메뉴 건너뛰기




Volumn 33, Issue 4, 2006, Pages 1141-1152

Robust frameless stereotactic localization in extra-cranial radiotherapy

Author keywords

Extra cranial radiotherapy; Frameless stereotaxis; Localization accuracy; Patient positioning

Indexed keywords

ALIGNMENT; CHEMICAL DETECTION; DEGREES OF FREEDOM (MECHANICS); MUSCULOSKELETAL SYSTEM; PATIENT MONITORING; RADIOTHERAPY; TUMORS;

EID: 33645507949     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2181299     Document Type: Article
Times cited : (12)

References (30)
  • 1
    • 0037992520 scopus 로고    scopus 로고
    • Extracranial stereotactic radiation delivery: Expansion of technology beyond the brain
    • R. Timmerman, L. Papiez, and M. Suntharalingam, " Extracranial stereotactic radiation delivery: Expansion of technology beyond the brain., " Technol. Cancer Res. Treat. 2, 153-160 (2003).
    • (2003) Technol. Cancer Res. Treat. , vol.2 , pp. 153-160
    • Timmerman, R.1    Papiez, L.2    Suntharalingam, M.3
  • 2
    • 0035156119 scopus 로고    scopus 로고
    • Infrared patient positioning for stereotactic radiosurgery of extracranial tumors
    • L. T. Wang, T. D. Solberg, P. M. Medin, and R. Boone, " Infrared patient positioning for stereotactic radiosurgery of extracranial tumors., " Comput. Biol. Med. 31, 101-111 (2001).
    • (2001) Comput. Biol. Med. , vol.31 , pp. 101-111
    • Wang, L.T.1    Solberg, T.D.2    Medin, P.M.3    Boone, R.4
  • 3
    • 1142299677 scopus 로고    scopus 로고
    • Prediction of respiratory tumour motion for real-time image-guided radiotherapy
    • G. C. Sharp, S. B. Jiang, S. Shimizu, and H. Shirato, " Prediction of respiratory tumour motion for real-time image-guided radiotherapy., " Phys. Med. Biol. 49, 425-440 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 425-440
    • Sharp, G.C.1    Jiang, S.B.2    Shimizu, S.3    Shirato, H.4
  • 4
    • 0038497901 scopus 로고    scopus 로고
    • An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments
    • S. B. Jiang, C. Pope, K. M. Al Jarrah, J. H. Kung, T. Bortfeld, and G. T. Y. Chen, " An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments., " Phys. Med. Biol. 48, 1773-1784 (2003).
    • (2003) Phys. Med. Biol. , vol.48 , pp. 1773-1784
    • Jiang, S.B.1    Pope, C.2    Al Jarrah, K.M.3    Kung, J.H.4    Bortfeld, T.5    Chen, G.T.Y.6
  • 5
    • 0036535315 scopus 로고    scopus 로고
    • Issues in respiratory motion compensation during external-beam radiotherapy
    • C. Ozhasoglu and M. J. Murphy, " Issues in respiratory motion compensation during external-beam radiotherapy., " Int. J. Radiat. Oncol., Biol., Phys. 52, 1389-1399 (2002).
    • (2002) Int. J. Radiat. Oncol., Biol., Phys. , vol.52 , pp. 1389-1399
    • Ozhasoglu, C.1    Murphy, M.J.2
  • 8
    • 0037377262 scopus 로고    scopus 로고
    • Three-dimensional analysis of delineation errors, setup errors, and organ motion during radiotherapy of bladder cancer
    • G. J. Meijer, C. Rasch, P. Remeijer, and J. V. Lebesque, " Three-dimensional analysis of delineation errors, setup errors, and organ motion during radiotherapy of bladder cancer., " Int. J. Radiat. Oncol., Biol., Phys. 55, 1277-1287 (2003).
    • (2003) Int. J. Radiat. Oncol., Biol., Phys. , vol.55 , pp. 1277-1287
    • Meijer, G.J.1    Rasch, C.2    Remeijer, P.3    Lebesque, J.V.4
  • 9
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • M. van Herk, P. Remeijer, C. Rasch, and J. V. Lebesque, " The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy., " Int. J. Radiat. Oncol., Biol., Phys. 47, 1121-1135 (2000).
    • (2000) Int. J. Radiat. Oncol., Biol., Phys. , vol.47 , pp. 1121-1135
    • Van Herk, M.1    Remeijer, P.2    Rasch, C.3    Lebesque, J.V.4
  • 10
    • 0036127009 scopus 로고    scopus 로고
    • Fiducial-based targeting accuracy for external-beam radiotherapy
    • M. J. Murphy, " Fiducial-based targeting accuracy for external-beam radiotherapy., " Med. Phys. 29, 334-344 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 334-344
    • Murphy, M.J.1
  • 12
    • 0038030020 scopus 로고    scopus 로고
    • Quality assurance of a system for improved target localization and patient setup that combines real-time infrared tracking and stereoscopic x-ray imaging
    • D. Verellen, G. Soete, N. Linthout, S. Van Acker, P. De Roover, V. Vinh-Hung, J. Van de Steene, and G. Storme, " Quality assurance of a system for improved target localization and patient setup that combines real-time infrared tracking and stereoscopic x-ray imaging., " Radiother. Oncol. 67, 129-141 (2003).
    • (2003) Radiother. Oncol. , vol.67 , pp. 129-141
    • Verellen, D.1    Soete, G.2    Linthout, N.3    Van Acker, S.4    De Roover, P.5    Vinh-Hung, V.6    Van De Steene, J.7    Storme, G.8
  • 13
    • 0037402936 scopus 로고    scopus 로고
    • Interfractional and intrafractional accuracy during radiotherapy of gynecologic carcinomas: A comprehensive evaluation using the ExacTrac system
    • E. Weiss, H. Vorwerk, S. Richter, and C. F. Hess, " Interfractional and intrafractional accuracy during radiotherapy of gynecologic carcinomas: A comprehensive evaluation using the ExacTrac system., " Int. J. Radiat. Oncol., Biol., Phys. 56, 69-79 (2003).
    • (2003) Int. J. Radiat. Oncol., Biol., Phys. , vol.56 , pp. 69-79
    • Weiss, E.1    Vorwerk, H.2    Richter, S.3    Hess, C.F.4
  • 17
    • 0038359757 scopus 로고    scopus 로고
    • Stereotactic body frame based fractionated radiosurgery on consecutive days for primary or metastatic tumors in the lung
    • S. W. Lee, E. K. Choi, H. J. Park, S. D. Ahn, J. H. Kim, S. M. Yoon, Y. S. Kim, and B. Y. Yi, " Stereotactic body frame based fractionated radiosurgery on consecutive days for primary or metastatic tumors in the lung., " Lung Cancer 40, 309-315 (2003).
    • (2003) Lung Cancer , vol.40 , pp. 309-315
    • Lee, S.W.1    Choi, E.K.2    Park, H.J.3    Ahn, S.D.4    Kim, J.H.5    Yoon, S.M.6    Kim, Y.S.7    Yi, B.Y.8
  • 18
    • 0032213311 scopus 로고    scopus 로고
    • Implementation and application of real-time motion analysis based on passive markers
    • G. Baroni, G. Ferrigno, and A. Pedotti, " Implementation and application of real-time motion analysis based on passive markers., " Med. Biol. Eng. Comput. 36, 693-703 (1998).
    • (1998) Med. Biol. Eng. Comput. , vol.36 , pp. 693-703
    • Baroni, G.1    Ferrigno, G.2    Pedotti, A.3
  • 19
    • 0033752825 scopus 로고    scopus 로고
    • Real-time opto-electronic verification of patient position in breast cancer radiotherapy
    • G. Baroni, G. Ferrigno, R. Orecchia, and A. Pedotti, " Real-time opto-electronic verification of patient position in breast cancer radiotherapy., " Comput. Aided Surg. 5, 296-306 (2000).
    • (2000) Comput. Aided Surg. , vol.5 , pp. 296-306
    • Baroni, G.1    Ferrigno, G.2    Orecchia, R.3    Pedotti, A.4
  • 20
    • 0033955778 scopus 로고    scopus 로고
    • Real-time three-dimensional motion analysis for patient positioning verification
    • G. Baroni, G. Ferrigno, R. Orecchia, and A. Pedotti, " Real-time three-dimensional motion analysis for patient positioning verification., " Radiother. Oncol. 54, 21-27 (2000).
    • (2000) Radiother. Oncol. , vol.54 , pp. 21-27
    • Baroni, G.1    Ferrigno, G.2    Orecchia, R.3    Pedotti, A.4
  • 21
    • 20644454162 scopus 로고    scopus 로고
    • Emergent technologies for three-dimensional image-guided radiation delivery
    • D. A. Jaffray, " Emergent technologies for three-dimensional image-guided radiation delivery., " Semin. Radiat. Oncol. 15, 208-216 (2005).
    • (2005) Semin. Radiat. Oncol. , vol.15 , pp. 208-216
    • Jaffray, D.A.1
  • 23
    • 22544445828 scopus 로고    scopus 로고
    • Image-guided adaptive radiation therapy (IGART): Radiobiological and dose escalation considerations for localized carcinoma of the prostate
    • W. Song, B. Schaly, G. Bauman, J. Battista, and J. Van Dyk, " Image-guided adaptive radiation therapy (IGART): Radiobiological and dose escalation considerations for localized carcinoma of the prostate., " Med. Phys. 32, 2193-2203 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 2193-2203
    • Song, W.1    Schaly, B.2    Bauman, G.3    Battista, J.4    Van Dyk, J.5
  • 25
    • 20644464960 scopus 로고    scopus 로고
    • Introduction: Management of target localization uncertainties in external-beam therapy
    • G. S. Mageras, " Introduction: Management of target localization uncertainties in external-beam therapy., " Semin. Radiat. Oncol. 15, 133-135 (2005).
    • (2005) Semin. Radiat. Oncol. , vol.15 , pp. 133-135
    • Mageras, G.S.1
  • 27
    • 0035061427 scopus 로고    scopus 로고
    • Fiducial point placement and the accuracy of point-based, rigid body registration
    • J. B. West, J. M. Fitzpatrick, S. A. Toms, C. R. Maurer, Jr., and R. J. Maciunas, " Fiducial point placement and the accuracy of point-based, rigid body registration., " Neurosurgery 48, 810-817 (2001).
    • (2001) Neurosurgery , vol.48 , pp. 810-817
    • West, J.B.1    Fitzpatrick, J.M.2    Toms, S.A.3    Maurer Jr., C.R.4    MacIunas, R.J.5
  • 28
    • 0345099659 scopus 로고    scopus 로고
    • Evaluation of methods for opto-electronic body surface sensing applied to patient position control in breast radiation therapy
    • G. Baroni, A. Troia, M. Riboldi, R. Orecchia, and A. Pedotti, " Evaluation of methods for opto-electronic body surface sensing applied to patient position control in breast radiation therapy., " Med. Biol. Eng. Comput. 41, 679-688 (2003).
    • (2003) Med. Biol. Eng. Comput. , vol.41 , pp. 679-688
    • Baroni, G.1    Troia, A.2    Riboldi, M.3    Orecchia, R.4    Pedotti, A.5
  • 29
    • 0032994668 scopus 로고    scopus 로고
    • Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles
    • U. Della Croce, A. Cappozzo, and D. C. Kerrigan, " Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles., " Med. Biol. Eng. Comput. 37, 155-161 (1999).
    • (1999) Med. Biol. Eng. Comput. , vol.37 , pp. 155-161
    • Della Croce, U.1    Cappozzo, A.2    Kerrigan, D.C.3
  • 30
    • 0036808968 scopus 로고    scopus 로고
    • Self-marking of anatomical landmarks for on-orbit experimental motion analysis compared to export direct-marking
    • M. Rabuffetti, G. Baroni, M. Ferrarin, G. Ferrigno, and A. Pedotti, " Self-marking of anatomical landmarks for on-orbit experimental motion analysis compared to export direct-marking., " Hum. Mov. Sci. 21, 439-455 (2002).
    • (2002) Hum. Mov. Sci. , vol.21 , pp. 439-455
    • Rabuffetti, M.1    Baroni, G.2    Ferrarin, M.3    Ferrigno, G.4    Pedotti, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.