Volumn 14, Issue 2, 2007, Pages 87-95

Acute and chronic consequences of non-pulsatile blood flow pattern in long-term total artificial heart experiment

Author keywords

Artificial heart; Bulbar conjunctiva; Microcirculation; Perfusion; Pulsatility

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; ARTIFICIAL HEART; ARTIFICIAL HEART PACEMAKER; BLEEDING; BLOOD FLOW; BLOOD PUMP; CAPILLARY DENSITY; CONJUNCTIVA; CONTROLLED STUDY; EDEMA; ERYTHROCYTE; EXPERIMENTAL ANIMAL; FEMALE; GANGRENE; GOAT; HEART ASSIST DEVICE; HEART PERFUSION; HEART TRANSPLANTATION; HISTOPATHOLOGY; HYPOXIA; JAPAN; KIDNEY PARENCHYMA; LIVER; LUNG PARENCHYMA; MICROCIRCULATION; NONHUMAN; NUTRIENT SUPPLY; OXYGEN SUPPLY; PRIORITY JOURNAL; PULSATILE FLOW; PULSE PRESSURE; VASCULARIZATION; VENOUS STASIS;

EID: 35148873245     PISSN: 09284680     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.pathophys.2007.06.002     Document Type: Article
Times cited : (22)

References (31)
  • 1
    • 0023905313 scopus 로고
    • Microcirculation and artificial heart research
    • Lubbe A.S. Microcirculation and artificial heart research. Artif. Organs 12 (1988) 86-88
    • (1988) Artif. Organs , vol.12 , pp. 86-88
    • Lubbe, A.S.1
  • 2
    • 0034010554 scopus 로고    scopus 로고
    • Pulsatile flow enhances endothelium-derived nitric oxide release in the peripheral vasculature
    • Nakano T., Tominaga R., Nagano I., Okabe H., and Yasui H. Pulsatile flow enhances endothelium-derived nitric oxide release in the peripheral vasculature. Am. J. Physiol. Heart. Circ. Physiol. 278 (2000) 1098-1104
    • (2000) Am. J. Physiol. Heart. Circ. Physiol. , vol.278 , pp. 1098-1104
    • Nakano, T.1    Tominaga, R.2    Nagano, I.3    Okabe, H.4    Yasui, H.5
  • 3
    • 12244312565 scopus 로고
    • Factors influencing hemodynamics, blood chemical data, and hormone secretion of total artificial heart
    • Niimi H., Oda M., Sawada T., and Xiu R.J. (Eds), Elsevier Pergamon, Oxford
    • Imachi K., Abe Y., Chinzei T., Mabuchi K., Imanishi K., Isoyama T., Kouno A., Ono T., and Fujimasa I. Factors influencing hemodynamics, blood chemical data, and hormone secretion of total artificial heart. In: Niimi H., Oda M., Sawada T., and Xiu R.J. (Eds). Progress in Microcirculation Research (1994), Elsevier Pergamon, Oxford 453-458
    • (1994) Progress in Microcirculation Research , pp. 453-458
    • Imachi, K.1    Abe, Y.2    Chinzei, T.3    Mabuchi, K.4    Imanishi, K.5    Isoyama, T.6    Kouno, A.7    Ono, T.8    Fujimasa, I.9
  • 5
    • 12244282488 scopus 로고
    • Disturbances in the regulatory mechanisms of macro and microcirculation during total artificial heart
    • Niimi H., Oda M., Sawada T., and Xiu R.J. (Eds), Elsevier Pergamon, Oxford
    • Vasku J. Disturbances in the regulatory mechanisms of macro and microcirculation during total artificial heart. In: Niimi H., Oda M., Sawada T., and Xiu R.J. (Eds). Progress in Microcirculation Research (1994), Elsevier Pergamon, Oxford 447-451
    • (1994) Progress in Microcirculation Research , pp. 447-451
    • Vasku, J.1
  • 7
    • 3142688417 scopus 로고    scopus 로고
    • Microcirculation of the bulbar conjunctiva in the goat implanted with a total artificial heart: effects of pulsatile and nonpulsatile flow
    • Baba A., Dobsak P., Saito I., Isoyama T., Takiura K., Abe Y., Chinzei T., Vasku J., and Imachi K. Microcirculation of the bulbar conjunctiva in the goat implanted with a total artificial heart: effects of pulsatile and nonpulsatile flow. ASAIO J. 50 (2004) 21-27
    • (2004) ASAIO J. , vol.50 , pp. 21-27
    • Baba, A.1    Dobsak, P.2    Saito, I.3    Isoyama, T.4    Takiura, K.5    Abe, Y.6    Chinzei, T.7    Vasku, J.8    Imachi, K.9
  • 8
    • 0028604410 scopus 로고
    • Evaluation of pulsatile and non-pulsatile flow in capillaries of goat skeletal muscle using intravital microscopy
    • Lee J.J., Tyml K., Menkis A.H., Novick R.J., and Mckenzie F.N. Evaluation of pulsatile and non-pulsatile flow in capillaries of goat skeletal muscle using intravital microscopy. Microvasc. Res. 48 (1994) 316-327
    • (1994) Microvasc. Res. , vol.48 , pp. 316-327
    • Lee, J.J.1    Tyml, K.2    Menkis, A.H.3    Novick, R.J.4    Mckenzie, F.N.5
  • 9
    • 0242376601 scopus 로고
    • Future trends on microcirculatory research
    • Kaley G., and Altura B.M. (Eds), University Park Press, Baltimore
    • Wayland H., and Johnson P.C. Future trends on microcirculatory research. In: Kaley G., and Altura B.M. (Eds). Microcirculation vol. 3 (1980), University Park Press, Baltimore 492-496
    • (1980) Microcirculation , vol.3 , pp. 492-496
    • Wayland, H.1    Johnson, P.C.2
  • 10
    • 0030560882 scopus 로고    scopus 로고
    • Microcirculation of a bulbar conjunctiva in calves with the total artificial heart: results of a long-term study
    • Dobsak P., Dostal M., Sehnalova O., Vasku J., and Kuchtickova S. Microcirculation of a bulbar conjunctiva in calves with the total artificial heart: results of a long-term study. Pathophysiology 3 (1996) 213-217
    • (1996) Pathophysiology , vol.3 , pp. 213-217
    • Dobsak, P.1    Dostal, M.2    Sehnalova, O.3    Vasku, J.4    Kuchtickova, S.5
  • 13
    • 33744731087 scopus 로고    scopus 로고
    • Influence of flow design on microcirculation in conditions of undulation pump-left ventricle assist device testing
    • Dobsak P., Novakova M., Baba A., Vasku J., Isoyama T., Saito I., Abe Y., Chinzei T., and Imachi K. Influence of flow design on microcirculation in conditions of undulation pump-left ventricle assist device testing. Artif. Organs 30 (2006) 478-487
    • (2006) Artif. Organs , vol.30 , pp. 478-487
    • Dobsak, P.1    Novakova, M.2    Baba, A.3    Vasku, J.4    Isoyama, T.5    Saito, I.6    Abe, Y.7    Chinzei, T.8    Imachi, K.9
  • 14
    • 10044252036 scopus 로고    scopus 로고
    • Impact of pulsatile flow on microcirculation
    • Undar A., Rosenberg G., and Myers J.L. Impact of pulsatile flow on microcirculation. ASAIO J. 50 (2004) 624-625
    • (2004) ASAIO J. , vol.50 , pp. 624-625
    • Undar, A.1    Rosenberg, G.2    Myers, J.L.3
  • 16
    • 26444564727 scopus 로고    scopus 로고
    • Precise quantification of pulsatility is a necessity for direct comparisons of six different pediatric heart-lung machines in a neonatal CPB model
    • Undar A., Eichstaedt H.C., Masai T., Bigley J.E., and Kunselman A.R. Precise quantification of pulsatility is a necessity for direct comparisons of six different pediatric heart-lung machines in a neonatal CPB model. ASAIO J. 51 (2005) 600-603
    • (2005) ASAIO J. , vol.51 , pp. 600-603
    • Undar, A.1    Eichstaedt, H.C.2    Masai, T.3    Bigley, J.E.4    Kunselman, A.R.5
  • 17
    • 3142723486 scopus 로고    scopus 로고
    • How should investigators compare different perfusion modes or different types of pulsatile flow during chronic support?
    • Undar A., Rosenberg G., and Myers J.L. How should investigators compare different perfusion modes or different types of pulsatile flow during chronic support?. ASAIO J. 50 (2004) 401-402
    • (2004) ASAIO J. , vol.50 , pp. 401-402
    • Undar, A.1    Rosenberg, G.2    Myers, J.L.3
  • 18
    • 2542419343 scopus 로고    scopus 로고
    • Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support
    • Undar A. Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support. Artif. Organs 28 (2004) 439-443
    • (2004) Artif. Organs , vol.28 , pp. 439-443
    • Undar, A.1
  • 20
    • 0025139807 scopus 로고
    • Effects of pulsatile perfusion on plasma catecholamine levels and hemodynamics during and after cardiac operations with cardiopulmonary bypass
    • Minami K., Korner M.M., Vyska K., Kleesiek K., Knobl H., and Korfer R. Effects of pulsatile perfusion on plasma catecholamine levels and hemodynamics during and after cardiac operations with cardiopulmonary bypass. J. Thorac. Cardiovasc. Surg. 99 (1990) 82-91
    • (1990) J. Thorac. Cardiovasc. Surg. , vol.99 , pp. 82-91
    • Minami, K.1    Korner, M.M.2    Vyska, K.3    Kleesiek, K.4    Knobl, H.5    Korfer, R.6
  • 21
    • 0030036571 scopus 로고    scopus 로고
    • Can we develop a non-pulsatile permanent rotary blood pump? Yes, we can
    • Nose Y., Kawahito K., and Nakazawa T. Can we develop a non-pulsatile permanent rotary blood pump? Yes, we can. Artif. Organs 20 (1996) 467-474
    • (1996) Artif. Organs , vol.20 , pp. 467-474
    • Nose, Y.1    Kawahito, K.2    Nakazawa, T.3
  • 22
    • 0036389474 scopus 로고    scopus 로고
    • Comparison of pulsatile and non-pulsatile perfusion of the lung in an extracorporeal large animal model
    • Brandes H., Albes J.M., Conzelmann A., Wehrmann M., and Ziemer G. Comparison of pulsatile and non-pulsatile perfusion of the lung in an extracorporeal large animal model. Eur. Surg. Res. 34 (2002) 321-329
    • (2002) Eur. Surg. Res. , vol.34 , pp. 321-329
    • Brandes, H.1    Albes, J.M.2    Conzelmann, A.3    Wehrmann, M.4    Ziemer, G.5
  • 23
    • 0017118309 scopus 로고
    • Effect of pulsatile and non-pulsatile flow during cardiopulmonary bypass on left ventricular ejection fraction early after aorto-coronary bypass surgery
    • Maddoux G., Pappas G., Jenkins M., Battock D., Trow R., Smith Jr. S.C., and Steele P. Effect of pulsatile and non-pulsatile flow during cardiopulmonary bypass on left ventricular ejection fraction early after aorto-coronary bypass surgery. Am. J. Cardiol. 37 (1976) 1000-1006
    • (1976) Am. J. Cardiol. , vol.37 , pp. 1000-1006
    • Maddoux, G.1    Pappas, G.2    Jenkins, M.3    Battock, D.4    Trow, R.5    Smith Jr., S.C.6    Steele, P.7
  • 24
    • 0021023824 scopus 로고
    • Pulsatile and non-pulsatile cardiopulmonary bypass: review of a counterproductive controversy
    • Hickey P.R., Buckley M.J., and Philbin D.M. Pulsatile and non-pulsatile cardiopulmonary bypass: review of a counterproductive controversy. Ann. Thorac. Surg. 36 (1983) 720-737
    • (1983) Ann. Thorac. Surg. , vol.36 , pp. 720-737
    • Hickey, P.R.1    Buckley, M.J.2    Philbin, D.M.3
  • 25
    • 0030020565 scopus 로고    scopus 로고
    • The effects of pulsatile and nonpulsatile systemic perfusion on renal sympathetic nerve activity in anesthetized dogs
    • Fukae K., Tominaga R., Tokunaga S., Kawachi Y., Imaizumi T., and Yasui H. The effects of pulsatile and nonpulsatile systemic perfusion on renal sympathetic nerve activity in anesthetized dogs. J. Thorac. Cardiovasc. Surg. 111 (1996) 478-484
    • (1996) J. Thorac. Cardiovasc. Surg. , vol.111 , pp. 478-484
    • Fukae, K.1    Tominaga, R.2    Tokunaga, S.3    Kawachi, Y.4    Imaizumi, T.5    Yasui, H.6
  • 27
    • 0015495957 scopus 로고
    • Pulsatile blood flow
    • Milnor W.R. Pulsatile blood flow. N. Engl. J. Med. 287 (1972) 27-34
    • (1972) N. Engl. J. Med. , vol.287 , pp. 27-34
    • Milnor, W.R.1
  • 28
    • 23144461841 scopus 로고    scopus 로고
    • The effects of pulsatile versus non-pulsatile extracorporeal circulation on the pattern of coronary artery blood flow during cardiac arrest
    • Son H.S., Sun K., Fang Y.H., Park S.Y., Hwang C.M., Park S.M., Lee S.H., Kim K.T., and Lee I.S. The effects of pulsatile versus non-pulsatile extracorporeal circulation on the pattern of coronary artery blood flow during cardiac arrest. Int. J. Artif. Organs 28 (2005) 609-616
    • (2005) Int. J. Artif. Organs , vol.28 , pp. 609-616
    • Son, H.S.1    Sun, K.2    Fang, Y.H.3    Park, S.Y.4    Hwang, C.M.5    Park, S.M.6    Lee, S.H.7    Kim, K.T.8    Lee, I.S.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.