-
1
-
-
4444270625
-
Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers
-
Aubry J F, Beaulieu L, Girouard L M, Aubin S, Tremblay D, Laverdi J and Vigneault E 2004 Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers Int. J. Radiat. Oncol. Biol. Phys. 60 30-9
-
(2004)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.60
, Issue.1
, pp. 30-39
-
-
Aubry, J.F.1
Beaulieu, L.2
Girouard, L.M.3
Aubin, S.4
Tremblay, D.5
Laverdi, J.6
Vigneault, E.7
-
2
-
-
0033955778
-
Real-time three-dimensional motion analysis for patient positioning verification
-
Baroni G, Ferrigno G, Orecchia R and Pedotti A 2000 Real-time three-dimensional motion analysis for patient positioning verification Radiother. Oncol. 54 21-7
-
(2000)
Radiother. Oncol.
, vol.54
, Issue.1
, pp. 21-27
-
-
Baroni, G.1
Ferrigno, G.2
Orecchia, R.3
Pedotti, A.4
-
3
-
-
30544455389
-
3D optoelectronic analysis of interfractional patient setup variability in frameless extracranial stereotactic radiotherapy
-
Baroni G, Garibaldi C, Riboldi M, Spadea M F, Catalano G, Tagaste B, Tosi G, Orecchia R and Pedotti A 2006 3D optoelectronic analysis of interfractional patient setup variability in frameless extracranial stereotactic radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 64 635-42
-
(2006)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.64
, Issue.2
, pp. 635-642
-
-
Baroni, G.1
Garibaldi, C.2
Riboldi, M.3
Spadea, M.F.4
Catalano, G.5
Tagaste, B.6
Tosi, G.7
Orecchia, R.8
Pedotti, A.9
-
4
-
-
2942531270
-
Dosimetric effects within target and organs at risk of interfractional patient mispositioning in left breast cancer radiotherapy
-
Baroni G, Garibaldi C, Scabini M, Riboldi M, Catalano G, Tosi G, Orecchia R and Pedotti A 2004 Dosimetric effects within target and organs at risk of interfractional patient mispositioning in left breast cancer radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 59 861-71
-
(2004)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.59
, Issue.3
, pp. 861-871
-
-
Baroni, G.1
Garibaldi, C.2
Scabini, M.3
Riboldi, M.4
Catalano, G.5
Tosi, G.6
Orecchia, R.7
Pedotti, A.8
-
7
-
-
33749046687
-
Image-guided radiotherapy: Rationale, benefits, and limitations
-
Dawson L A and Sharpe M B 2006 Image-guided radiotherapy: rationale, benefits, and limitations Lancet Oncol. 7 848-58
-
(2006)
Lancet Oncol.
, vol.7
, Issue.10
, pp. 848-858
-
-
Dawson, L.A.1
Sharpe, M.B.2
-
8
-
-
24044543599
-
Real-time intra-fraction-motion tracking using the treatment couch: A feasibility study
-
D'Souza W D, Naqvi S A and Yu C X 2005 Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study Phys. Med. Biol. 50 4021-33
-
(2005)
Phys. Med. Biol.
, vol.50
, Issue.17
, pp. 4021-4033
-
-
D'Souza, W.D.1
Naqvi, S.A.2
Yu, C.X.3
-
9
-
-
0035437717
-
The distribution of target registration error in rigid-body point-based registration
-
Fitzpatrick J M and West J B 2001 The distribution of target registration error in rigid-body point-based registration IEEE Trans. Med. Imaging 20 917-27
-
(2001)
IEEE Trans. Med. Imaging
, vol.20
, Issue.9
, pp. 917-927
-
-
Fitzpatrick, J.M.1
West, J.B.2
-
11
-
-
33645981277
-
A neural network based method for optical patient set-up registration in breast radiotherapy
-
Frosio I, Spadea M F, De Momi E, Riboldi M, Baroni G, Ferrigno G, Orecchia R and Pedotti A 2006 A neural network based method for optical patient set-up registration in breast radiotherapy Ann. Biomed. Eng. 34 677-86
-
(2006)
Ann. Biomed. Eng.
, vol.34
, Issue.4
, pp. 677-686
-
-
Frosio, I.1
Spadea, M.F.2
De Momi, E.3
Riboldi, M.4
Baroni, G.5
Ferrigno, G.6
Orecchia, R.7
Pedotti, A.8
-
12
-
-
34748859687
-
Adaptive radiotherapy in prostate conformal dynamic treatment
-
Garibaldi C, Cattani F, Castiglioni S, Tagaste B, Riboldi M, Cambria R, Fossati P, Tosi G and Orecchia R 2005 Adaptive radiotherapy in prostate conformal dynamic treatment Radiother. Oncol. 76 (Suppl. 2) S73
-
(2005)
Radiother. Oncol.
, vol.76
, Issue.SUPPL. 2
, pp. 73
-
-
Garibaldi, C.1
Cattani, F.2
Castiglioni, S.3
Tagaste, B.4
Riboldi, M.5
Cambria, R.6
Fossati, P.7
Tosi, G.8
Orecchia, R.9
-
13
-
-
0022865373
-
Future paths for integer programming and links to artificial intelligence
-
Glover F 1986 Future paths for integer programming and links to artificial intelligence Comput. Oper. Res. 13 533-49
-
(1986)
Comput. Oper. Res.
, vol.13
, Issue.5
, pp. 533-549
-
-
Glover, F.1
-
16
-
-
34250293137
-
A globally convergent method for nonlinear programming
-
Han S P 1977 A globally convergent method for nonlinear programming J. Optim. Theory Appl. 22 97
-
(1977)
J. Optim. Theory Appl.
, vol.22
, Issue.3
, pp. 297
-
-
Han, S.P.1
-
17
-
-
0033955779
-
The dosimetric consequences of inter-fractional patient movement on conventional and intensity modulated breast radiotherapy treatments
-
Hector C L, Evans P M and Webb S 2000 The dosimetric consequences of inter-fractional patient movement on conventional and intensity modulated breast radiotherapy treatments Radiother. Oncol. 54 57-64
-
(2000)
Radiother. Oncol.
, vol.54
, Issue.1
, pp. 57-64
-
-
Hector, C.L.1
Evans, P.M.2
Webb, S.3
-
18
-
-
0035370844
-
The dosimetric consequences of inter-fractional patient movement on three classes of intensity-modulated delivery techniques in breast radiotherapy
-
Hector C L, Evans P M and Webb S 2001 The dosimetric consequences of inter-fractional patient movement on three classes of intensity-modulated delivery techniques in breast radiotherapy Radiother. Oncol. 59 281-91
-
(2001)
Radiother. Oncol.
, vol.59
, Issue.3
, pp. 281-291
-
-
Hector, C.L.1
Evans, P.M.2
Webb, S.3
-
20
-
-
0032885355
-
Automated docking of peptides and proteins by using a genetic algorithm combined with a tabu search
-
Hou T, Wang J, Chen L and Xu X 1999 Automated docking of peptides and proteins by using a genetic algorithm combined with a tabu search Protein Eng. 12 639-47
-
(1999)
Protein Eng.
, vol.12
, Issue.8
, pp. 639-647
-
-
Hou, T.1
Wang, J.2
Chen, L.3
Xu, X.4
-
21
-
-
33646263112
-
The clinical implementation of respiratory-gated intensity-modulated radiotherapy
-
Keall P, Vedam S, George R, Bartee C, Siebers J, Lerma F, Weiss E and Chung T 2006 The clinical implementation of respiratory-gated intensity-modulated radiotherapy Med. Dosim. 31 152-62
-
(2006)
Med. Dosim.
, vol.31
, Issue.2
, pp. 152-162
-
-
Keall, P.1
Vedam, S.2
George, R.3
Bartee, C.4
Siebers, J.5
Lerma, F.6
Weiss, E.7
Chung, T.8
-
23
-
-
0032527644
-
Daily CT localization for correcting portal errors in the treatment of prostate cancer
-
Lattanzi J, McNeely S, Hanlon A, Das I, Schultheiss T E and Hanks G E 1998 Daily CT localization for correcting portal errors in the treatment of prostate cancer Int. J. Radiat. Oncol. Biol. Phys. 41 1079-86
-
(1998)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.41
, Issue.5
, pp. 1079-1086
-
-
Lattanzi, J.1
McNeely, S.2
Hanlon, A.3
Das, I.4
Schultheiss, T.E.5
Hanks, G.E.6
-
24
-
-
0037321855
-
Optimal marker placement in photogrammetry patient positioning system
-
Liu H, Yu Y, Schell M C, O'Dell W G, Ruo R and Okunieff P 2003 Optimal marker placement in photogrammetry patient positioning system Med. Phys. 30 103-10
-
(2003)
Med. Phys.
, vol.30
, Issue.2
, pp. 103-110
-
-
Liu, H.1
Yu, Y.2
Schell, M.C.3
O'Dell, W.G.4
Ruo, R.5
Okunieff, P.6
-
25
-
-
0842306297
-
Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment
-
Mageras G S and Yorke E 2004 Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment Semin. Radiat. Oncol. 14 65-75
-
(2004)
Semin. Radiat. Oncol.
, vol.14
, Issue.1
, pp. 65-75
-
-
Mageras, G.S.1
Yorke, E.2
-
26
-
-
0032593076
-
Integrating genetic algorithms, tabu search, and simulated annealing for the unit commitment problem
-
Mantawy A H, Abdel-Magid Y L and Selim S Z 1999 Integrating genetic algorithms, tabu search, and simulated annealing for the unit commitment problem IEEE Trans. Power Syst. 14 829-35
-
(1999)
IEEE Trans. Power Syst.
, vol.14
, Issue.3
, pp. 829-835
-
-
Mantawy, A.H.1
Abdel-Magid, Y.L.2
Selim, S.Z.3
-
27
-
-
0035424531
-
Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer
-
Martinez A A, Yan D, Lockman D, Brabbins D, Kota K, Sharpe M, Jaffray D A, Vicini F and Wong J 2001 Improvement in dose escalation using the process of adaptive radiotherapy combined with three-dimensional conformal or intensity-modulated beams for prostate cancer Int. J. Radiat. Oncol. Biol. Phys. 50 1226-34
-
(2001)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.50
, Issue.5
, pp. 1226-1234
-
-
Martinez, A.A.1
Yan, D.2
Lockman, D.3
Brabbins, D.4
Kota, K.5
Sharpe, M.6
Jaffray, D.A.7
Vicini, F.8
Wong, J.9
-
28
-
-
0030405294
-
Registration of 3-D images using weighted geometrical features
-
Maurer C R Jr, Aboutanos G B, Dawant B M, Maciunas R J and Fitzpatrick J M 2000 Registration of 3-D images using weighted geometrical features IEEE Trans. Med. Imag. 15 836-49
-
(2000)
IEEE Trans. Med. Imag.
, vol.15
, Issue.6
, pp. 836-849
-
-
Maurer, C.R.1
Aboutanos, G.B.2
Dawant, B.M.3
MacIunas, R.J.4
Fitzpatrick, J.M.5
-
29
-
-
0032173364
-
Registration of head CT images to physical space using a weighted combination of points and surfaces
-
Maurer C R Jr, Maciunas R J and Fitzpatrick J M 1998 Registration of head CT images to physical space using a weighted combination of points and surfaces IEEE Trans. Med. Imag. 17 753-61
-
(1998)
IEEE Trans. Med. Imag.
, vol.17
, Issue.5
, pp. 753-761
-
-
Maurer, C.R.1
MacIunas, R.J.2
Fitzpatrick, J.M.3
-
30
-
-
20644446492
-
Optically guided patient positioning techniques
-
Meeks S L, Tome W A, Willoughby T R, Kupelian P A, Wagner T H, Buatti J M and Bova F J 2005 Optically guided patient positioning techniques Semin. Radiat. Oncol. 15 192-201
-
(2005)
Semin. Radiat. Oncol.
, vol.15
, Issue.3
, pp. 192-201
-
-
Meeks, S.L.1
Tome, W.A.2
Willoughby, T.R.3
Kupelian, P.A.4
Wagner, T.H.5
Buatti, J.M.6
Bova, F.J.7
-
31
-
-
0037377425
-
Nonlinear optimization and parallel computing
-
Migdalas A, Toraldo G and Kumar V 2003 Nonlinear optimization and parallel computing Parallel Comput. 29 375-91
-
(2003)
Parallel Comput.
, vol.29
, Issue.4
, pp. 375-391
-
-
Migdalas, A.1
Toraldo, G.2
Kumar, V.3
-
33
-
-
0035365076
-
A modified version of the K-means algorithm with a distance based on cluster symmetry
-
Mu-Chun S and Chien-Hsing C 2001 A modified version of the K-means algorithm with a distance based on cluster symmetry IEEE Trans. Pattern Anal. Mach. Intell. 23 674-80
-
(2001)
IEEE Trans. Pattern Anal. Mach. Intell.
, vol.23
, Issue.6
, pp. 674-680
-
-
Mu-Chun, S.1
Chien-Hsing, C.2
-
34
-
-
33947514462
-
An adaptive off-line procedure for radiotherapy of prostate cancer
-
Nuver T T, Hoogeman M S, Remeijer P, van Herk M and Lebesque J V 2007 An adaptive off-line procedure for radiotherapy of prostate cancer Int. J. Radiat. Oncol. Biol. Phys. 67 1559-67
-
(2007)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.67
, Issue.5
, pp. 1559-1567
-
-
Nuver, T.T.1
Hoogeman, M.S.2
Remeijer, P.3
Van Herk, M.4
Lebesque, J.V.5
-
35
-
-
0026463748
-
Brain parenchyma motion: Measurement with cine echoplanar MR imaging
-
Poncelet B P, Wedeen V J, Weisskoff R M and Cohen M S 1992 Brain parenchyma motion: measurement with cine echoplanar MR imaging Radiology 185 645-51
-
(1992)
Radiology
, vol.185
, Issue.3
, pp. 645-651
-
-
Poncelet, B.P.1
Wedeen, V.J.2
Weisskoff, R.M.3
Cohen, M.S.4
-
36
-
-
33645507949
-
Robust frameless stereotactic localization in extra-cranial radiotherapy
-
Riboldi M, Baroni G, Spadea M F, Bassanini F, Tagaste B, Garibaldi C, Orecchia R and Pedotti A 2006a Robust frameless stereotactic localization in extra-cranial radiotherapy Med. Phys. 33 1141-52
-
(2006)
Med. Phys.
, vol.33
, Issue.4
, pp. 1141-1152
-
-
Riboldi, M.1
Baroni, G.2
Spadea, M.F.3
Bassanini, F.4
Tagaste, B.5
Garibaldi, C.6
Orecchia, R.7
Pedotti, A.8
-
37
-
-
34748853657
-
Genetic evolutionary taboo search: A novel approach for optimal marker placement in infrared patient positioning
-
Riboldi M, Spadea M F, Tagaste B, Baroni G, Garibaldi C, Orecchia R and Pedotti A 2006b Genetic evolutionary taboo search: a novel approach for optimal marker placement in infrared patient positioning Med. Phys. 33 2161
-
(2006)
Med. Phys.
, vol.33
, Issue.6
, pp. 2161
-
-
Riboldi, M.1
Spadea, M.F.2
Tagaste, B.3
Baroni, G.4
Garibaldi, C.5
Orecchia, R.6
Pedotti, A.7
-
38
-
-
21044432866
-
A genetic algorithm for searching spatial configurations
-
Rodriguez M A and Jarur M C 2005 A genetic algorithm for searching spatial configurations IEEE Trans. Evol. Comput. 9 252-70
-
(2005)
IEEE Trans. Evol. Comput.
, vol.9
, Issue.3
, pp. 252-270
-
-
Rodriguez, M.A.1
Jarur, M.C.2
-
39
-
-
0032965071
-
Accuracy of a photogrammetry-based patient positioning and monitoring system for radiation therapy
-
Rogus R D, Stern R L and Kubo H D 1999 Accuracy of a photogrammetry-based patient positioning and monitoring system for radiation therapy Med. Phys. 26 721-28
-
(1999)
Med. Phys.
, vol.26
, Issue.5
, pp. 721-728
-
-
Rogus, R.D.1
Stern, R.L.2
Kubo, H.D.3
-
40
-
-
0014534297
-
A new approach to clustering
-
Ruspini E 1969 A new approach to clustering Inf. Control 15 22-32
-
(1969)
Inf. Control
, vol.15
, Issue.1
, pp. 22-32
-
-
Ruspini, E.1
-
41
-
-
0842284569
-
Intrafractional tumor motion: Lung and liver
-
Shirato H, Seppenwoolde Y, Kitamura K, Onimura R and Shimizu S 2004 Intrafractional tumor motion: lung and liver Semin. Radiat. Oncol. 14 10-8
-
(2004)
Semin. Radiat. Oncol.
, vol.14
, Issue.1
, pp. 10-18
-
-
Shirato, H.1
Seppenwoolde, Y.2
Kitamura, K.3
Onimura, R.4
Shimizu, S.5
-
42
-
-
0036834636
-
Clinical use of stereoscopic x-ray positioning of patients treated with conformal radiotherapy for prostate cancer
-
Soete G, Verellen D, Michielsen D, Vinh-Hung V, Van de Steene J, Van de Berge V, De Roover P, Keuppens K and Storme G 2002 Clinical use of stereoscopic x-ray positioning of patients treated with conformal radiotherapy for prostate cancer Int. J. Radiat. Oncol. Biol. Phys. 54 948-52
-
(2002)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.54
, Issue.3
, pp. 948-952
-
-
Soete, G.1
Verellen, D.2
Michielsen, D.3
Vinh-Hung, V.4
Van De Steene, J.5
Van De Berge, V.6
De Roover, P.7
Keuppens, K.8
Storme, G.9
-
43
-
-
0842306308
-
Errors and margins in radiotherapy
-
van Herk M 2004 Errors and margins in radiotherapy Semin. Radiat. Oncol. 14 52-64
-
(2004)
Semin. Radiat. Oncol.
, vol.14
, Issue.1
, pp. 52-64
-
-
Van Herk, M.1
-
44
-
-
0028803534
-
Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
-
van Herk M, Bruce A, Kroes G, Shouman T, Touw A and Lebesque J V 1995 Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration Int. J. Radiat. Oncol. Biol. Phys. 33 1311-20
-
(1995)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.33
, Issue.5
, pp. 1311-1320
-
-
Van Herk, M.1
Bruce, A.2
Kroes, G.3
Shouman, T.4
Touw, A.5
Lebesque, J.V.6
-
45
-
-
26944493434
-
Phase II dose escalation study of image-guided adaptive radiotherapy for prostate cancer: Use of dose-volume constraints to achieve rectal isotoxicity
-
Vargas C, Yan D, Kestin L L, Krauss D, Lockman D M, Brabbins D S and Martinez A A 2005 Phase II dose escalation study of image-guided adaptive radiotherapy for prostate cancer: use of dose-volume constraints to achieve rectal isotoxicity Int. J. Radiat. Oncol. Biol. Phys. 63 141-9
-
(2005)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.63
, Issue.1
, pp. 141-149
-
-
Vargas, C.1
Yan, D.2
Kestin, L.L.3
Krauss, D.4
Lockman, D.M.5
Brabbins, D.S.6
Martinez, A.A.7
-
46
-
-
0035156119
-
Infrared patient positioning for stereotactic radiosurgery of extracranial tumors
-
Wang L T, Solberg T D, Medin P M and Boone R 2001 Infrared patient positioning for stereotactic radiosurgery of extracranial tumors Comput. Biol. Med. 31 101-11
-
(2001)
Comput. Biol. Med.
, vol.31
, Issue.2
, pp. 101-111
-
-
Wang, L.T.1
Solberg, T.D.2
Medin, P.M.3
Boone, R.4
-
47
-
-
0037402936
-
Interfractional and intrafractional accuracy during radiotherapy of gynaecologic carcinomas: A comprehensive evaluation using the ExacTrac system
-
Weiss E, Vorwerk H, Richter S and Hess C F 2003 Interfractional and intrafractional accuracy during radiotherapy of gynaecologic carcinomas: a comprehensive evaluation using the ExacTrac system Int. J. Radiat. Oncol. Biol. Phys. 56 69-79
-
(2003)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.56
, Issue.1
, pp. 69-79
-
-
Weiss, E.1
Vorwerk, H.2
Richter, S.3
Hess, C.F.4
-
48
-
-
0035061427
-
Fiducial point placement and the accuracy of point-based, rigid body registration
-
West J B, Fitzpatrick J M, Toms S A, Maurer C R Jr and Maciunas R J 2001 Fiducial point placement and the accuracy of point-based, rigid body registration Neurosurgery 48 810-7
-
(2001)
Neurosurgery
, vol.48
, Issue.4
, pp. 810-817
-
-
West, J.B.1
Fitzpatrick, J.M.2
Toms, S.A.3
Maurer, C.R.4
MacIunas, R.J.5
-
49
-
-
33645347668
-
Overview of image-guided radiation therapy
-
Xing L, Thorndyke B, Schreibmann E, Yang Y, Li T F, Kim G Y, Luxton G and Koong A 2006 Overview of image-guided radiation therapy Med. Dosim. 31 91-112
-
(2006)
Med. Dosim.
, vol.31
, Issue.2
, pp. 91-112
-
-
Xing, L.1
Thorndyke, B.2
Schreibmann, E.3
Yang, Y.4
Li, T.F.5
Kim, G.Y.6
Luxton, G.7
Koong, A.8
-
50
-
-
0031749299
-
The use of adaptive radiation therapy to reduce set-up error: A prospective clinical study
-
Yan D, Ziaja E, Jaffray D, Wong J, Brabbins D, Vicini F and Martinez A 1998 The use of adaptive radiation therapy to reduce set-up error: a prospective clinical study Int. J. Radiat. Oncol. Biol. Phys. 41 715-20
-
(1998)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.41
, Issue.3
, pp. 715-720
-
-
Yan, D.1
Ziaja, E.2
Jaffray, D.3
Wong, J.4
Brabbins, D.5
Vicini, F.6
Martinez, A.7
|