메뉴 건너뛰기




Volumn 47, Issue 5, 2007, Pages 595-607

Measurement of orthopedic cortical bone screw insertion performance in cadaver bone and model materials

Author keywords

Bone screw; Cadaveric analog; Insertion torque; Load; Self tap

Indexed keywords

AXIAL DISPLACEMENT; BONE SCREW; SELF-TAPPING SCREW;

EID: 34748891230     PISSN: 00144851     EISSN: 17412765     Source Type: Journal    
DOI: 10.1007/s11340-007-9056-6     Document Type: Article
Times cited : (16)

References (26)
  • 2
    • 21844480606 scopus 로고    scopus 로고
    • Increase of pullout strength of spinal pedicle screws with conical core: Biomechanical tests and finite element analyses
    • Hsu CC, Chao CK, Wang JL, Hou SM, Tsai YT, Lin J (2005) Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses. J Orthop Res 23(4):788-794.
    • (2005) J Orthop Res , vol.23 , Issue.4 , pp. 788-794
    • Hsu, C.C.1    Chao, C.K.2    Wang, J.L.3    Hou, S.M.4    Tsai, Y.T.5    Lin, J.6
  • 3
    • 0034324072 scopus 로고    scopus 로고
    • Substitutes for human cadaveric bone in maxillofacial rigid fixation research
    • Bredbenner TL, Haug RH (2000) Substitutes for human cadaveric bone in maxillofacial rigid fixation research. Oral Surg Oral Med Oral Pathol Oral Radiol Endo 90(5):574-580.
    • (2000) Oral Surg Oral Med Oral Pathol Oral Radiol Endo , vol.90 , Issue.5 , pp. 574-580
    • Bredbenner, T.L.1    Haug, R.H.2
  • 4
    • 4544343314 scopus 로고    scopus 로고
    • Insertion torque and pullout force of rescue screws for anterior cervical plate fixation in a fatigued initial pilot hole
    • Pitzen T, Franta F, Barbier D, Steudel WI (2004) Insertion torque and pullout force of rescue screws for anterior cervical plate fixation in a fatigued initial pilot hole. J Neurosurg Spine 1(2):198-201.
    • (2004) J Neurosurg Spine , vol.1 , Issue.2 , pp. 198-201
    • Pitzen, T.1    Franta, F.2    Barbier, D.3    Steudel, W.I.4
  • 5
    • 0344431272 scopus 로고    scopus 로고
    • Moments and forces during pedicle screw insertion. In vitro and in vivo measurements
    • discussion 1228
    • Buhler DW, Berlemann U, Oxland TR, Nolte LP (1998) Moments and forces during pedicle screw insertion. In vitro and in vivo measurements. Spine 23(11):1220-1227; discussion 1228.
    • (1998) Spine , vol.23 , Issue.11 , pp. 1220-1227
    • Buhler, D.W.1    Berlemann, U.2    Oxland, T.R.3    Nolte, L.P.4
  • 6
    • 0242551810 scopus 로고    scopus 로고
    • Mechanical testing of small fracture implants for comparison of insertion and failure torques
    • Glauser CR, Oden ZM, Ambrose CG, Willits MB, Coupe KJ (2003) Mechanical testing of small fracture implants for comparison of insertion and failure torques. Arch Orthop Trauma Surg 123(8):388-391.
    • (2003) Arch Orthop Trauma Surg , vol.123 , Issue.8 , pp. 388-391
    • Glauser, C.R.1    Oden, Z.M.2    Ambrose, C.G.3    Willits, M.B.4    Coupe, K.J.5
  • 7
    • 0035000837 scopus 로고    scopus 로고
    • Effect of insertion torque on bone screw pullout strength
    • Lawson KJ, Brems J (2001) Effect of insertion torque on bone screw pullout strength. Orthopedics 24(5):451-454.
    • (2001) Orthopedics , vol.24 , Issue.5 , pp. 451-454
    • Lawson, K.J.1    Brems, J.2
  • 8
    • 0035291060 scopus 로고    scopus 로고
    • Effect of cutting flute design on cortical bone screw insertion torque and pullout strength
    • Yerby S, Scott CC, Evans NJ, Messing KL, Carter DR (2001) Effect of cutting flute design on cortical bone screw insertion torque and pullout strength. J Orthop Trauma 15(3):216-221.
    • (2001) J Orthop Trauma , vol.15 , Issue.3 , pp. 216-221
    • Yerby, S.1    Scott, C.C.2    Evans, N.J.3    Messing, K.L.4    Carter, D.R.5
  • 9
    • 4043175645 scopus 로고    scopus 로고
    • Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine
    • Reitman CA, Nguyen L, Fogel GR (2004) Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine. J Spinal Disord Tech 17(4):306-311.
    • (2004) J Spinal Disord Tech , vol.17 , Issue.4 , pp. 306-311
    • Reitman, C.A.1    Nguyen, L.2    Fogel, G.R.3
  • 10
    • 18144365485 scopus 로고    scopus 로고
    • Effect of bone mineral density and amorphous diamond coatings on insertion torque of bone screws
    • Koistinen A, Santavirta SS, Kroger H, Lappalainen R (2005) Effect of bone mineral density and amorphous diamond coatings on insertion torque of bone screws. Biomaterials 26(28):5687-5694.
    • (2005) Biomaterials , vol.26 , Issue.28 , pp. 5687-5694
    • Koistinen, A.1    Santavirta, S.S.2    Kroger, H.3    Lappalainen, R.4
  • 11
    • 1442330815 scopus 로고    scopus 로고
    • Apparatus to test insertion and removal torque of bone screws
    • Koistinen A, Santavirta S, Lappalainen R (2003) Apparatus to test insertion and removal torque of bone screws. Proc Inst Mech Eng H 217(6):503-508.
    • (2003) Proc Inst Mech Eng H , vol.217 , Issue.6 , pp. 503-508
    • Koistinen, A.1    Santavirta, S.2    Lappalainen, R.3
  • 12
    • 0015378503 scopus 로고
    • The mechanical properties of surgical bone screws and some aspects of insertion practice
    • Hughes AN, Jordan BA (1972) The mechanical properties of surgical bone screws and some aspects of insertion practice. Injury 4(1):25-38.
    • (1972) Injury , vol.4 , Issue.1 , pp. 25-38
    • Hughes, A.N.1    Jordan, B.A.2
  • 13
    • 0028914440 scopus 로고
    • "Analysis of the torque applied to bone screws by trauma surgeons. Comparisons based on years of experience and material of implant construction"
    • McGuire RA, St John KR, Agnew SG (1995) "Analysis of the torque applied to bone screws by trauma surgeons. Comparisons based on years of experience and material of implant construction." Am J Orthop 24(3):254-256.
    • (1995) Am J Orthop , vol.24 , Issue.3 , pp. 254-256
    • McGuire, R.A.1    St John, K.R.2    Agnew, S.G.3
  • 15
    • 0000781654 scopus 로고
    • "A study of some factors which affect the strength of screws and their insertion and holding power in bone"
    • Ansell RH, Scales JT (1968) "A study of some factors which affect the strength of screws and their insertion and holding power in bone." J Biomech 1(4):279-302.
    • (1968) J Biomech , vol.1 , Issue.4 , pp. 279-302
    • Ansell, R.H.1    Scales, J.T.2
  • 16
    • 0029101673 scopus 로고
    • Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screws
    • Ryken TC, Clausen JD, Traynelis VC, Goel VK (1995) Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screws. J Neurosurg 83(2):325-329.
    • (1995) J Neurosurg , vol.83 , Issue.2 , pp. 325-329
    • Ryken, T.C.1    Clausen, J.D.2    Traynelis, V.C.3    Goel, V.K.4
  • 17
    • 0018609372 scopus 로고
    • Bone-mineral content, surface hardness, and mechanical fixation in the human radius: A correlative study
    • Trader JE, Johnson RP, Kalbfleisch JH (1979) Bone-mineral content, surface hardness, and mechanical fixation in the human radius: A correlative study. J Bone Joint Surg Am 61(8):1217-1220.
    • (1979) J Bone Joint Surg Am , vol.61 , Issue.8 , pp. 1217-1220
    • Trader, J.E.1    Johnson, R.P.2    Kalbfleisch, J.H.3
  • 18
    • 0017145755 scopus 로고
    • Force measurements in screw fixation
    • Nunamaker DM, Perren SM (1976) Force measurements in screw fixation. J Biomech 9(11):669-675.
    • (1976) J Biomech , vol.9 , Issue.11 , pp. 669-675
    • Nunamaker, D.M.1    Perren, S.M.2
  • 19
    • 0013887585 scopus 로고
    • The microscopic hardness of bone
    • Weaver JK (1966) The microscopic hardness of bone. J Bone Joint Surg Am 48(2):273-288.
    • (1966) J Bone Joint Surg Am , vol.48 , Issue.2 , pp. 273-288
    • Weaver, J.K.1
  • 20
    • 34748907011 scopus 로고    scopus 로고
    • Zimmer, Inc. Sales Data on file at Zimmer, Inc
    • Zimmer, Inc. (2004-2006) Sales Data on file at Zimmer, Inc.
    • (2004)
  • 21
    • 34748880455 scopus 로고    scopus 로고
    • CELCON® (M25 Grade) Ticona, Florence, KY
    • CELCON® (M25 Grade) (2004) Material Properties Datasheet, Ticona, Florence, KY.
    • (2004) Material Properties Datasheet
  • 22
    • 33750282473 scopus 로고
    • Atlas of mechanical properties of human cortical and cancellous bone
    • In: Van Der Perre G, Lowet G, Borgwardt-Christensen A (eds) Durham, UK
    • Hobatho MC, Rho JY, Ashman RB (1991) Atlas of mechanical properties of human cortical and cancellous bone. In: Van Der Perre G, Lowet G, Borgwardt-Christensen A (eds) Proceedings COMAC-BME 11.2.6 meeting. Durham, UK, pp 11-13.
    • (1991) Proceedings COMAC-BME 11.2.6 Meeting , pp. 11-13
    • Hobatho, M.C.1    Rho, J.Y.2    Ashman, R.B.3
  • 23
    • 0004207761 scopus 로고
    • Chapter 6. CRC Press, New York
    • Cowin S (1989) Bone mechanics, Chapter 6. CRC Press, New York, pp 97-158.
    • (1989) Bone Mechanics , pp. 97-158
    • Cowin, S.1
  • 25
    • 34748880455 scopus 로고    scopus 로고
    • FR 3720 General Plastics Manufacturing Co., Tacoma, WA
    • FR 3720 (2004) Material properties datasheet. General Plastics Manufacturing Co., Tacoma, WA.
    • (2004) Material Properties Datasheet
  • 26
    • 34748857187 scopus 로고    scopus 로고
    • Specification for rigid polyurethane foam for use as a standard material for testing orthopaedic devices and instruments
    • ASTM F1839 American Society for Testing & Materials (ASTM), West Conshohocken, PA
    • ASTM F1839 (2004) Specification for rigid polyurethane foam for use as a standard material for testing orthopaedic devices and instruments. American Society for Testing & Materials (ASTM), West Conshohocken, PA.
    • (2004)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.