메뉴 건너뛰기




Volumn 21, Issue 5, 2007, Pages 277-282

Impact of withdrawal of 450 ml of blood on respiration-induced oscillations of the ear plethysmographic waveform

Author keywords

Hemodynamic monitoring; Non invasive monitoring; Photoplethysmograph

Indexed keywords

BLOOD PRESSURE; HEMODYNAMICS; NONINVASIVE MEDICAL PROCEDURES; PLETHYSMOGRAPHY;

EID: 34548628410     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-007-9085-9     Document Type: Article
Times cited : (29)

References (32)
  • 1
    • 0036606336 scopus 로고    scopus 로고
    • Paradoxical physical findings described by kussmaul: Pulsus paradoxus, kussmaul's sign
    • Bilchick KC, Wise RA. Paradoxical physical findings described by kussmaul: Pulsus paradoxus, kussmaul's sign. Lancet 2002; 359: 1940-2
    • (2002) Lancet , vol.359 , pp. 1940-1942
    • Bilchick, K.C.1    Wise, R.A.2
  • 4
    • 23044461875 scopus 로고    scopus 로고
    • Changes in arterial pressure during mechanical ventilation
    • Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology 2005; 103: 419-28
    • (2005) Anesthesiology , vol.103 , pp. 419-428
    • Michard, F.1
  • 5
    • 0014478289 scopus 로고
    • The hemodynamic effects of changes in blood volume during intermittent positive-pressure ventilation
    • Morgan B, Crawford W, Guntheroth W. The hemodynamic effects of changes in blood volume during intermittent positive-pressure ventilation. Anesthesiology 1969; 30: 297-305
    • (1969) Anesthesiology , vol.30 , pp. 297-305
    • Morgan, B.1    Crawford, W.2    Guntheroth, W.3
  • 6
    • 0023605206 scopus 로고
    • Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage
    • Perel A, Pizov R, Cotev S. Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology 1987; 67: 498-502
    • (1987) Anesthesiology , vol.67 , pp. 498-502
    • Perel, A.1    Pizov, R.2    Cotev, S.3
  • 7
    • 0023930849 scopus 로고
    • Systolic pressure variation is greater during hemorrhage than during sodium nitroprusside-induced hypotension in ventilated dogs
    • Pizov R, Ya'ari Y, Perel A. Systolic pressure variation is greater during hemorrhage than during sodium nitroprusside-induced hypotension in ventilated dogs. Anesth Analg 1988; 67: 170-4
    • (1988) Anesth Analg , vol.67 , pp. 170-174
    • Pizov, R.1    Ya'ari, Y.2    Perel, A.3
  • 8
    • 0024343884 scopus 로고
    • The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs
    • Szold A, Pizov R, Segal E, Perel A. The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs. Intensive Care Med 1989; 15: 368-71
    • (1989) Intensive Care Med , vol.15 , pp. 368-371
    • Szold, A.1    Pizov, R.2    Segal, E.3    Perel, A.4
  • 9
    • 0025697098 scopus 로고
    • The use of systolic pressure variation in hemodynamic monitoring during deliberate hypotension in spine surgery
    • Pizov R, Segal E, Kaplan L, Floman Y, Perel A. The use of systolic pressure variation in hemodynamic monitoring during deliberate hypotension in spine surgery. J Clin Anesth 1990; 2: 96-100
    • (1990) J Clin Anesth , vol.2 , pp. 96-100
    • Pizov, R.1    Segal, E.2    Kaplan, L.3    Floman, Y.4    Perel, A.5
  • 10
    • 9544228424 scopus 로고    scopus 로고
    • The effectiveness of right heart catheterization in the initial care of critically ill patients
    • Connors A, Speroff T, Dawson N. The effectiveness of right heart catheterization in the initial care of critically ill patients. JAMA 1996; 276: 889-97
    • (1996) JAMA , vol.276 , pp. 889-897
    • Connors, A.1    Speroff, T.2    Dawson, N.3
  • 11
    • 0027272907 scopus 로고
    • The systolic blood pressure variation as an indicator of pulmonary capillary wedge pressure in ventilated patients
    • Marik PE. The systolic blood pressure variation as an indicator of pulmonary capillary wedge pressure in ventilated patients. Anaesth Intensive Care 1993; 21: 405-8
    • (1993) Anaesth Intensive Care , vol.21 , pp. 405-408
    • Marik, P.E.1
  • 12
  • 13
    • 0007612640 scopus 로고
    • Cardiovascular assessment by pressure waveform analysis
    • Perel A. Cardiovascular assessment by pressure waveform analysis. ASA Annual Refresher Course Lecture 1991:264
    • (1991) ASA Annual Refresher Course Lecture , vol.264
    • Perel, A.1
  • 14
    • 28844464011 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in patients undergoing cardiac surgery: Functional haemodynamic parameters including the respiratory systolic variation test and static preload indicators
    • Preisman S, Kogan S, Berkenstadt H, Perel A. Predicting fluid responsiveness in patients undergoing cardiac surgery: Functional haemodynamic parameters including the respiratory systolic variation test and static preload indicators. Br J Anaesth 2005; 95: 746-55
    • (2005) Br J Anaesth , vol.95 , pp. 746-755
    • Preisman, S.1    Kogan, S.2    Berkenstadt, H.3    Perel, A.4
  • 15
    • 0028906057 scopus 로고
    • The effect of graded hemorrhage and intravascular volume replacement on systolic pressure variation in humans during mechanical and spontaneous ventilation
    • Rooke GA, Schwid HA, Shapira Y. The effect of graded hemorrhage and intravascular volume replacement on systolic pressure variation in humans during mechanical and spontaneous ventilation. Anesth Analg 1995; 80: 925-32
    • (1995) Anesth Analg , vol.80 , pp. 925-932
    • Rooke, G.A.1    Schwid, H.A.2    Shapira, Y.3
  • 16
    • 16344364138 scopus 로고    scopus 로고
    • Variation of "Pulse amplitude" Measured by a pulse oximeter may help predict intravascular volume
    • Yamakage M, Itoh T, Iwasaki S, Jeong S-W, Namiki A. Variation of "Pulse amplitude" Measured by a pulse oximeter may help predict intravascular volume Can J Anaesth 2005; 52: 207-8
    • (2005) Can J Anaesth , vol.52 , pp. 207-208
    • Yamakage, M.1    Itoh, T.2    Iwasaki, S.3    Jeong, S.-W.4    Namiki, A.5
  • 17
  • 18
    • 0021797791 scopus 로고
    • Photo-electric plethysmography as a monitoring device in anaesthesia. Application and interpretation
    • Dorlas JC, Nijboer JA. Photo-electric plethysmography as a monitoring device in anaesthesia. Application and interpretation. Br J Anaesth 1985; 57: 524-30
    • (1985) Br J Anaesth , vol.57 , pp. 524-530
    • Dorlas, J.C.1    Nijboer, J.A.2
  • 19
    • 0032924608 scopus 로고    scopus 로고
    • Estimation of respiratory volumes from the photoplethysmographic signal. Part i: Experimental results
    • Johansson A, Oberg PA. Estimation of respiratory volumes from the photoplethysmographic signal. Part i: Experimental results. Med Biol Eng Comput 1999; 37: 42-7
    • (1999) Med Biol Eng Comput , vol.37 , pp. 42-47
    • Johansson, A.1    Oberg, P.A.2
  • 20
    • 34548634048 scopus 로고
    • Correlation between plethysmography curve variation (dpleth), pulmonary capillary wedge pressure (pcwp) in mechanically ventilated patients
    • Lherm T, Chevalier T, Troche G, Souron V, Samaha T, Zazzo J. Correlation between plethysmography curve variation (dpleth), pulmonary capillary wedge pressure (pcwp) in mechanically ventilated patients. Br J Anaesth 1995; Suppl. 1: 41
    • (1995) Br J Anaesth , Issue.SUPPL. 1 , pp. 41
    • Lherm, T.1    Chevalier, T.2    Troche, G.3    Souron, V.4    Samaha, T.5    Zazzo, J.6
  • 21
    • 0023428633 scopus 로고
    • Use of pulse oximetry as a noninvasive indicator of intravascular volume status
    • Partridge BL. Use of pulse oximetry as a noninvasive indicator of intravascular volume status. J Clin Monit 1987; 3: 263-8
    • (1987) J Clin Monit , vol.3 , pp. 263-268
    • Partridge, B.L.1
  • 22
    • 0032953278 scopus 로고    scopus 로고
    • Pulse oximetry plethysmographic waveform during changes in blood volume
    • Shamir M, Eidelman LA, Floman Y, Kaplan L, Pizov R. Pulse oximetry plethysmographic waveform during changes in blood volume. Br J Anaesth 1999; 82: 178-81
    • (1999) Br J Anaesth , vol.82 , pp. 178-181
    • Shamir, M.1    Eidelman, L.A.2    Floman, Y.3    Kaplan, L.4    Pizov, R.5
  • 23
    • 0036896131 scopus 로고    scopus 로고
    • Evaluating the relationship between arterial blood pressure changes and indices of pulse oximetric plethysmography
    • Golparvar M, Naddafnia H, Saghaei M. Evaluating the relationship between arterial blood pressure changes and indices of pulse oximetric plethysmography. Anesth Analg 2002; 95: 1686-90
    • (2002) Anesth Analg , vol.95 , pp. 1686-1690
    • Golparvar, M.1    Naddafnia, H.2    Saghaei, M.3
  • 25
    • 0000696490 scopus 로고
    • The blood supply of various skin areas as estimated by the photoelectric plethysmograph
    • Hertzman AB. The blood supply of various skin areas as estimated by the photoelectric plethysmograph. Am J Physiol 1938; 124: 328-40
    • (1938) Am J Physiol , vol.124 , pp. 328-340
    • Hertzman, A.B.1
  • 27
    • 33745121601 scopus 로고    scopus 로고
    • The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform
    • Shelley KH, Awad AA, Stout RG, Silverman DG. The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform. J Clin Monit Comput 2006; 20: 81-7
    • (2006) J Clin Monit Comput , vol.20 , pp. 81-87
    • Shelley, K.H.1    Awad, A.A.2    Stout, R.G.3    Silverman, D.G.4
  • 28
    • 14544301424 scopus 로고    scopus 로고
    • The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in spo2 calculation
    • Shelley KH, Tamai D, Jablonka D, Gesquiere M, Stout RG, Silverman DG. The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in spo2 calculation. Anesth Analg 2005; 100: 743-7
    • (2005) Anesth Analg , vol.100 , pp. 743-747
    • Shelley, K.H.1    Tamai, D.2    Jablonka, D.3    Gesquiere, M.4    Stout, R.G.5    Silverman, D.G.6
  • 29
    • 0343893748 scopus 로고    scopus 로고
    • The acute respiratory distress syndrome network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome
    • The acute respiratory distress syndrome network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 2000; 342: 1301-8
    • (2000) N Engl J Med , vol.342 , pp. 1301-1308
  • 30
    • 10744227652 scopus 로고    scopus 로고
    • Simplified method to measure respiratory-related changes in arterial pulse pressure in patients receiving mechanical ventilation
    • Morelot-Panzini C, Lefort Y, Derenne JP, Similowski T. Simplified method to measure respiratory-related changes in arterial pulse pressure in patients receiving mechanical ventilation. Chest 2003; 124: 665-70
    • (2003) Chest , vol.124 , pp. 665-670
    • Morelot-Panzini, C.1    Lefort, Y.2    Derenne, J.P.3    Similowski, T.4
  • 31
    • 0346732923 scopus 로고    scopus 로고
    • The respiratory change in preejection period: A new method to predict fluid responsiveness
    • Bendjelid K, Suter PM, Romand JA. The respiratory change in preejection period: A new method to predict fluid responsiveness. J Appl Physiol 2004; 96: 337-42
    • (2004) J Appl Physiol , vol.96 , pp. 337-342
    • Bendjelid, K.1    Suter, P.M.2    Romand, J.A.3
  • 32
    • 0037906107 scopus 로고    scopus 로고
    • Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function
    • Reuter DA, Kirchner A, Felbinger TW, Weis FC, Kilger E, Lamm P, Goetz AE. Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med 2003; 31: 1399-404
    • (2003) Crit Care Med , vol.31 , pp. 1399-1404
    • Reuter, D.A.1    Kirchner, A.2    Felbinger, T.W.3    Weis, F.C.4    Kilger, E.5    Lamm, P.6    Goetz, A.E.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.