메뉴 건너뛰기




Volumn 46, Issue 4, 2007, Pages 773-779

Assessment of three-dimensional stent-graft dynamics by using fluoroscopic roentgenographic stereophotogrammetric analysis

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ANEURYSM SURGERY; ANIMAL TISSUE; ARTICLE; BLOOD VESSEL GRAFT; ENDOVASCULAR SURGERY; FLUOROSCOPIC ROENTGENOGRAPHIC STEREOPHOTOGRAMMETRIC ANALYSIS; FLUOROSCOPY; IMAGE ANALYSIS; IMAGING SYSTEM; MOTION; NONHUMAN; PRIORITY JOURNAL; STENT; SWINE; THORACIC AORTA; THREE DIMENSIONAL IMAGING;

EID: 34548827959     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvs.2007.05.054     Document Type: Article
Times cited : (13)

References (17)
  • 2
    • 0037280213 scopus 로고    scopus 로고
    • Mechanical failure of prosthetic human implants: a 10-year experience with aortic stent graft devices
    • Jacobs T.S., Won J., Gravereaux E.C., Faries P.L., Morrissey N., Teodorescu V.J., et al. Mechanical failure of prosthetic human implants: a 10-year experience with aortic stent graft devices. J Vasc Surg 37 (2003) 16-26
    • (2003) J Vasc Surg , vol.37 , pp. 16-26
    • Jacobs, T.S.1    Won, J.2    Gravereaux, E.C.3    Faries, P.L.4    Morrissey, N.5    Teodorescu, V.J.6
  • 3
    • 33847189726 scopus 로고    scopus 로고
    • Dynamic CTA for cutting edge AAA imaging: insights into aortic distensibility and movement with possible consequences for endograft sizing and stent design
    • Verhagen H.J., Teutelink A., Olree M., Rutten A., de Vos A.M., Raaijmakers R., et al. Dynamic CTA for cutting edge AAA imaging: insights into aortic distensibility and movement with possible consequences for endograft sizing and stent design. J Endovasc Ther 12 (2005) I-45
    • (2005) J Endovasc Ther , vol.12
    • Verhagen, H.J.1    Teutelink, A.2    Olree, M.3    Rutten, A.4    de Vos, A.M.5    Raaijmakers, R.6
  • 4
    • 33750101082 scopus 로고    scopus 로고
    • Pilot study of dynamic cine CT angiography for the evaluation of abdominal aortic aneurysms: implications for endograft treatment
    • Teutelink A., Rutten A., Muhs B.E., Olree M., van Herwaarden J.A., de Vos A.M., et al. Pilot study of dynamic cine CT angiography for the evaluation of abdominal aortic aneurysms: implications for endograft treatment. J Endovasc Ther 13 (2006) 139-144
    • (2006) J Endovasc Ther , vol.13 , pp. 139-144
    • Teutelink, A.1    Rutten, A.2    Muhs, B.E.3    Olree, M.4    van Herwaarden, J.A.5    de Vos, A.M.6
  • 6
    • 0024388994 scopus 로고
    • Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system
    • Selvik G. Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl 232 (1989) 1-51
    • (1989) Acta Orthop Scand Suppl , vol.232 , pp. 1-51
    • Selvik, G.1
  • 7
    • 0024317955 scopus 로고
    • Roentgen stereophotogrammetry. Review of orthopedic applications
    • Karrholm J. Roentgen stereophotogrammetry. Review of orthopedic applications. Acta Orthop Scand 60 (1989) 491-503
    • (1989) Acta Orthop Scand , vol.60 , pp. 491-503
    • Karrholm, J.1
  • 9
  • 11
    • 0037692766 scopus 로고    scopus 로고
    • A new model-based RSA method validated using CAD models and models from reversed engineering
    • Kaptein B.L., Valstar E.R., Stoel B.C., Rozing P.M., and Reiber J.A.C. A new model-based RSA method validated using CAD models and models from reversed engineering. J Biomech 36 (2003) 873-882
    • (2003) J Biomech , vol.36 , pp. 873-882
    • Kaptein, B.L.1    Valstar, E.R.2    Stoel, B.C.3    Rozing, P.M.4    Reiber, J.A.C.5
  • 13
    • 33847219990 scopus 로고    scopus 로고
    • Accurate detection of stentgraft migration in a pulsatile aorta using roentgen stereophotogrammetric analysis
    • Koning O.H., Garling E.H., Hinnen J.W., Kroft L.J., van der Linden E., Hamming J.F., et al. Accurate detection of stentgraft migration in a pulsatile aorta using roentgen stereophotogrammetric analysis. J Endovasc Ther 14 (2007) 30-38
    • (2007) J Endovasc Ther , vol.14 , pp. 30-38
    • Koning, O.H.1    Garling, E.H.2    Hinnen, J.W.3    Kroft, L.J.4    van der Linden, E.5    Hamming, J.F.6
  • 15
    • 13944265711 scopus 로고    scopus 로고
    • Aneurysm sac pressure monitoring: effect of technique on interpretation of measurements
    • Hinnen J.W., Visser M.J., and Van Bockel J.H. Aneurysm sac pressure monitoring: effect of technique on interpretation of measurements. Eur J Vasc Endovasc Surg 29 (2005) 233-238
    • (2005) Eur J Vasc Endovasc Surg , vol.29 , pp. 233-238
    • Hinnen, J.W.1    Visser, M.J.2    Van Bockel, J.H.3
  • 16
    • 0034754030 scopus 로고    scopus 로고
    • Micromovements at the aortic aneurysm neck measured during open surgery with close-range photogrammetry: implications for aortic endografts
    • Flora H.S., Woodhouse N., Robson S., and Adiseshiah M. Micromovements at the aortic aneurysm neck measured during open surgery with close-range photogrammetry: implications for aortic endografts. J Endovasc Ther 8 (2001) 511-520
    • (2001) J Endovasc Ther , vol.8 , pp. 511-520
    • Flora, H.S.1    Woodhouse, N.2    Robson, S.3    Adiseshiah, M.4
  • 17
    • 33846209176 scopus 로고    scopus 로고
    • Validation of a low-dose hybrid RSA and fluoroscopy technique: determination of accuracy, bias and precision
    • Ioppolo J., Borlin N., Bragdon C., Li M., Price R., Wood D., et al. Validation of a low-dose hybrid RSA and fluoroscopy technique: determination of accuracy, bias and precision. J Biomech 40 (2007) 686-692
    • (2007) J Biomech , vol.40 , pp. 686-692
    • Ioppolo, J.1    Borlin, N.2    Bragdon, C.3    Li, M.4    Price, R.5    Wood, D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.