메뉴 건너뛰기




Volumn 52, Issue 4, 2007, Pages 325-330

Piezoelectric immunosensor for the direct and rapid detection of francisella tularensis

Author keywords

[No Author keywords available]

Indexed keywords

BACTERIUM ANTIBODY;

EID: 35348850219     PISSN: 00155632     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02932086     Document Type: Article
Times cited : (30)

References (21)
  • 3
    • 8444244790 scopus 로고    scopus 로고
    • Multiplex diagnostic platforms for detection of biothreat agents
    • CIRINO N.M., MUSSER K.A., EGAN C.: Multiplex diagnostic platforms for detection of biothreat agents. Expert Rev.Mol.Diagn. 4, 841-857 (2004).
    • (2004) Expert Rev.Mol.Diagn , vol.4 , pp. 841-857
    • CIRINO, N.M.1    MUSSER, K.A.2    EGAN, C.3
  • 4
    • 0035816032 scopus 로고    scopus 로고
    • DENNIS D.T., IGLESBY T.V., HENDERSON D.A., BARTLETT J.G., ASCHER M.S., EITZEN E., FINE A.D., FRIEDLANDER A.M., HAUER J., LAYTON M., LILLIBRIDGE S.R., MCDADE J.E., OSTERHOLM M.T., O'TOOLE T., PARKER G., PERL T.M., RUSSELL P.K., TONAT K.: Tularemia as a biological weapon - medical and public health management. J.Am.Med.Assoc. 285, 2763-2773 (2001).
    • DENNIS D.T., IGLESBY T.V., HENDERSON D.A., BARTLETT J.G., ASCHER M.S., EITZEN E., FINE A.D., FRIEDLANDER A.M., HAUER J., LAYTON M., LILLIBRIDGE S.R., MCDADE J.E., OSTERHOLM M.T., O'TOOLE T., PARKER G., PERL T.M., RUSSELL P.K., TONAT K.: Tularemia as a biological weapon - medical and public health management. J.Am.Med.Assoc. 285, 2763-2773 (2001).
  • 6
    • 33644532564 scopus 로고    scopus 로고
    • FUJITA O., TATSUMI M., TANABAYASHI K., YAMADA A.: Development of a real-time PCR assay for detection and quantification of Francisella tularensis. Japan.J.Infect.Dis. 59, 46-51 (2006).
    • FUJITA O., TATSUMI M., TANABAYASHI K., YAMADA A.: Development of a real-time PCR assay for detection and quantification of Francisella tularensis. Japan.J.Infect.Dis. 59, 46-51 (2006).
  • 7
    • 20244370496 scopus 로고    scopus 로고
    • GRUNOW R., SPLETTSTOESSER W., MCD ONALD S., OTTERBEIN C., O'BRIEN T., MORGAN C., ALDRICH J., HOFER E., FINKE E.J., MEYER H.: Detection of Francisella tularensis in biological specimens using a capture enzyme-linked immunosorbent assay, an immunochromatographic hand-held assay, and a PCR. Clin.Diagn.Lab.Immunol. 7, 86-90 (2000).
    • GRUNOW R., SPLETTSTOESSER W., MCD ONALD S., OTTERBEIN C., O'BRIEN T., MORGAN C., ALDRICH J., HOFER E., FINKE E.J., MEYER H.: Detection of Francisella tularensis in biological specimens using a capture enzyme-linked immunosorbent assay, an immunochromatographic hand-held assay, and a PCR. Clin.Diagn.Lab.Immunol. 7, 86-90 (2000).
  • 9
    • 12744275027 scopus 로고    scopus 로고
    • The development of tools for diagnosis of tularemia and typing of Francisella tularensis
    • JOHANSSON A., FORSMAN M., SJOSTEDT A.: The development of tools for diagnosis of tularemia and typing of Francisella tularensis. APMIS 112, 898-907 (2004).
    • (2004) APMIS , vol.112 , pp. 898-907
    • JOHANSSON, A.1    FORSMAN, M.2    SJOSTEDT, A.3
  • 10
    • 1842853135 scopus 로고    scopus 로고
    • Identification of Francisella tularensis using real-time fluorescence polymerase chain reaction
    • MCAVIN J.C., MORTON M.M., ROUDABUSH R.M., ATCHLEY D.H., HICKMAN J.R.: Identification of Francisella tularensis using real-time fluorescence polymerase chain reaction. Mil.Med. 169, 330-333 (2004).
    • (2004) Mil.Med , vol.169 , pp. 330-333
    • MCAVIN, J.C.1    MORTON, M.M.2    ROUDABUSH, R.M.3    ATCHLEY, D.H.4    HICKMAN, J.R.5
  • 12
    • 0026832837 scopus 로고
    • Development of a piezoelectric immunosenzor for the detection of Enterobacteria
    • PLOMER M., GUILBAULT G.G., HOCK B.: Development of a piezoelectric immunosenzor for the detection of Enterobacteria. Enzyme Microb.Technol. 14, 230-235 (1992).
    • (1992) Enzyme Microb.Technol , vol.14 , pp. 230-235
    • PLOMER, M.1    GUILBAULT, G.G.2    HOCK, B.3
  • 13
    • 16344389544 scopus 로고    scopus 로고
    • Piezoelectric immunosensor for Francisella tularensis detection using immunoglobulin M in a limiting dilution
    • POHANKA M., SKLÁDAL P.: Piezoelectric immunosensor for Francisella tularensis detection using immunoglobulin M in a limiting dilution. Anal.Lett. 38, 411-422 (2005).
    • (2005) Anal.Lett , vol.38 , pp. 411-422
    • POHANKA, M.1    SKLÁDAL, P.2
  • 14
    • 0346725084 scopus 로고    scopus 로고
    • Target discrimination by surface-immobilized molecular beacons designed to detect Francisella tularensis
    • RAMACHANDRAN A., FLINCHBAUGH J., AYOUBI P., OLAH G.A., MALAYER J.R.: Target discrimination by surface-immobilized molecular beacons designed to detect Francisella tularensis. Biosens.Bioelectron. 19, 727-736 (2004).
    • (2004) Biosens.Bioelectron , vol.19 , pp. 727-736
    • RAMACHANDRAN, A.1    FLINCHBAUGH, J.2    AYOUBI, P.3    OLAH, G.A.4    MALAYER, J.R.5
  • 15
    • 0036266006 scopus 로고    scopus 로고
    • Exposure of laboratory workers to Francisella tularensis despite a bioterrorism procedure
    • SHAPIRO D.S., SCHWARTZ D.R.: Exposure of laboratory workers to Francisella tularensis despite a bioterrorism procedure. J.Clin. Microbiol. 40, 2278-2281 (2002).
    • (2002) J.Clin. Microbiol , vol.40 , pp. 2278-2281
    • SHAPIRO, D.S.1    SCHWARTZ, D.R.2
  • 16
    • 0141829166 scopus 로고    scopus 로고
    • Piezoelectric quartz crystal sensors applied for bioanalytical assays and characterization of affinity interactions
    • SKLÁDAL P.: Piezoelectric quartz crystal sensors applied for bioanalytical assays and characterization of affinity interactions. J.Brazil Chem.Soc. 14, 491-502 (2003).
    • (2003) J.Brazil Chem.Soc , vol.14 , pp. 491-502
    • SKLÁDAL, P.1
  • 17
    • 33144481854 scopus 로고    scopus 로고
    • Fiber-optic microsphere-based array for multiplexed biological warfare agent detection
    • SONG L.N., AHN A., WALT D.R.: Fiber-optic microsphere-based array for multiplexed biological warfare agent detection. Anal.Chem. 78, 1023-1033 (2006).
    • (2006) Anal.Chem , vol.78 , pp. 1023-1033
    • SONG, L.N.1    AHN, A.2    WALT, D.R.3
  • 18
    • 32944467067 scopus 로고    scopus 로고
    • Diagnosis procedures in tularemia with special focus on molecular and immunological techniques
    • SPLETTSTOESSER W.D., TOMASO H., AL DAHOUK S., NEUBAUER H., SCHUFF-WERNER P.: Diagnosis procedures in tularemia with special focus on molecular and immunological techniques. J.VetMed.Ser.B 52, 249-261 (2005).
    • (2005) J.VetMed.Ser.B , vol.52 , pp. 249-261
    • SPLETTSTOESSER, W.D.1    TOMASO, H.2    AL DAHOUK, S.3    NEUBAUER, H.4    SCHUFF-WERNER, P.5
  • 19
    • 33646865450 scopus 로고    scopus 로고
    • Francisella tularensis DNA aptamers detect tularemia antigen from different subspecies by aptamer-linked immobilized sorbent assay
    • VIVEKANANDA J., KIEL J.L.: Anti-Francisella tularensis DNA aptamers detect tularemia antigen from different subspecies by aptamer-linked immobilized sorbent assay. Lab.Invest. 86, 610-618 (2006).
    • (2006) Lab.Invest , vol.86 , pp. 610-618
    • VIVEKANANDA, J.1    KIEL, J.L.2    Anti-3
  • 20
    • 0345735943 scopus 로고    scopus 로고
    • Immunology of bacterial polysaccharide antigens
    • WEINTRAUB A.: Immunology of bacterial polysaccharide antigens. Carbohydr.Res. 338, 2539-2547 (2003).
    • (2003) Carbohydr.Res , vol.338 , pp. 2539-2547
    • WEINTRAUB, A.1
  • 21
    • 0036015962 scopus 로고    scopus 로고
    • Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance
    • WONG Y.Y., NG S.P., NG M.H., SI S.H., YAO S.Z., FUNG Y.S.: Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance. Biosens.Bioelectron. 17, 676-684 (2002).
    • (2002) Biosens.Bioelectron , vol.17 , pp. 676-684
    • WONG, Y.Y.1    NG, S.P.2    NG, M.H.3    SI, S.H.4    YAO, S.Z.5    FUNG, Y.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.