sens. Actuators B , vol.91 , Issue.1-3 , pp. 83-91
    • Poghossian, A.1    Schultze, J.W.2    Schoning, M.J.3
  • 9
    • 0025227466 scopus 로고
    • PH-static enzyme sensor. Design of the pH control system
    • B. H. van der Schoot, H. Voorthuyzen, and P. Bergveld, "pH-static enzyme sensor. Design of the pH control system," Sens. Actuators B, vol. 1, no. 1-6, pp. 546-549, 1990.
    • (1990) Sens. Actuators B , vol.1 , Issue.1-6 , pp. 546-549
    • Van Der Schoot, B.H.1    Voorthuyzen, H.2    Bergveld, P.3
  • 10
    • 0031130431 scopus 로고    scopus 로고
    • ISFET glucose sensor based on a new principle using the electrolysis of hydrogen peroxide
    • H. I. Seo, C. S. Kim, B. K. Sohn, T. Yeow, M. T. Son, and M. Haskard, "ISFET glucose sensor based on a new principle using the electrolysis of hydrogen peroxide," Sens. Actuators B, vol. 40, pp. 1-5, 1997.
    • (1997) Sens. Actuators B , vol.40 , pp. 1-5
    • Seo, H.I.1    Kim, C.S.2    Sohn, B.K.3    Yeow, T.4    Son, M.T.5    Haskard, M.6
  • 15
    • 0027283749 scopus 로고
    • Thin-film Clark-type oxygen sensor based on novel polymer membrane systems for in-vivo and biosensor applications
    • G. Jobst, G. Urban, A. Jachimowicz, F. Kohl, O. Tilado, I. Letternbichler, and G. Nauer, "Thin-film Clark-type oxygen sensor based on novel polymer membrane systems for in-vivo and biosensor applications," Biosens. Bioelectron., vol. 8, pp. 123-128, 1993.
    • (1993) Biosens. Bioelectron. , vol.8 , pp. 123-128
    • Jobst, G.1    Urban, G.2    Jachimowicz, A.3    Kohl, F.4    Tilado, O.5    Letternbichler, I.6    Nauer, G.7
  • 18
    • 0025503255 scopus 로고
    • Problems associated with the miniaturization of a voltammetric oxygen sensor: Chemical crosstalk among electrodes
    • C. S. Cha, M. J. Shao, and C. C. Liu, "Problems associated with the miniaturization of a voltammetric oxygen sensor: chemical crosstalk among electrodes," Sens, Actuators B, vol. 2, pp. 239-242, 1990.
    • (1990) Sens, Actuators B , vol.2 , pp. 239-242
    • Cha, C.S.1    Shao, M.J.2    Liu, C.C.3
  • 20
    • 0000701749 scopus 로고    scopus 로고
    • An integrated micromachined electrochemical pump and dosing system
    • S. Bohm, W. Olthius, and P. Bergveld, "An integrated micromachined electrochemical pump and dosing system," J. Biomed. Microdevices, vol. 1, no. 2, pp. 121-130, 1999.
    • (1999) J. Biomed. Microdevices , vol.1 , Issue.2 , pp. 121-130
    • Bohm, S.1    Olthius, W.2    Bergveld, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.