메뉴 건너뛰기




Volumn 14, Issue 5, 2007, Pages 1065-1080

Diagnostic methods for outdoor polymeric insulators

Author keywords

Composite insulation; Fault diagnosis; Outdoor insulation

Indexed keywords

CONDUCTING POLYMERS; ELECTRIC FAULT LOCATION; ELECTRIC POTENTIAL; ELECTRIC POWER DISTRIBUTION; ELECTRIC POWER TRANSMISSION;

EID: 35348868824     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2007.4339466     Document Type: Review
Times cited : (176)

References (159)
  • 1
    • 77951567539 scopus 로고    scopus 로고
    • Composite insulators today: How this technology has been refined over the past 10 years and benefits to users
    • Hong Kong, China
    • R. S. Gorur, "Composite insulators today: How this technology has been refined over the past 10 years and benefits to users", in Proc. INMR, 2005 World & Exhibition on Insulators, Arresters & Bushings, Hong Kong, China, 2005.
    • (2005) Proc. INMR, 2005 World & Exhibition on Insulators, Arresters & Bushings
    • Gorur, R.S.1
  • 4
    • 77951546789 scopus 로고    scopus 로고
    • Experience with composite HVDC and HVAC insulators in China: From design to operation
    • Marbella, Spain
    • Xidong L, S. Wang, and F. Su, "Experience with composite HVDC and HVAC insulators in China: from design to operation", Proc. 2003 World Insulator Congress and Exhibition, pp. 15-22, Marbella, Spain, 2003.
    • (2003) Proc. 2003 World Insulator Congress and Exhibition , pp. 15-22
    • Xidong, L.1    Wang, S.2    Su, F.3
  • 5
    • 0032314703 scopus 로고    scopus 로고
    • A review of possible degradation mechanisms of silicone elastomers in high voltage insulation applications
    • Atlanta, GA, USA
    • J. L. Goudie, M. J. Owen, and T. Orbeck, "A review of possible degradation mechanisms of silicone elastomers in high voltage insulation applications", in Proc. IEEE Conf. on Electrical Insulation and Dielectric Phenomena, pp. 120-127, Atlanta, GA, USA, 1998.
    • (1998) Proc. IEEE Conf. on Electrical Insulation and Dielectric Phenomena , pp. 120-127
    • Goudie, J.L.1    Owen, M.J.2    Orbeck, T.3
  • 8
    • 20444418265 scopus 로고    scopus 로고
    • Resistance to brittle fracture of glass reinforced polymer composites used in composite (nonceramic) insulators
    • L. S. Kumosa, M. S. Kumosa, and D. L. Armentrout, "Resistance to brittle fracture of glass reinforced polymer composites used in composite (nonceramic) insulators", IEEE Trans. on Power Delivery, vol. 20 (4), pp. 2657-66, 2005.
    • (2005) IEEE Trans. on Power Delivery , vol.20 , Issue.4 , pp. 2657-2666
    • Kumosa, L.S.1    Kumosa, M.S.2    Armentrout, D.L.3
  • 12
    • 0008533255 scopus 로고    scopus 로고
    • Design & manufacturing of prototype insulators for installation at the Anneberg station
    • Stockholm, Sweden
    • T. G. Gustavsson and S. M. Gubanski, "Design & manufacturing of prototype insulators for installation at the Anneberg station", in Proc. Nordic Insulation Symp. (Nord-IS '01) pp. 289-298, Stockholm, Sweden, 2001.
    • (2001) Proc. Nordic Insulation Symp. (Nord-IS '01) , pp. 289-298
    • Gustavsson, T.G.1    Gubanski, S.M.2
  • 14
    • 6344284431 scopus 로고    scopus 로고
    • Moving from polymeric material to HV electrical apparatus with fully-integrated insulator - a case study
    • Shanghai, China
    • D. Windmar, "Moving from polymeric material to HV electrical apparatus with fully-integrated insulator - a case study", in Proc. 2001 World Insulator Congress and Exhibition, pp. 106-114, Shanghai, China, 2001.
    • (2001) Proc. 2001 World Insulator Congress and Exhibition , pp. 106-114
    • Windmar, D.1
  • 16
    • 0025432102 scopus 로고    scopus 로고
    • Cigré Working Group 22.03, Worldwide service experience with HV composite insulators, Electra, 130, pp. 67-77, 1990.
    • Cigré Working Group 22.03, "Worldwide service experience with HV composite insulators", Electra, vol. 130, pp. 67-77, 1990.
  • 17
    • 35348922367 scopus 로고    scopus 로고
    • Cigrè Working Group 22.03 (convener C. de Tourreil), Worldwide service experience with HV composite insulators, Electra, 191, pp. 27-43, August, 2000.
    • Cigrè Working Group 22.03 (convener C. de Tourreil), "Worldwide service experience with HV composite insulators", Electra, vol. 191, pp. 27-43, August, 2000.
  • 18
    • 35348856377 scopus 로고    scopus 로고
    • Innovative compact line design at Energie Ouest Suisse, Insulator News and Market Report, 7 (2), pp. 20-28, 1999.
    • "Innovative compact line design at Energie Ouest Suisse", Insulator News and Market Report, vol. 7 (2), pp. 20-28, 1999.
  • 19
    • 0031146068 scopus 로고    scopus 로고
    • Polymer outdoor insulating materials. Part I: Comparison of porcelain and polymer electrical insulation
    • J. Mackevich and M. Shah, "Polymer outdoor insulating materials. Part I: Comparison of porcelain and polymer electrical insulation", IEEE Electrical Insulation Magazine, vol. 13 (3), pp. 5-12, 1997.
    • (1997) IEEE Electrical Insulation Magazine , vol.13 , Issue.3 , pp. 5-12
    • Mackevich, J.1    Shah, M.2
  • 20
    • 0032667440 scopus 로고    scopus 로고
    • Composite insulators are gaining ground - 25 years of Swiss experience
    • USA
    • K. O. Papailiou, "Composite insulators are gaining ground - 25 years of Swiss experience", in Proc. 1999 IEEE Transmission and Distribution Conf., vol. 2, pp. 827-833, USA, 1999.
    • (1999) Proc. 1999 IEEE Transmission and Distribution Conf , vol.2 , pp. 827-833
    • Papailiou, K.O.1
  • 21
    • 6344293850 scopus 로고    scopus 로고
    • New compact composite insulation for environmental, economic and safety considerations
    • Shanghai, China
    • D. Dumora, "New compact composite insulation for environmental, economic and safety considerations", in Proc. 2001 World Insulator Congress and Exhibition, pp. 168-181, Shanghai, China, 2001.
    • (2001) Proc. 2001 World Insulator Congress and Exhibition , pp. 168-181
    • Dumora, D.1
  • 22
    • 0008846645 scopus 로고    scopus 로고
    • Assessing ten years of experience at Powerlink using new insulator technologies
    • Shanghai, China
    • B. Pokarier, "Assessing ten years of experience at Powerlink using new insulator technologies", in Proc. 2001 World Insulator Congress and Exhibition, pp. 11-19, Shanghai, China, 2001.
    • (2001) Proc. 2001 World Insulator Congress and Exhibition , pp. 11-19
    • Pokarier, B.1
  • 23
    • 6344276891 scopus 로고    scopus 로고
    • Utilization and service experience with composite insulators in Czech power system
    • Shanghai, China
    • V. Sklenicka and I. Zeman, "Utilization and service experience with composite insulators in Czech power system", in Proc. 2001 World Insulator Congress and Exhibition, pp. 309-323, Shanghai, China, 2001.
    • (2001) Proc. 2001 World Insulator Congress and Exhibition , pp. 309-323
    • Sklenicka, V.1    Zeman, I.2
  • 25
    • 0025505982 scopus 로고
    • Composite rod insulators for AC power lines: Electrical performance of various designs at a coastal testing station
    • R. G. Houlgate and D. A. Swift, "Composite rod insulators for AC power lines: electrical performance of various designs at a coastal testing station", IEEE Trans. on Power Delivery, vol. 5 (4), pp. 1944-55, 1990.
    • (1990) IEEE Trans. on Power Delivery , vol.5 , Issue.4 , pp. 1944-1955
    • Houlgate, R.G.1    Swift, D.A.2
  • 27
    • 0031125960 scopus 로고    scopus 로고
    • Outdoor polymeric insulators long-term exposed to HVDC
    • T. Sörqvist and A. E. Vlastós, "Outdoor polymeric insulators long-term exposed to HVDC", IEEE Trans. on Power Delivery, vol. 12 (2), pp. 1041-1048, 1997.
    • (1997) IEEE Trans. on Power Delivery , vol.12 , Issue.2 , pp. 1041-1048
    • Sörqvist, T.1    Vlastós, A.E.2
  • 28
    • 0026140347 scopus 로고
    • Surface structural changes of naturally aged silicone and EPDM insulators
    • A. E. Vlastós and S. M. Gubanski, "Surface structural changes of naturally aged silicone and EPDM insulators", IEEE Trans. on Power Delivery, pp. 888-900, 1991.
    • (1991) IEEE Trans. on Power Delivery , pp. 888-900
    • Vlastós, A.E.1    Gubanski, S.M.2
  • 29
    • 0007890322 scopus 로고
    • Influence of the hydrophobicity of outdoor insulators on the flashover voltage
    • Vaasa, Finland
    • A. Eriksson and D. Wikström, "Influence of the hydrophobicity of outdoor insulators on the flashover voltage", in Proc. Nordic Insulation Symp. (Nord-IS '94), pp. 39-51, Vaasa, Finland, 1994.
    • (1994) Proc. Nordic Insulation Symp. (Nord-IS '94) , pp. 39-51
    • Eriksson, A.1    Wikström, D.2
  • 30
    • 0029386428 scopus 로고
    • Flashover mechanism of silicone rubber insulators used for outdoor insulation - I
    • G. G. Karady, M. Shah, and R. L. Brown, "Flashover mechanism of silicone rubber insulators used for outdoor insulation - I", IEEE Trans. on Power Delivery, vol. 10 (4), pp. 1965-1971, 1995.
    • (1995) IEEE Trans. on Power Delivery , vol.10 , Issue.4 , pp. 1965-1971
    • Karady, G.G.1    Shah, M.2    Brown, R.L.3
  • 31
    • 0028754486 scopus 로고
    • Surface recovery of silicone rubber used for HV outdoor insulation
    • J. W. Chang and R. S. Gorur, "Surface recovery of silicone rubber used for HV outdoor insulation", IEEE Trans. on Dielectrics and Electrical Insulation, vol. 1 (6), pp. 1039-1046, 1994.
    • (1994) IEEE Trans. on Dielectrics and Electrical Insulation , vol.1 , Issue.6 , pp. 1039-1046
    • Chang, J.W.1    Gorur, R.S.2
  • 32
    • 0008531987 scopus 로고    scopus 로고
    • Loss and recovery of hydrophobicity of polydimethylsiloxane after exposure to electrical discharges
    • Ph.D Thesis, Department of Polymer Technology, Royal Institute of Technology, Stockholm, Sweden
    • H. Hillborg, "Loss and recovery of hydrophobicity of polydimethylsiloxane after exposure to electrical discharges", Ph.D Thesis, Department of Polymer Technology, Royal Institute of Technology, Stockholm, Sweden, 2001.
    • (2001)
    • Hillborg, H.1
  • 34
    • 0026238514 scopus 로고
    • Suppression mechanism of leakage current on RTV coated porcelain and silicone rubber insulators
    • S. H. Kim, E. A. Cherney, and R. Hackam, "Suppression mechanism of leakage current on RTV coated porcelain and silicone rubber insulators", IEEE Trans. on Power Delivery, vol. 6 (4), pp. 1549-1556, 1991.
    • (1991) IEEE Trans. on Power Delivery , vol.6 , Issue.4 , pp. 1549-1556
    • Kim, S.H.1    Cherney, E.A.2    Hackam, R.3
  • 35
    • 84910636467 scopus 로고
    • Wettability of naturally aged silicone and EDPM composite insulators
    • S. M. Gubanski and A. E. Vlastós, "Wettability of naturally aged silicone and EDPM composite insulators", IEEE Trans. on Power Delivery, vol. 5 (3), pp. 1527-35, 1990.
    • (1990) IEEE Trans. on Power Delivery , vol.5 , Issue.3 , pp. 1527-1535
    • Gubanski, S.M.1    Vlastós, A.E.2
  • 36
    • 33747438222 scopus 로고
    • The loss and recovery of hydrophobicity of RTV silicone rubber insulator coatings
    • S. H. Kim, E. A. Cherney, and R. Hackam, "The loss and recovery of hydrophobicity of RTV silicone rubber insulator coatings", IEEE Trans. on Power Delivery, vol. 5 (3), pp. 1491-1500, 1990.
    • (1990) IEEE Trans. on Power Delivery , vol.5 , Issue.3 , pp. 1491-1500
    • Kim, S.H.1    Cherney, E.A.2    Hackam, R.3
  • 37
    • 0035415153 scopus 로고    scopus 로고
    • Electrical and environmental stress and the hydrophobic stability of SIR, EVA and their blends
    • S. Kumagai and N. Yoshimura, "Electrical and environmental stress and the hydrophobic stability of SIR, EVA and their blends", IEEE Trans. on Dielectrics and Electrical Insulation, vol. 8 (4), pp. 679-686, 2001.
    • (2001) IEEE Trans. on Dielectrics and Electrical Insulation , vol.8 , Issue.4 , pp. 679-686
    • Kumagai, S.1    Yoshimura, N.2
  • 40
    • 0032318243 scopus 로고    scopus 로고
    • The effect of natural tropical climate to the surface properties of silicone rubber
    • Toyohashi, Japan
    • K. T. Sirait, Salama, Suwarno, and H. C. Kaemer, "The effect of natural tropical climate to the surface properties of silicone rubber", in Proc. Int. Symp. on Electrical Insulating Materials, pp. 453-456, Toyohashi, Japan, 1998.
    • (1998) Proc. Int. Symp. on Electrical Insulating Materials , pp. 453-456
    • Sirait, K.T.1    Salama, S.2    Kaemer, H.C.3
  • 41
    • 6344285536 scopus 로고
    • Outdoor Insulations
    • New Orleans, USA, Paper No. 30.01
    • th Int. Symp. on HV Eng. in New Orleans, USA, Paper No. 30.01, vol. 2, 1989.
    • (1989) th Int. Symp. on HV Eng , vol.2
    • Karady, G.G.1
  • 42
    • 0008823445 scopus 로고    scopus 로고
    • A conservative approach toward composite insulators at BC Hydro: Current factors and future considerations
    • Shanghai, China
    • J. H. Duxbury, "A conservative approach toward composite insulators at BC Hydro: Current factors and future considerations", in Proc. 2001 World Insulator Congress and Exhibition, pp. 83-89, Shanghai, China, 2001.
    • (2001) Proc. 2001 World Insulator Congress and Exhibition , pp. 83-89
    • Duxbury, J.H.1
  • 43
    • 35348835495 scopus 로고    scopus 로고
    • th Int. Symp. on HV Eng., 4, pp. 96-99, London, UK, 1999.
    • th Int. Symp. on HV Eng., vol. 4, pp. 96-99, London, UK, 1999.
  • 44
    • 0008861430 scopus 로고    scopus 로고
    • Faults of composite insulators in service and research of on-line detection method
    • London, UK
    • th Int. Symp. on HV Eng., vol. 4, pp. 208-211, London, UK, 1999.
    • (1999) th Int. Symp. on HV Eng , vol.4 , pp. 208-211
    • Su, F.1    Jia, Y.2
  • 45
    • 0031146938 scopus 로고    scopus 로고
    • Experience with IEC 1109 1000 h salt fog ageing test for composite insulators
    • I. Gutman, R. Hartings, R. Matsuoka, and K. Kondo, "Experience with IEC 1109 1000 h salt fog ageing test for composite insulators", IEEE Electrical Insulation Magazine, vol. 13 (3), pp. 36-39, 1997.
    • (1997) IEEE Electrical Insulation Magazine , vol.13 , Issue.3 , pp. 36-39
    • Gutman, I.1    Hartings, R.2    Matsuoka, R.3    Kondo, K.4
  • 46
    • 6344261749 scopus 로고    scopus 로고
    • Multifactor pollution testing to assess the long term performance of composite surge arresters and insulators
    • London, UK
    • th Int. Symp. on HV Eng., vol. 4, pp. 34-37, London, UK, 1999.
    • (1999) th Int. Symp. on HV Eng , vol.4 , pp. 34-37
    • Perrot, F.1
  • 47
    • 0032759627 scopus 로고    scopus 로고
    • Water drop corona effects on full-scale 500 kV non-ceramic insulators
    • A. J. Phillips, D. J. Childs, and H. M. Schneider, "Water drop corona effects on full-scale 500 kV non-ceramic insulators", IEEE Trans. on Power Delivery, vol. 14(1), pp. 258-265, 1999.
    • (1999) IEEE Trans. on Power Delivery , vol.14 , Issue.1 , pp. 258-265
    • Phillips, A.J.1    Childs, D.J.2    Schneider, H.M.3
  • 48
    • 0032636451 scopus 로고    scopus 로고
    • Ageing of non-ceramic insulators due to corona from water drops
    • A. J. Phillips, D. J. Childs, and H. M. Schneider, "Ageing of non-ceramic insulators due to corona from water drops", IEEE Trans. on Power Delivery, vol. 14(3), pp. 1081-1089, 1999.
    • (1999) IEEE Trans. on Power Delivery , vol.14 , Issue.3 , pp. 1081-1089
    • Phillips, A.J.1    Childs, D.J.2    Schneider, H.M.3
  • 50
    • 0029388463 scopus 로고
    • Flashover mechanism of silicone rubber insulators used for outdoor insulation - II
    • M. Shah, G. G. Karady, and R. L. Brown, "Flashover mechanism of silicone rubber insulators used for outdoor insulation - II", IEEE Trans, on Power Delivery, vol. 10 (4), pp. 1972-1978, 1995.
    • (1995) IEEE Trans, on Power Delivery , vol.10 , Issue.4 , pp. 1972-1978
    • Shah, M.1    Karady, G.G.2    Brown, R.L.3
  • 51
    • 0032651920 scopus 로고    scopus 로고
    • Time-load testing of nonceramic insulators with fiberglass core rod - a 20 year summary
    • New Orleans, USA
    • R. A. Bernstorf, "Time-load testing of nonceramic insulators with fiberglass core rod - a 20 year summary", in Proc. 1999 IEEE Transmission and Distribution Conf., vol. 2, pp. 823-826, New Orleans, USA, 1999.
    • (1999) Proc. 1999 IEEE Transmission and Distribution Conf , vol.2 , pp. 823-826
    • Bernstorf, R.A.1
  • 52
    • 33748318011 scopus 로고    scopus 로고
    • Analysis of the acid sources of a field brittle fractured composite insulator
    • L. Xidong and D. Jianjun, "Analysis of the acid sources of a field brittle fractured composite insulator", IEEE Trans. on Dielectrics and Electrical Insulation, vol. 13 (4), pp. 870-876, 2006.
    • (2006) IEEE Trans. on Dielectrics and Electrical Insulation , vol.13 , Issue.4 , pp. 870-876
    • Xidong, L.1    Jianjun, D.2
  • 54
    • 84954412024 scopus 로고    scopus 로고
    • Research on the brittle fracture of FRP rods and its acoustic emission detection
    • Singapore
    • L. Xidong, F. Ju, and C. Ling, "Research on the brittle fracture of FRP rods and its acoustic emission detection", in Proc. IEEE Power Eng. Soc. Winter Meeting, vol. 4, pp. 2812 -2816, Singapore, 2000.
    • (2000) Proc. IEEE Power Eng. Soc. Winter Meeting , vol.4 , pp. 2812-2816
    • Xidong, L.1    Ju, F.2    Ling, C.3
  • 55
    • 0035307014 scopus 로고    scopus 로고
    • FRP rods for brittle fracture resistant composite insulators
    • M. Kuhl, "FRP rods for brittle fracture resistant composite insulators", IEEE Trans. on Dielectrics and Electrical Insulation, vol. 8 (4), pp. 181-190, 2001.
    • (2001) IEEE Trans. on Dielectrics and Electrical Insulation , vol.8 , Issue.4 , pp. 181-190
    • Kuhl, M.1
  • 56
    • 20444398781 scopus 로고    scopus 로고
    • Failure analyses of nonceramic insulators. Part 1: Brittle fracture characteristics
    • M. Kumosa, L. Kumosa, and D. Armentrout, "Failure analyses of nonceramic insulators. Part 1: Brittle fracture characteristics", IEEE Electrical Insulation Magazine, vol. 21 (3), pp. 14-27, 2005.
    • (2005) IEEE Electrical Insulation Magazine , vol.21 , Issue.3 , pp. 14-27
    • Kumosa, M.1    Kumosa, L.2    Armentrout, D.3
  • 57
    • 20444372047 scopus 로고    scopus 로고
    • Failure analyses of nonceramic insulators: Part II - The brittle fracture model and failure prevention
    • M. S. Kumosa, L. S. Kumosa, and D. L. Armentrout, "Failure analyses of nonceramic insulators: Part II - The brittle fracture model and failure prevention", IEEE Electrical Insulation Magazine, vol. 21 (4), pp. 28-41, 2005.
    • (2005) IEEE Electrical Insulation Magazine , vol.21 , Issue.4 , pp. 28-41
    • Kumosa, M.S.1    Kumosa, L.S.2    Armentrout, D.L.3
  • 58
    • 35348854489 scopus 로고    scopus 로고
    • Factor to take into account when using composite insulators: The experience at one utility, Insulator News and Market Report, 12(1), pp. 18-25, 2004.
    • "Factor to take into account when using composite insulators: The experience at one utility", Insulator News and Market Report, vol. 12(1), pp. 18-25, 2004.
  • 59
    • 35348836672 scopus 로고    scopus 로고
    • Experience with non-ceramic bushings at Florida-based utility, Insulator News and Market Report, 5 (6), pp. 30-35, 1997.
    • "Experience with non-ceramic bushings at Florida-based utility", Insulator News and Market Report, vol. 5 (6), pp. 30-35, 1997.
  • 60
    • 6344254616 scopus 로고    scopus 로고
    • Some recommendations on the handling of composite insulators
    • Barcelona, Spain
    • C. de Tourreil, "Some recommendations on the handling of composite insulators", in Proc. Insulator 2000 World Congress, pp. 278-287, Barcelona, Spain, 1999.
    • (1999) Proc. Insulator 2000 World Congress , pp. 278-287
    • de Tourreil, C.1
  • 61
    • 35348813199 scopus 로고    scopus 로고
    • Cigré Working Group 22.03 (convener C. de Tourreil), Composite insulators handling guide, Electra, number 195, April, pp. 50-53, 2001.
    • Cigré Working Group 22.03 (convener C. de Tourreil), "Composite insulators handling guide", Electra, number 195, April, pp. 50-53, 2001.
  • 62
    • 6344238826 scopus 로고    scopus 로고
    • FCI Furukawa's solution for the third millennium: Enhancement in reliability of non-ceramic insulators
    • Shanghai, China
    • A. Bognar, A. Janko, E. Kreskay, and P. Szaplonczay, "FCI Furukawa's solution for the third millennium: Enhancement in reliability of non-ceramic insulators", in Proc. 2001 World Insulator Congress and Exhibition, pp. 265-277, Shanghai, China, 2001.
    • (2001) Proc. 2001 World Insulator Congress and Exhibition , pp. 265-277
    • Bognar, A.1    Janko, A.2    Kreskay, E.3    Szaplonczay, P.4
  • 63
    • 0031257359 scopus 로고    scopus 로고
    • Gunshot damage to ceramic and nonceramic insulators
    • J. T. Burnham and R. J. Waidelich, "Gunshot damage to ceramic and nonceramic insulators", IEEE Trans. on Power Delivery, vol. 12 (4), pp. 1651-1656, 1997.
    • (1997) IEEE Trans. on Power Delivery , vol.12 , Issue.4 , pp. 1651-1656
    • Burnham, J.T.1    Waidelich, R.J.2
  • 65
    • 6344267187 scopus 로고    scopus 로고
    • Investigation of bird streamer fiashovers at 400 kV overhead transmission line composite insulator sets
    • Delft, Netherlands
    • th Int. Symp. on HV Eng. Delft, Netherlands, 2003.
    • (2003) th Int. Symp. on HV Eng
    • Seifert, J.M.1
  • 67
    • 0008840084 scopus 로고    scopus 로고
    • Current experience with and future applications for composite insulator at Transgrid
    • Shanghai, China
    • S. Hodgkinson, "Current experience with and future applications for composite insulator at Transgrid", in Proc. 2001 World Insulator Congress and Exhibition pp. 63-70, Shanghai, China, 2001.
    • (2001) Proc. 2001 World Insulator Congress and Exhibition , pp. 63-70
    • Hodgkinson, S.1
  • 68
    • 6344287420 scopus 로고    scopus 로고
    • Experience with composite insulators installed on the transmission lines of Red Eléctrica de España. Laboratory tests and field inspection techniques
    • Barcelona, Spain
    • L. J. Fernández, J. M. Muñoz, and R. García, "Experience with composite insulators installed on the transmission lines of Red Eléctrica de España. Laboratory tests and field inspection techniques", in Proc. Insulator 2000 World Congress, pp. 331-341, Barcelona, Spain, 1999.
    • (1999) Proc. Insulator 2000 World Congress , pp. 331-341
    • Fernández, L.J.1    Muñoz, J.M.2    García, R.3
  • 69
    • 35348898473 scopus 로고    scopus 로고
    • Research findings comparing performance of different insulator designs on distribution lines in tropical environments, Insulator News and Market Report, 7 (6), pp. 46-53, 1999.
    • "Research findings comparing performance of different insulator designs on distribution lines in tropical environments", Insulator News and Market Report, vol. 7 (6), pp. 46-53, 1999.
  • 70
    • 35348821300 scopus 로고    scopus 로고
    • Research at Chalmers focusing and promoting developments in outdoor electrical insulation, Insulator News and Market Report, 8 (2), pp. 28-36, 2000.
    • "Research at Chalmers focusing and promoting developments in outdoor electrical insulation", Insulator News and Market Report, vol. 8 (2), pp. 28-36, 2000.
  • 71
    • 35348822555 scopus 로고    scopus 로고
    • Growing interest at Energy to assess techniques for in service monitoring of composite insulators, Insulator News and Market Report, 7 (2), pp. 30-34, 1999.
    • "Growing interest at Energy to assess techniques for in service monitoring of composite insulators", Insulator News and Market Report, vol. 7 (2), pp. 30-34, 1999.
  • 72
    • 0033702944 scopus 로고    scopus 로고
    • Performance of nonceramic insulators under tropical field conditions
    • M. A. R. M. Fernando and S. M. Gubanski, "Performance of nonceramic insulators under tropical field conditions", IEEE Transactions on Power Delivery, vol. 15 (1), pp. 355-360, 2000.
    • (2000) IEEE Transactions on Power Delivery , vol.15 , Issue.1 , pp. 355-360
    • Fernando, M.A.R.M.1    Gubanski, S.M.2
  • 73
    • 27144498279 scopus 로고    scopus 로고
    • Field and laboratory aging of polymeric distribution cable terminations. I. Field aging
    • R. S. Gorur and B. S. Bernstein, "Field and laboratory aging of polymeric distribution cable terminations. I. Field aging", IEEE Trans, on Power Delivery, vol. 13 (2), pp. 316-322, 1998.
    • (1998) IEEE Trans, on Power Delivery , vol.13 , Issue.2 , pp. 316-322
    • Gorur, R.S.1    Bernstein, B.S.2
  • 75
    • 0037399102 scopus 로고    scopus 로고
    • Mold growth on nonceramic insulators and its impact on electrical performance
    • R. S. Gorur, J. Montesinos, R. Roberson, J. Burnham, and R. Hill, "Mold growth on nonceramic insulators and its impact on electrical performance", IEEE Trans. on Power Delivery, vol. 18 (2), pp. 559-563, 2003.
    • (2003) IEEE Trans. on Power Delivery , vol.18 , Issue.2 , pp. 559-563
    • Gorur, R.S.1    Montesinos, J.2    Roberson, R.3    Burnham, J.4    Hill, R.5
  • 79
    • 0031186985 scopus 로고    scopus 로고
    • A study of biological contaminants on high voltage porcelain insulators
    • R. D. McAfee, R. D. Heaton, J. M. King, and A. U. Falster, "A study of biological contaminants on high voltage porcelain insulators", Electric Power Systems Research, vol. 42 (1), pp. 35-39, 1997.
    • (1997) Electric Power Systems Research , vol.42 , Issue.1 , pp. 35-39
    • McAfee, R.D.1    Heaton, R.D.2    King, J.M.3    Falster, A.U.4
  • 80
    • 34250880264 scopus 로고
    • Performance evaluation of 15 kV polymeric insulators for dead-end type applications on distribution systems
    • G. B. Rackliffe, R. E. Lee, D. E. Fritz, and R. W. Harmon, "Performance evaluation of 15 kV polymeric insulators for dead-end type applications on distribution systems", IEEE Trans. on Power Delivery, vol. 4 (2), pp. 1223-31, 1989.
    • (1989) IEEE Trans. on Power Delivery , vol.4 , Issue.2 , pp. 1223-1231
    • Rackliffe, G.B.1    Lee, R.E.2    Fritz, D.E.3    Harmon, R.W.4
  • 81
    • 0024144989 scopus 로고
    • Discharge characteristics of alga-contaminated string insulators in the tropics
    • F. Coowar and P. R. P. Hoole, "Discharge characteristics of alga-contaminated string insulators in the tropics", Electric Power System Research, vol. 5 (3), pp. 215-218, 1988.
    • (1988) Electric Power System Research , vol.5 , Issue.3 , pp. 215-218
    • Coowar, F.1    Hoole, P.R.P.2
  • 82
    • 0039205176 scopus 로고    scopus 로고
    • K. a. M. Naito, R. and K. Sakanishi, Investigations of the insulator performance of the insulator covered with lichen, IEEE Trans. on Power Delivery, 5 (3), pp. 1634-1640, 1990.
    • K. a. M. Naito, R. and K. Sakanishi, "Investigations of the insulator performance of the insulator covered with lichen", IEEE Trans. on Power Delivery, vol. 5 (3), pp. 1634-1640, 1990.
  • 83
    • 38249005206 scopus 로고    scopus 로고
    • Mould fungus growth on sanitary sealants
    • A. Wolf, "Mould fungus growth on sanitary sealants", Construction and building materials, vol. 3, pp. 145-151, 1998.
    • (1998) Construction and building materials , vol.3 , pp. 145-151
    • Wolf, A.1
  • 84
    • 35348883710 scopus 로고    scopus 로고
    • One utility's experience with mold growth on silicone bushings, Insulator News and Market Report, 12(1), pp. 68-73, 2004.
    • "One utility's experience with mold growth on silicone bushings", Insulator News and Market Report, vol. 12(1), pp. 68-73, 2004.
  • 85
    • 35348894485 scopus 로고    scopus 로고
    • New laser technique for diagnostics of composite insulators
    • Insulator News and Market Report
    • "New laser technique for diagnostics of composite insulators", Insulator News and Market Report, vol. 12, pp. 78-83, 2004.
    • (2004) , vol.12 , pp. 78-83
  • 86
    • 35348837311 scopus 로고    scopus 로고
    • Mold growth on composite insulators: A real problem or simply a cosmetic issue?, Insulator News and Market Report, 11 (6), pp. 36-42, 2003.
    • "Mold growth on composite insulators: A real problem or simply a cosmetic issue?", Insulator News and Market Report, vol. 11 (6), pp. 36-42, 2003.
  • 87
    • 35348849576 scopus 로고    scopus 로고
    • Japanese utility studies composite insulators at long-term test station, Insulator News and Market Report, 12 (2), pp. 26-32, 2004.
    • "Japanese utility studies composite insulators at long-term test station", Insulator News and Market Report, vol. 12 (2), pp. 26-32, 2004.
  • 91
    • 3042647452 scopus 로고    scopus 로고
    • Biofilms on silicone rubber insulators; microbial composition and diagnostics of removal by use of ESEM/EDS
    • S. Wallström and S. Karlsson, "Biofilms on silicone rubber insulators; microbial composition and diagnostics of removal by use of ESEM/EDS.", Polymer Degradation and Stability, vol. 85 (2), pp. 841-846, 2004.
    • (2004) Polymer Degradation and Stability , vol.85 , Issue.2 , pp. 841-846
    • Wallström, S.1    Karlsson, S.2
  • 92
    • 0031599413 scopus 로고    scopus 로고
    • Relevance of biofilms for the biodeterioration of surfaces of polymeric materials
    • H.-C. Flemming, "Relevance of biofilms for the biodeterioration of surfaces of polymeric materials", Polymer Degradation and Stability, vol. 59 (1), pp. 309-315, 1998.
    • (1998) Polymer Degradation and Stability , vol.59 , Issue.1 , pp. 309-315
    • Flemming, H.-C.1
  • 93
    • 19144366150 scopus 로고    scopus 로고
    • Microbiological growth testing of polymeric materials: An evaluation of new methods
    • S. Wallström, E. Stromberg, and S. Karlsson, "Microbiological growth testing of polymeric materials: An evaluation of new methods", Polymer Testing, vol. 24 (5), pp. 557-563, 2005.
    • (2005) Polymer Testing , vol.24 , Issue.5 , pp. 557-563
    • Wallström, S.1    Stromberg, E.2    Karlsson, S.3
  • 94
    • 6344223098 scopus 로고
    • Electrochemical and microbiological phenomena during accelerated ageing tests of polymeric insulators
    • Yokohama, Japan
    • th Int. Symp. on HV Eng., vol. 2, pp. 25-28, Yokohama, Japan, 1993.
    • (1993) th Int. Symp. on HV Eng , vol.2 , pp. 25-28
    • Schmuck, F.1    Bärsch, R.2
  • 95
    • 6344267189 scopus 로고    scopus 로고
    • Microbiological growth testing on silicon rubber materials for outdoor high voltage insulation
    • S. Wallström, K. Dowling, and S. Karlsson, "Microbiological growth testing on silicon rubber materials for outdoor high voltage insulation", Polymer Preprints, vol. 42 (1), pp. 430-431, 2001.
    • (2001) Polymer Preprints , vol.42 , Issue.1 , pp. 430-431
    • Wallström, S.1    Dowling, K.2    Karlsson, S.3
  • 98
    • 34548859482 scopus 로고    scopus 로고
    • Optimized use of HV composite apparatus insulators: Field experience from coastal and inland test stations
    • I. Gutman, D. Windmar, D. Gustavsson, L. Stenström, and W. L. Vosloo, "Optimized use of HV composite apparatus insulators: field experience from coastal and inland test stations", CIGRE Session 2004, A3-104, 2004.
    • (2004) CIGRE Session 2004
    • Gutman, I.1    Windmar, D.2    Gustavsson, D.3    Stenström, L.4    Vosloo, W.L.5
  • 99
    • 35348906820 scopus 로고    scopus 로고
    • Today's operating performance and manufacturing processing requirements for silicone rubber in electrical components
    • Hong Kong, November 27-30
    • D. Windmar and H. Hillborg, "Today's operating performance and manufacturing processing requirements for silicone rubber in electrical components ", in Proc. INMR, 2005 World & Exhibition on Insulators, Arresters & Bushings, Hong Kong, November 27-30 2005, 2005.
    • (2005) Proc. INMR, 2005 World & Exhibition on Insulators, Arresters & Bushings
    • Windmar, D.1    Hillborg, H.2
  • 104
    • 6344219669 scopus 로고    scopus 로고
    • Technical diagnostics, non-destructive state-estimation instead of damaging voltage test
    • Montreal, Canada
    • th Int. Conf. on HV Eng., pp. 405-408, Montreal, Canada, 1997.
    • (1997) th Int. Conf. on HV Eng , pp. 405-408
    • Porzel, R.1    Muhr, M.2
  • 105
    • 35348901458 scopus 로고    scopus 로고
    • Cigré Working Group 22.03 (convener C. de Tourreil), Review of 'in service diagnostic testing' of composite insulators, Electra, 169, pp. 105-119, December, 1996.
    • Cigré Working Group 22.03 (convener C. de Tourreil), "Review of 'in service diagnostic testing' of composite insulators", Electra, vol. 169, pp. 105-119, December, 1996.
  • 106
    • 6344243146 scopus 로고    scopus 로고
    • Status of inspection techniques to assess the condition of non-ceramic insulators in service
    • Barcelona, Spain
    • C. de Tourreil, "Status of inspection techniques to assess the condition of non-ceramic insulators in service", in Proc. Insulator 2000 World Congress, pp. 222-230, Barcelona, Spain, 1999.
    • (1999) Proc. Insulator 2000 World Congress , pp. 222-230
    • de Tourreil, C.1
  • 107
    • 6344254616 scopus 로고    scopus 로고
    • Some recommendations on the handling of composite insulators
    • World Congress, pp
    • C. de Tourreil, "Some recommendations on the handling of composite insulators", in Proc. Insulator 2000 World Congress, pp. 278-287, 2001.
    • (2000) Proc. Insulator , pp. 278-287
    • de Tourreil, C.1
  • 108
    • 35348842778 scopus 로고    scopus 로고
    • Research project aims to qualify in-service techniques to detect impending failures on non-ceramic insulators, Insulator News and Market Report, 6 (4), pp. 64-67, 1998.
    • "Research project aims to qualify in-service techniques to detect impending failures on non-ceramic insulators", Insulator News and Market Report, vol. 6 (4), pp. 64-67, 1998.
  • 109
    • 35348872621 scopus 로고    scopus 로고
    • Composite insulators past, present & future, Insulator News and Market Report, 12(1), pp. 42-43, 2004.
    • "Composite insulators past, present & future", Insulator News and Market Report, vol. 12(1), pp. 42-43, 2004.
  • 110
    • 6344293848 scopus 로고    scopus 로고
    • The future of testing insulators: What will be required
    • Shanghai, China
    • C. de Tourreil, "The future of testing insulators: What will be required", in Proc. 2001 World Insulator Congress and Exhibition pp. 278-287, Shanghai, China, 2001.
    • (2001) Proc. 2001 World Insulator Congress and Exhibition , pp. 278-287
    • de Tourreil, C.1
  • 111
    • 0031122050 scopus 로고    scopus 로고
    • Electrical test methods for non-ceramic insulators used for live line replacement
    • R. W. Harmon, G. G. Karady, and O. G. Amburgey, "Electrical test methods for non-ceramic insulators used for live line replacement", IEEE Trans. on Power Delivery, vol. 12 (2), pp. 965-970, 1997.
    • (1997) IEEE Trans. on Power Delivery , vol.12 , Issue.2 , pp. 965-970
    • Harmon, R.W.1    Karady, G.G.2    Amburgey, O.G.3
  • 112
    • 6344282464 scopus 로고    scopus 로고
    • New comprehensive test methods and insulation diagnoses of high voltage insulating composites and tools
    • Montreal, Québec Canada
    • th Int. Symp. on HV Eng., vol. 4, pp. 63-66, Montreal, Québec Canada, 1997.
    • (1997) th Int. Symp. on HV Eng , vol.4 , pp. 63-66
    • Tian, Z.1    Feng, Y.2    Chen, R.3
  • 113
    • 0000041440 scopus 로고    scopus 로고
    • Experience with the detection of faulty composite insulators on high-voltage power lines by the electric field measurement method
    • G. H. Vaillancourt, S. Carignan, and C. Jean, "Experience with the detection of faulty composite insulators on high-voltage power lines by the electric field measurement method", IEEE Trans. on Power Delivery, vol. 13 (2), pp. 661-666, 1998.
    • (1998) IEEE Trans. on Power Delivery , vol.13 , Issue.2 , pp. 661-666
    • Vaillancourt, G.H.1    Carignan, S.2    Jean, C.3
  • 119
    • 35348892722 scopus 로고    scopus 로고
    • The design and evaluation of a multi-spectral imaging camera for the inspection of transmission lines and substations equipment
    • China
    • R. Stolper, J. Hart, and N. Mahatho, "The design and evaluation of a multi-spectral imaging camera for the inspection of transmission lines and substations equipment", in Proc. 2005 World Insulator Congress and Exhibition in Hong Kong, China, 2005.
    • (2005) Proc. 2005 World Insulator Congress and Exhibition in Hong Kong
    • Stolper, R.1    Hart, J.2    Mahatho, N.3
  • 120
    • 35348888466 scopus 로고    scopus 로고
    • Spanish utility embarks on program for on-line inspections of non-ceramic insulators, Insulator News and Market Report, 5 (6), pp. 12-20, 1997.
    • "Spanish utility embarks on program for on-line inspections of non-ceramic insulators", Insulator News and Market Report, vol. 5 (6), pp. 12-20, 1997.
  • 122
    • 6344235136 scopus 로고    scopus 로고
    • In service diagnostic of composite insulators EDF's test results
    • Montréal, Québec, Canada
    • th Int. Symp. on HV Eng., vol. 4, pp. 139-142, Montréal, Québec, Canada, 1997.
    • (1997) th Int. Symp. on HV Eng , vol.4 , pp. 139-142
    • Spangenberg, E.1    Riquel, G.2
  • 123
    • 35348826202 scopus 로고    scopus 로고
    • Personal communication with Håkan Wieek at STRI AB, Sweden
    • A. Dernfalk, Personal communication with Håkan Wieek at STRI AB, Sweden, 2002.
    • (2002)
    • Dernfalk, A.1
  • 125
    • 0031639068 scopus 로고    scopus 로고
    • Acoustic method for quality control and in-service periodic monitoring of medium voltage cable terminations
    • Arlington, Virgina, USA
    • L. E. Lundgaard and W. Hansen, "Acoustic method for quality control and in-service periodic monitoring of medium voltage cable terminations", in Proc. 1998 IEEE Int. Symp. on Electrical Insulation, vol. 1, pp. 130-133, Arlington, Virgina, USA, 1998.
    • (1998) Proc. 1998 IEEE Int. Symp. on Electrical Insulation , vol.1 , pp. 130-133
    • Lundgaard, L.E.1    Hansen, W.2
  • 127
    • 0028555734 scopus 로고    scopus 로고
    • A. J. McGrail, D. W. Auckland, and B. R. Varlow, Detecting and classifying flaws within insulating materials using ultrasound, in Proc. 1994 IEEE Int. Symp. on Electrical Insulation, pp. 22-24, Pittsburgh, PA, USA, 1994.
    • A. J. McGrail, D. W. Auckland, and B. R. Varlow, "Detecting and classifying flaws within insulating materials using ultrasound", in Proc. 1994 IEEE Int. Symp. on Electrical Insulation, pp. 22-24, Pittsburgh, PA, USA, 1994.
  • 128
    • 0028408586 scopus 로고    scopus 로고
    • T. McGrail, Ultrasonic NDT for defects/degradation in insulation, in Proc. IEE Colloquium on Characterisation of Dielectric Materials: a Review, pp. 1/1-5, London, UK, 1994.
    • T. McGrail, "Ultrasonic NDT for defects/degradation in insulation", in Proc. IEE Colloquium on Characterisation of Dielectric Materials: a Review, pp. 1/1-5, London, UK, 1994.
  • 130
    • 0030407086 scopus 로고    scopus 로고
    • Comparison between scanning acoustic microscopy and submillimeter spectroscopy - A new opportunity to investigate dielectric behavior and structure of materials
    • San Francisco, USA
    • R. G. Maev, V. M. Levin, E. Y. Maeva, A. A. Volkov, G. V. Kozlov, Y. G. Goncharov, and B. P. Gorshunov, "Comparison between scanning acoustic microscopy and submillimeter spectroscopy - A new opportunity to investigate dielectric behavior and structure of materials", in Proc. IEEE Conf. on Electrical Insulation and Dielectric Phenomena, vol. 2, pp. 554-556, San Francisco, USA, 1996.
    • (1996) Proc. IEEE Conf. on Electrical Insulation and Dielectric Phenomena , vol.2 , pp. 554-556
    • Maev, R.G.1    Levin, V.M.2    Maeva, E.Y.3    Volkov, A.A.4    Kozlov, G.V.5    Goncharov, Y.G.6    Gorshunov, B.P.7
  • 131
    • 0026157287 scopus 로고
    • Nondestructive evaluation of materials with the scanning laser acoustic microscope
    • M. Oishi, "Nondestructive evaluation of materials with the scanning laser acoustic microscope", IEEE Electrical Insulation Magazine, vol. 7 (3), pp. 25-30, 1991.
    • (1991) IEEE Electrical Insulation Magazine , vol.7 , Issue.3 , pp. 25-30
    • Oishi, M.1
  • 132
    • 0028375552 scopus 로고
    • High-humidity deterioration and internal structure change of epoxy resin for electrical insulation
    • T. Kumazawa, M. Oishi, and M. Todoki, "High-humidity deterioration and internal structure change of epoxy resin for electrical insulation", IEEE Trans. on Dielectrics and Electrical Insulation, vol. 1 (1), 1994.
    • (1994) IEEE Trans. on Dielectrics and Electrical Insulation , vol.1 , Issue.1
    • Kumazawa, T.1    Oishi, M.2    Todoki, M.3
  • 133
    • 33847745361 scopus 로고    scopus 로고
    • Resolution evaluation of ultrasonic diagnostic tools for electrical insulation devices and the detection of electrical trees
    • H. Ueno, P. Walter, C. Cornelissen, and A. Schnettler, "Resolution evaluation of ultrasonic diagnostic tools for electrical insulation devices and the detection of electrical trees", IEEE Trans. on Dielectrics and Electrical Insulation, vol. 14 (1), pp. 249-256, 2007.
    • (2007) IEEE Trans. on Dielectrics and Electrical Insulation , vol.14 , Issue.1 , pp. 249-256
    • Ueno, H.1    Walter, P.2    Cornelissen, C.3    Schnettler, A.4
  • 134
    • 34249715785 scopus 로고    scopus 로고
    • Online Detecting Composite Insulators By Two Dimensions Electric Field Distribution
    • Toronto, Canada
    • C. Yangchun and L. Chengrong, "Online Detecting Composite Insulators By Two Dimensions Electric Field Distribution", in Proc. of the 2006 IEEE Int. Symp. on Electrical Insulation, pp. 132-135, Toronto, Canada, 2006,.
    • (2006) Proc. of the 2006 IEEE Int. Symp. on Electrical Insulation , pp. 132-135
    • Yangchun, C.1    Chengrong, L.2
  • 139
    • 0034512808 scopus 로고    scopus 로고
    • Image analysis of hydrophobicity of polymer insulators by observing at microscopic area
    • Victoria, BC, Canada
    • T. Tokoro, M. Nagao, and M. Kosaki, "Image analysis of hydrophobicity of polymer insulators by observing at microscopic area", in Proc. IEEE Conf. on Electrical Insulation and Dielectric Phenomena, vol. 1, pp. 226-229, Victoria, BC, Canada, 2000.
    • (2000) Proc. IEEE Conf. on Electrical Insulation and Dielectric Phenomena , vol.1 , pp. 226-229
    • Tokoro, T.1    Nagao, M.2    Kosaki, M.3
  • 145
    • 35348883709 scopus 로고    scopus 로고
    • Image analysis in insulator diagnostics
    • Insulator News and Market Report
    • "Image analysis in insulator diagnostics", Insulator News and Market Report, vol. 12, pp. 36-40, 2004.
    • (2004) , vol.12 , pp. 36-40
  • 148
    • 0035760836 scopus 로고    scopus 로고
    • Thermosonics: Detecting cracks and adhesion defects using ultrasonic excitation and infrared imaging
    • X. Han, Z. Ouyang, L. D. Favro, and R. L. Thomas, "Thermosonics: Detecting cracks and adhesion defects using ultrasonic excitation and infrared imaging", Journal of Adhesion, vol. 76 (2), pp. 151-162, 2001.
    • (2001) Journal of Adhesion , vol.76 , Issue.2 , pp. 151-162
    • Han, X.1    Ouyang, Z.2    Favro, L.D.3    Thomas, R.L.4
  • 150
    • 15344350422 scopus 로고    scopus 로고
    • IR self-referencing thermography for detection of in-depth defects, Infrared Phys
    • M. Omar, M. I. Hassan, K. Saito, and R. Alloo, "IR self-referencing thermography for detection of in-depth defects", Infrared Phys. Technology, vol. 46 (4), pp. 283 - 289, 2005.
    • (2005) Technology , vol.46 , Issue.4 , pp. 283-289
    • Omar, M.1    Hassan, M.I.2    Saito, K.3    Alloo, R.4
  • 151
    • 33646095198 scopus 로고    scopus 로고
    • On the ultrasonic assessment of adhesion between polymer coating and concrete substrate
    • L. Czarnecki, A. Garbacz, and M. Krystosiak, "On the ultrasonic assessment of adhesion between polymer coating and concrete substrate", Cement and Concrete Composites, vol. 28 (4), pp. 360 - 369, 2006.
    • (2006) Cement and Concrete Composites , vol.28 , Issue.4 , pp. 360-369
    • Czarnecki, L.1    Garbacz, A.2    Krystosiak, M.3
  • 153
    • 0027694570 scopus 로고    scopus 로고
    • A. McGrail, A. Risino, D. W. Auckland, and B. R. Varlow, Use of a medical ultrasonic scanner for the inspection of high voltage insulation, IEEE Electrical Insulation Magazine, 9 (6), pp. 5-10, 1993.
    • A. McGrail, A. Risino, D. W. Auckland, and B. R. Varlow, "Use of a medical ultrasonic scanner for the inspection of high voltage insulation", IEEE Electrical Insulation Magazine, vol. 9 (6), pp. 5-10, 1993.
  • 157
    • 0025521465 scopus 로고
    • Ultrasonic detection of insulation degradation
    • IEE Proceedings: Physical Science, Measurement and Instrumentation, Management and Education
    • D. W. Auckland, B. R. Varlow, and D. Maloney, "Ultrasonic detection of insulation degradation", IEE Proceedings: Physical Science, Measurement and Instrumentation, Management and Education, Reviews, vol. 137 (6), pp. 356-360, 1990.
    • (1990) Reviews , vol.137 , Issue.6 , pp. 356-360
    • Auckland, D.W.1    Varlow, B.R.2    Maloney, D.3
  • 159
    • 0034544958 scopus 로고    scopus 로고
    • Evaluating the soundness of bonding using shearography
    • Y. Y. Hung, W. D. Luo, L. Lin, and H. M. Shang, "Evaluating the soundness of bonding using shearography", Composite Structures, vol. 50 (4), pp. 353-362, 2000.
    • (2000) Composite Structures , vol.50 , Issue.4 , pp. 353-362
    • Hung, Y.Y.1    Luo, W.D.2    Lin, L.3    Shang, H.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.