메뉴 건너뛰기




Volumn 29, Issue 3, 2005, Pages 233-238

Aneurysm sac pressure monitoring: Effect of technique on interpretation of measurements

Author keywords

AAA; Aneurysmal sac pressure; EVAR; Pressure sensor

Indexed keywords

STARCH;

EID: 13944265711     PISSN: 10785884     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejvs.2004.11.016     Document Type: Article
Times cited : (9)

References (12)
  • 1
    • 0030072894 scopus 로고    scopus 로고
    • Endoleak - A proposed new terminology to describe incomplete aneurysm exclusion by an endoluminal graft
    • G.H. White W. Yu J. May Endoleak - a proposed new terminology to describe incomplete aneurysm exclusion by an endoluminal graft J Endovasc Surg 3 1996 124-125
    • (1996) J. Endovasc. Surg. , vol.3 , pp. 124-125
    • White, G.H.1    Yu, W.2    May, J.3
  • 3
    • 0035099474 scopus 로고    scopus 로고
    • Thrombus within an aortic aneurysm does not reduce pressure on the aneurysmal wall
    • G.W. Schurink J.M. van Baalen M.J. Visser J.H. van Bockel Thrombus within an aortic aneurysm does not reduce pressure on the aneurysmal wall J Vasc Surg 33 3 2001 660-661
    • (2001) J. Vasc. Surg. , vol.33 , Issue.3 , pp. 660-661
    • Schurink, G.W.1    van Baalen, J.M.2    Visser, M.J.3    van Bockel, J.H.4
  • 5
    • 0031259907 scopus 로고    scopus 로고
    • Canine model of abdominal aortic aneurysm treated by endovascular graft implantation
    • T.A. Chuter S. Viscomi J.L. Slater R. Nowygrod B. Risberg Canine model of abdominal aortic aneurysm treated by endovascular graft implantation Cardiovasc Surg 5 5 1997 490-496
    • (1997) Cardiovasc. Surg. , vol.5 , Issue.5 , pp. 490-496
    • Chuter, T.A.1    Viscomi, S.2    Slater, J.L.3    Nowygrod, R.4    Risberg, B.5
  • 6
    • 0035461310 scopus 로고    scopus 로고
    • Pressure measurements in closed aneurysmal sac during abdominal aortic aneurysm resection
    • S.S. Hans O. Jareunpoon R.R. Huang Pressure measurements in closed aneurysmal sac during abdominal aortic aneurysm resection J Vasc Surg 34 3 2001 519-525
    • (2001) J. Vasc. Surg. , vol.34 , Issue.3 , pp. 519-525
    • Hans, S.S.1    Jareunpoon, O.2    Huang, R.R.3
  • 7
    • 0345505741 scopus 로고    scopus 로고
    • Intra-aneurysm pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair
    • B. Sonesson N. Dias M. Malina P. Olofsson D. Griffin B. Lindblad K. Ivancev Intra-aneurysm pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair J Vasc Surg 37 2003 733-738
    • (2003) J. Vasc. Surg. , vol.37 , pp. 733-738
    • Sonesson, B.1    Dias, N.2    Malina, M.3    Olofsson, P.4    Griffin, D.5    Lindblad, B.6    Ivancev, K.7
  • 8
    • 4444230542 scopus 로고    scopus 로고
    • First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms
    • S.H. Ellozy A. Carroccio R.A. Lookstein M.E. Minor C.M. Sheahan J. Juta et al. First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms J Vasc Surg 40 2004 405-412
    • (2004) J. Vasc. Surg. , vol.40 , pp. 405-412
    • Ellozy, S.H.1    Carroccio, A.2    Lookstein, R.A.3    Minor, M.E.4    Sheahan, C.M.5    Juta, J.6
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • J.M. Bland D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 8476 1986 307-310
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 3242716166 scopus 로고    scopus 로고
    • Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: Differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks
    • N. Dias K. Ivancev M. Malina T. Resch B. Lindblad B. Sonesson Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: Differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks J Vasc Surg 39 2004 1229-1235
    • (2004) J. Vasc. Surg. , vol.39 , pp. 1229-1235
    • Dias, N.1    Ivancev, K.2    Malina, M.3    Resch, T.4    Lindblad, B.5    Sonesson, B.6
  • 12
    • 13944277577 scopus 로고    scopus 로고
    • Pressure sensor for use in an artery
    • US Patent
    • Van Bockel JH. Pressure sensor for use in an artery. US Patent; 2000.
    • (2000)
    • Van Bockel, J.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.