How should investigators compare different perfusion modes or different types of pulsatile flow during chronic support?

Author keywords

[No Author keywords available]

Indexed keywords

ARTERIAL PRESSURE; BLOOD PUMP; CAPILLARY FLOW; ENERGY TRANSFER; FLOW RATE; HEART FAILURE; HEMODYNAMICS; INTERMETHOD COMPARISON; LETTER; LONG TERM CARE; PERFUSION; PRESSURE VOLUME CURVE; PULSATILE FLOW;

EID: 3142723486     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002480-200407000-00023     Document Type: Letter
Times cited : (4)

References (14)
  • 1
    • 0346059626 scopus 로고    scopus 로고
    • Hemodynamic and pressure-volume responses to continuous and pulsatile ventricular assist in an adult mock circulation
    • Koenig SC, Pantalos GM, Gillars KJ, Ewert DL, Litwak KN, Etoch SW: Hemodynamic and pressure-volume responses to continuous and pulsatile ventricular assist in an adult mock circulation. ASAIO J 50: 15-24, 2004.
    • (2004) ASAIO J , vol.50 , pp. 15-24
    • Koenig, S.C.1    Pantalos, G.M.2    Gillars, K.J.3    Ewert, D.L.4    Litwak, K.N.5    Etoch, S.W.6
  • 2
    • 2542419343 scopus 로고    scopus 로고
    • Myths and truths of pulsatile and non-pulsatile perfusion during acute and chronic cardiac support
    • Ündar A: Myths and truths of pulsatile and non-pulsatile perfusion during acute and chronic cardiac support (Editorial). Artif Organs 28: 439-443, 2004.
    • (2004) Artif Organs , vol.28 , pp. 439-443
    • Ündar, A.1
  • 3
    • 0036964893 scopus 로고    scopus 로고
    • The ABCs of research on pulsatile versus nonpulsatile perfusion during cardiopulmonary bypass
    • Ündar A: The ABCs of research on pulsatile versus nonpulsatile perfusion during cardiopulmonary bypass (Editorial). Med Sci Monit 8: ED21-ED24, 2002.
    • (2002) Med Sci Monit , vol.8
    • Ündar, A.1
  • 4
    • 0028027768 scopus 로고
    • Hemodynamic analysis could resolve the pulsatile blood flow controversy
    • Wright G: Hemodynamic analysis could resolve the pulsatile blood flow controversy. Ann Thorac Surg 58: 1199-1204, 1994.
    • (1994) Ann Thorac Surg , vol.58 , pp. 1199-1204
    • Wright, G.1
  • 5
    • 0037240078 scopus 로고    scopus 로고
    • Fundamentals of pulsatile versus nonpulsatile flow during chronic support
    • Ündar A: Fundamentals of pulsatile versus nonpulsatile flow during chronic support (Letter). ASAIO J 49: 139-140, 2003.
    • (2003) ASAIO J , vol.49 , pp. 139-140
    • Ündar, A.1
  • 6
    • 0242552124 scopus 로고    scopus 로고
    • Energy equivalent pressure formula is for precise quantification of different perfusion modes
    • Ündar A: Energy equivalent pressure formula is for precise quantification of different perfusion modes (Letter). Ann Thorac Surg 76: 1777-1778, 2003.
    • (2003) Ann Thorac Surg , vol.76 , pp. 1777-1778
    • Ündar, A.1
  • 7
    • 0037785164 scopus 로고    scopus 로고
    • Quantification of arterial pressure and pump flow waveforms for pulsatile and continuous flow devices during chronic support
    • Ündar A, Fraser CD: Quantification of arterial pressure and pump flow waveforms for pulsatile and continuous flow devices during chronic support (Letter). J Heart Lung Transplant 22: 706-707, 2003.
    • (2003) J Heart Lung Transplant , vol.22 , pp. 706-707
    • Ündar, A.1    Fraser, C.D.2
  • 9
    • 24444455774 scopus 로고    scopus 로고
    • Precise quantification of pressure-flow waveforms of a pulsatile VAD during chronic support
    • Ündar A, Zapanta C, Reibson J, et al: Precise quantification of pressure-flow waveforms of a pulsatile VAD during chronic support (Abstract), ASAIO J 50: 159, 2004.
    • (2004) ASAIO J , vol.50 , pp. 159
    • Ündar, A.1    Zapanta, C.2    Reibson, J.3
  • 10
    • 1642564239 scopus 로고    scopus 로고
    • Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support
    • Klotz S, Deng MC, Stypmann J, et al: Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support. Ann Thorac Surg 77: 143-150, 2004.
    • (2004) Ann Thorac Surg , vol.77 , pp. 143-150
    • Klotz, S.1    Deng, M.C.2    Stypmann, J.3
  • 11
    • 10744220932 scopus 로고    scopus 로고
    • Evaluation of pulsatile and nonpulsatile flow in microvessels of the bulbar conjunctiva in the goat with an undulation pump artificial heart
    • Baba A, Dobsak P, Mochizuki S, et al: Evaluation of pulsatile and nonpulsatile flow in microvessels of the bulbar conjunctiva in the goat with an undulation pump artificial heart. Artif Organs 27: 875-881, 2003.
    • (2003) Artif Organs , vol.27 , pp. 875-881
    • Baba, A.1    Dobsak, P.2    Mochizuki, S.3
  • 12
    • 10244260395 scopus 로고    scopus 로고
    • The role of pulsatility in end-organ microcirculation after cardiogenic shock
    • Orime Y, Shiono M, Nakata K, et al: The role of pulsatility in end-organ microcirculation after cardiogenic shock. ASAIO J 42: M724-729, 1996.
    • (1996) ASAIO J , vol.42
    • Orime, Y.1    Shiono, M.2    Nakata, K.3
  • 13
    • 0036046244 scopus 로고    scopus 로고
    • The alphabet of research on pulsatile and nonpulsatile (continuous flow) perfusion during chronic support
    • Ündar A, Fraser CD: The alphabet of research on pulsatile and nonpulsatile (continuous flow) perfusion during chronic support (Letter). Artif Organs 26: 812-813, 2002.
    • (2002) Artif Organs , vol.26 , pp. 812-813
    • Ündar, A.1    Fraser, C.D.2
  • 14
    • 0033978111 scopus 로고    scopus 로고
    • Physiology of non-pulsatile circulation: Acute versus chronic support
    • Ündar A, Fraser CD: Physiology of non-pulsatile circulation: Acute versus chronic support (Letter). ASAIO J 46: 150, 2000.
    • (2000) ASAIO J , vol.46 , pp. 150
    • Ündar, A.1    Fraser, C.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.