메뉴 건너뛰기




Volumn , Issue , 2007, Pages

A methodology for optimum sensor localization/selection in fault diagnosis

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; FAILURE ANALYSIS; MAINTENANCE; REAL TIME CONTROL; ROBUST CONTROL; STRUCTURAL HEALTH MONITORING;

EID: 34548760151     PISSN: 1095323X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/AERO.2007.352878     Document Type: Conference Paper
Times cited : (20)

References (19)
  • 2
    • 0034841308 scopus 로고    scopus 로고
    • Aeroelastic vehicle optimal sensor placement for feedback control applications using mixed gain-phase stability
    • A. G. Al-Shehabi and Brett Newman, "Aeroelastic vehicle optimal sensor placement for feedback control applications using mixed gain-phase stability," in Proceedings of the American Control Conference, June 2001, vol. 3, pp. 1848-1852.
    • (2001) Proceedings of the American Control Conference, June , vol.3 , pp. 1848-1852
    • Al-Shehabi, A.G.1    Newman, B.2
  • 6
    • 0030782486 scopus 로고    scopus 로고
    • A Disturbance Rejection Approach to Actuator and Sensor Placement
    • January-February
    • K. B. Lim, "A Disturbance Rejection Approach to Actuator and Sensor Placement," Journal of Guidance, Control and Dynamics, vol. 20, no. 1, pp. 202-204, January-February 1997.
    • (1997) Journal of Guidance, Control and Dynamics , vol.20 , Issue.1 , pp. 202-204
    • Lim, K.B.1
  • 7
    • 0033689877 scopus 로고    scopus 로고
    • Sensor placement strategy for In-Situ bearing defect detection
    • th IEEE, vol. 3, 2000, pp. 1463-1467.
    • (2000) th IEEE , vol.3 , pp. 1463-1467
    • Wang, C.1    Gao, R.X.2
  • 8
    • 0034547353 scopus 로고    scopus 로고
    • Optimal sensor location in closed-loop control systems for fault detection and isolation
    • Yonghua Xu and Jin Jiang, "Optimal sensor location in closed-loop control systems for fault detection and isolation," in Proceedings of the American Control Conference, 2000, vol. 2, pp. 1195-1199.
    • (2000) Proceedings of the American Control Conference , vol.2 , pp. 1195-1199
    • Yonghua, X.1    Jiang, J.2
  • 9
    • 0033083172 scopus 로고    scopus 로고
    • Locating sensors in complex chemical plants based on fault diagnostic observability criteria
    • R. Raghuraj, M. Bhushan, and R. Rengaswamy, "Locating sensors in complex chemical plants based on fault diagnostic observability criteria," AIChE Journal, Vol. 45, No.2, pp. 310-322, 1999.
    • (1999) AIChE Journal , vol.45 , Issue.2 , pp. 310-322
    • Raghuraj, R.1    Bhushan, M.2    Rengaswamy, R.3
  • 11
    • 0034661236 scopus 로고    scopus 로고
    • Design of Sensor Location Based on Various Fault Diagnostic Observability and reliability Criteria
    • Mani Bhushan, Raghunathan Rengaswamy, "Design of Sensor Location Based on Various Fault Diagnostic Observability and reliability Criteria," Computers and Chemical Engineering, vol. 24, pp. 735-741, 2000.
    • (2000) Computers and Chemical Engineering , vol.24 , pp. 735-741
    • Bhushan, M.1    Rengaswamy, R.2
  • 12
    • 0028338065 scopus 로고
    • Optimal Selection of Sensor Location on a Complex Plant, Using a Graph Oriented Approach
    • M. Meyer, J. M. Lelann, B.Koehret, M. Enjalbert, "Optimal Selection of Sensor Location on a Complex Plant, Using a Graph Oriented Approach," Computers Chem. Engineering, vol. 18, pp. 8535-8540, 1994.
    • (1994) Computers Chem. Engineering , vol.18 , pp. 8535-8540
    • Meyer, M.1    Lelann, J.M.2    Koehret, B.3    Enjalbert, M.4
  • 13
    • 0036590883 scopus 로고    scopus 로고
    • On the Theory of Optimal Sensor Placement
    • May
    • Donald J. Chmielewski, Tasha Palmer, and Vasilios Manousiouthakis, "On the Theory of Optimal Sensor Placement," AIChE Journal, vol. 48, no.5, pp. 1001-1012, May 2002.
    • (2002) AIChE Journal , vol.48 , Issue.5 , pp. 1001-1012
    • Chmielewski, D.J.1    Palmer, T.2    Manousiouthakis, V.3
  • 14
    • 84987446071 scopus 로고
    • Sensor Network Design for Maximizing Reliability of Linear Processes
    • May
    • Yaqoob Ali and Shankar Narasimhan, "Sensor Network Design for Maximizing Reliability of Linear Processes," Process System Engineering, vol. 39, no. 5, pp. 820-828, May 1993,
    • (1993) Process System Engineering , vol.39 , Issue.5 , pp. 820-828
    • Ali, Y.1    Narasimhan, S.2
  • 15
    • 0023383125 scopus 로고
    • A rule-based approach to fault diagnosis using the signed directed graph
    • Kramer, M. A.; Palowitch, B. L. J. A rule-based approach to fault diagnosis using the signed directed graph. AIChE J. 1987, 33 (7), 1067.
    • (1987) AIChE J , vol.33 , Issue.7 , pp. 1067
    • Kramer, M.A.1    Palowitch, B.L.J.2
  • 16
    • 0003325855 scopus 로고
    • Systematic development of causal digraph models for chemical processes part I: General framework
    • San Francisco, CA
    • Mylaraswamy, D.; Kavuri, S. N.; Venkatasubramanian, V. Systematic development of causal digraph models for chemical processes part I: general framework. In AIChE Meeting, San Francisco, CA, 1994.
    • (1994) AIChE Meeting
    • Mylaraswamy, D.1    Kavuri, S.N.2    Venkatasubramanian, V.3
  • 17
    • 34548713506 scopus 로고    scopus 로고
    • Bhushan, M. and Rengaswamy, R. Design of sensor network based on the signed directed graph of the process for efficient fault diagnosis
    • Bhushan, M. and Rengaswamy, R. Design of sensor network based on the signed directed graph of the process for efficient fault diagnosis
  • 19
    • 0027507163 scopus 로고
    • A simple design strategy for fault monitoring systems
    • Chang, C. T.; Mah, K. N.; Tsai, C. S. A simple design strategy for fault monitoring systems. AIChE J. 1993, 39(7), 1146.
    • (1993) AIChE J , vol.39 , Issue.7 , pp. 1146
    • Chang, C.T.1    Mah, K.N.2    Tsai, C.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.