메뉴 건너뛰기




Volumn 16, Issue 3, 2007, Pages 270-280

Influence of length and diameter of implants associated with distal extension removable partial dentures

Author keywords

Biomechanics; Dental implant; Finite element analysis; Removable partial denture

Indexed keywords

ARTICLE; COMPUTER AIDED DESIGN; DENTAL CARE; DENTURE; FINITE ELEMENT ANALYSIS; MANDIBLE; METHODOLOGY; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 34548552947     PISSN: 10566163     EISSN: None     Source Type: Journal    
DOI: 10.1097/ID.0b013e31805007aa     Document Type: Article
Times cited : (47)

References (38)
  • 1
    • 34548576635 scopus 로고    scopus 로고
    • Distal-extension removable partial denture associated with an osseointegrated implant. Study by the finite element method
    • Rocha EP, Luersen MA, Pellizzer EP, et al. Distal-extension removable partial denture associated with an osseointegrated implant. Study by the finite element method. J Dent Res. 2003;82:B-254.
    • (2003) J Dent Res , vol.82
    • Rocha, E.P.1    Luersen, M.A.2    Pellizzer, E.P.3
  • 2
    • 0026214332 scopus 로고
    • Stereophotogrammetric analysis of abutment tooth movement In distal-extension removable partial dentures with intracoronal attachments and clasps
    • Chou TM, Eick JD, Moore JD, et al. Stereophotogrammetric analysis of abutment tooth movement In distal-extension removable partial dentures with intracoronal attachments and clasps. J Prosthet Dent. 1991;66:343-349.
    • (1991) J Prosthet Dent , vol.66 , pp. 343-349
    • Chou, T.M.1    Eick, J.D.2    Moore, J.D.3
  • 3
    • 0030227647 scopus 로고    scopus 로고
    • Effect of splinting on load distribution of extracoronal attachment with distal extension prosthesis In vitro
    • el Charkawi HG, el Wakad MT. Effect of splinting on load distribution of extracoronal attachment with distal extension prosthesis In vitro. J Prosthet Dent. 1996;76:315-320.
    • (1996) J Prosthet Dent , vol.76 , pp. 315-320
    • el Charkawi, H.G.1    el Wakad, M.T.2
  • 4
    • 0032043840 scopus 로고    scopus 로고
    • Effects of periodontal support and fixed splinting on load transfer by removable partial dentures
    • Itoh H, Caputo AA, Wylie R, et al. Effects of periodontal support and fixed splinting on load transfer by removable partial dentures. J Prosthet Dent. 1998;79:465-471.
    • (1998) J Prosthet Dent , vol.79 , pp. 465-471
    • Itoh, H.1    Caputo, A.A.2    Wylie, R.3
  • 5
    • 0024678672 scopus 로고
    • Analysis of abutment tooth movement utilizing mandibular kinesiography (MKG). Part 2. Effects of clasp design in unilateral free-end denture
    • Morikawa M, Masumi S, Kido H, et al. Analysis of abutment tooth movement utilizing mandibular kinesiography (MKG). Part 2. Effects of clasp design in unilateral free-end denture. Dent Mater J. 1989;8:56-64.
    • (1989) Dent Mater J , vol.8 , pp. 56-64
    • Morikawa, M.1    Masumi, S.2    Kido, H.3
  • 6
    • 0015071631 scopus 로고
    • Impression techniques for attachment-retained distal extension removable partial dentures
    • Preiskel HW. Impression techniques for attachment-retained distal extension removable partial dentures. J Prosthet Dent. 1971;25:620-628.
    • (1971) J Prosthet Dent , vol.25 , pp. 620-628
    • Preiskel, H.W.1
  • 7
    • 0018473482 scopus 로고
    • The effect of various clasping systems on the mobility of abutment teeth for distal-extension removable partial dentures
    • Tebrock OC, Rohen RM, Fenster RK, et al. The effect of various clasping systems on the mobility of abutment teeth for distal-extension removable partial dentures. J Prosthet Dent. 1979;41:511-516.
    • (1979) J Prosthet Dent , vol.41 , pp. 511-516
    • Tebrock, O.C.1    Rohen, R.M.2    Fenster, R.K.3
  • 8
    • 0017944328 scopus 로고
    • Stresses from loading distal-extension removable partial dentures
    • Craig RG, Farah JW. Stresses from loading distal-extension removable partial dentures. J Prosthet Dent. 1978;39:274-277.
    • (1978) J Prosthet Dent , vol.39 , pp. 274-277
    • Craig, R.G.1    Farah, J.W.2
  • 9
    • 4143065971 scopus 로고    scopus 로고
    • The use of short, wide implants in posterior areas with reduced bone height: A retrospective investigation
    • Griffin TJ, Cheung WS. The use of short, wide implants in posterior areas with reduced bone height: A retrospective investigation. J Prosthet Dent. 2004;92:139-144.
    • (2004) J Prosthet Dent , vol.92 , pp. 139-144
    • Griffin, T.J.1    Cheung, W.S.2
  • 10
    • 0034202611 scopus 로고    scopus 로고
    • Distal extension mandibular removable partial denture connected to an anterior fixed implant-supported prosthesis: A clinical report
    • Pellecchia M, Pellecchla R, Emtiaz S. Distal extension mandibular removable partial denture connected to an anterior fixed implant-supported prosthesis: A clinical report. J Prosthet Dent. 2000;83:607-612.
    • (2000) J Prosthet Dent , vol.83 , pp. 607-612
    • Pellecchia, M.1    Pellecchla, R.2    Emtiaz, S.3
  • 11
    • 0035262207 scopus 로고    scopus 로고
    • The distal extension case: An alternative restorative design for Implant prosthetics
    • Starr NL. The distal extension case: An alternative restorative design for Implant prosthetics. Int J Periodontics Restorative Dent. 2001;21:61-67.
    • (2001) Int J Periodontics Restorative Dent , vol.21 , pp. 61-67
    • Starr, N.L.1
  • 12
    • 0030255713 scopus 로고    scopus 로고
    • Solving the distal extension removable partial denture base movement dilemma: A clinical report
    • Giffin KM. Solving the distal extension removable partial denture base movement dilemma: A clinical report. J Prosthet Dent. 1996;76:347-349.
    • (1996) J Prosthet Dent , vol.76 , pp. 347-349
    • Giffin, K.M.1
  • 13
    • 0027347182 scopus 로고
    • Distal extension removable partial dentures supported by implants and residual teeth: Considerations and case reports
    • Keltjens HM, Kayser AF, Hertel R, et al. Distal extension removable partial dentures supported by implants and residual teeth: Considerations and case reports. Int J Oral Maxillofac Implants. 1993;8:208-213.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 208-213
    • Keltjens, H.M.1    Kayser, A.F.2    Hertel, R.3
  • 14
    • 0031986671 scopus 로고    scopus 로고
    • Evaluating parameters of osseointegrated dental implants using finite element analysis-A two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction
    • Holmgren EP, Seckinger RJ, Kilgren LM, et al. Evaluating parameters of osseointegrated dental implants using finite element analysis-A two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantai. 1998;24:80-88.
    • (1998) J Oral Implantai , vol.24 , pp. 80-88
    • Holmgren, E.P.1    Seckinger, R.J.2    Kilgren, L.M.3
  • 15
    • 0031173884 scopus 로고    scopus 로고
    • Biomechanical advantages of wide-diameter implants
    • Jarvis WC. Biomechanical advantages of wide-diameter implants. Compend Contin Educ Dent. 1997;18:687-692.
    • (1997) Compend Contin Educ Dent , vol.18 , pp. 687-692
    • Jarvis, W.C.1
  • 16
    • 0033251508 scopus 로고    scopus 로고
    • Implant design considerations for the posterior regions of the mouth
    • Misch CE. Implant design considerations for the posterior regions of the mouth. Implant Dent. 1999;8:376-386.
    • (1999) Implant Dent , vol.8 , pp. 376-386
    • Misch, C.E.1
  • 18
    • 0033193655 scopus 로고    scopus 로고
    • Survival of the Branemark implant in partially edentulous jaws: A 10-year prospective multicenter study
    • Lekholm U, Gunne J, Henry P, et al. Survival of the Branemark implant in partially edentulous jaws: A 10-year prospective multicenter study. Int J Oral Maxillofac Implants. 1999;14:639-645.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 639-645
    • Lekholm, U.1    Gunne, J.2    Henry, P.3
  • 19
    • 85006809401 scopus 로고
    • Osseointegrated implants In the treatment of partially edentulous jaws: A prospective 5-year multicenter study
    • Lekholm U, van Steenberghe D, Herrmann I, et al. Osseointegrated implants In the treatment of partially edentulous jaws: A prospective 5-year multicenter study. Int J Oral Maxillofac Implants. 1994;9:627-635.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 627-635
    • Lekholm, U.1    van Steenberghe, D.2    Herrmann, I.3
  • 20
    • 0029449258 scopus 로고
    • Finite element analysis of stress distribution at the tooth-denture base interface of acrylic resin teeth debonding from the denture base
    • Darbar UR, Huggett R, Harrison A, et al. Finite element analysis of stress distribution at the tooth-denture base interface of acrylic resin teeth debonding from the denture base. J Prosthet Dent. 1995;74:591-594.
    • (1995) J Prosthet Dent , vol.74 , pp. 591-594
    • Darbar, U.R.1    Huggett, R.2    Harrison, A.3
  • 21
    • 0000822031 scopus 로고
    • The thickness of the human periodontal membrane
    • Coolidge ED. The thickness of the human periodontal membrane. J Am Dent Assoc. 1937;24:1260-1270.
    • (1937) J Am Dent Assoc , vol.24 , pp. 1260-1270
    • Coolidge, E.D.1
  • 22
    • 0000171086 scopus 로고
    • Dimensions and relations of the dentogingival junction In humans
    • Gargiulo AW, Wentz FM, Orban B. Dimensions and relations of the dentogingival junction In humans. J Periodontol. 1961;32:261-267.
    • (1961) J Periodontol , vol.32 , pp. 261-267
    • Gargiulo, A.W.1    Wentz, F.M.2    Orban, B.3
  • 23
    • 0024116185 scopus 로고
    • Finite element analysis of a mandibular model
    • Farah JW, Craig RG, Meroueh KA. Finite element analysis of a mandibular model. J Oral Rehabil. 1988;15:615-624.
    • (1988) J Oral Rehabil , vol.15 , pp. 615-624
    • Farah, J.W.1    Craig, R.G.2    Meroueh, K.A.3
  • 24
    • 0026923976 scopus 로고
    • Effects of posts on dentin stress distribution In pulpless teeth
    • Ko CC, Chu CS, Chung KH, et al. Effects of posts on dentin stress distribution In pulpless teeth. J Prosthet Dent. 1992;68:421-427.
    • (1992) J Prosthet Dent , vol.68 , pp. 421-427
    • Ko, C.C.1    Chu, C.S.2    Chung, K.H.3
  • 25
    • 0030208125 scopus 로고    scopus 로고
    • Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis
    • Sertgoz A, Gunever S. Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis. J Prosthet Dent. 1996;76:165-169.
    • (1996) J Prosthet Dent , vol.76 , pp. 165-169
    • Sertgoz, A.1    Gunever, S.2
  • 27
    • 0026305224 scopus 로고
    • A biomechanical rationale for the use of short implants
    • Lum LB. A biomechanical rationale for the use of short implants. J Oral Implantol. 1991;17:126-131.
    • (1991) J Oral Implantol , vol.17 , pp. 126-131
    • Lum, L.B.1
  • 28
    • 0026830306 scopus 로고
    • Management of an anterior defect with a removable partial denture supported by implants and residual teeth: A case report
    • Battistuzzi GFP, van Slooten H, Käyser AF. Management of an anterior defect with a removable partial denture supported by implants and residual teeth: A case report. Int J Oral Maxillofac Implants. 1992;7:112-115.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 112-115
    • Battistuzzi, G.F.P.1    van Slooten, H.2    Käyser, A.F.3
  • 29
    • 0036674984 scopus 로고    scopus 로고
    • Prosthodontic rehabilitation with a swing-lock removable partial denture and a single osseointegrated implant: A clinical report
    • McAndrew R. Prosthodontic rehabilitation with a swing-lock removable partial denture and a single osseointegrated implant: A clinical report. J Prosthet Dent. 2002;88:128-131.
    • (2002) J Prosthet Dent , vol.88 , pp. 128-131
    • McAndrew, R.1
  • 30
    • 0030711685 scopus 로고    scopus 로고
    • Biomechanics of oral implants: A review of the literature
    • Duyck J, Naert IE, Van Oosterwyck H, et al. Biomechanics of oral implants: A review of the literature. Technol Health Care. 1997;5:253-273.
    • (1997) Technol Health Care , vol.5 , pp. 253-273
    • Duyck, J.1    Naert, I.E.2    Van Oosterwyck, H.3
  • 31
    • 1342302781 scopus 로고    scopus 로고
    • Influence of implant length and bicortical anchorage on implant stress distribution
    • Pierrisnard L, Renouard F, Renaut P, et al. Influence of implant length and bicortical anchorage on implant stress distribution. Clin Implant Dent Relat Res. 2003;5:254-262.
    • (2003) Clin Implant Dent Relat Res , vol.5 , pp. 254-262
    • Pierrisnard, L.1    Renouard, F.2    Renaut, P.3
  • 32
    • 0036134211 scopus 로고    scopus 로고
    • Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution In the bone
    • Iplikcioglu H, Akca K. Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution In the bone. J Dent. 2002;30:41-46.
    • (2002) J Dent , vol.30 , pp. 41-46
    • Iplikcioglu, H.1    Akca, K.2
  • 33
    • 0026892027 scopus 로고
    • Stress distribution around dental implants: Influence of superstructure, length of implants, and height of mandible
    • Meijer HJ, Kuiper JH, Starmans FJ, et al. Stress distribution around dental implants: Influence of superstructure, length of implants, and height of mandible. J Prosthet Dent. 1992;68:96-102.
    • (1992) J Prosthet Dent , vol.68 , pp. 96-102
    • Meijer, H.J.1    Kuiper, J.H.2    Starmans, F.J.3
  • 34
    • 0346461396 scopus 로고    scopus 로고
    • Influence of implant length and diameter on stress distribution: A finite element analysis
    • Himmlova L, Dostalova T, Kacovsky A, et al. Influence of implant length and diameter on stress distribution: A finite element analysis. J Prosthet Dent. 2004;91:20-25.
    • (2004) J Prosthet Dent , vol.91 , pp. 20-25
    • Himmlova, L.1    Dostalova, T.2    Kacovsky, A.3
  • 35
    • 0031299758 scopus 로고    scopus 로고
    • Implant diameter and bone density: Effect on initial stability and pull-out resistance
    • Kido H, Schulz EE, Kumar A, et al. Implant diameter and bone density: Effect on initial stability and pull-out resistance. J Oral Implantol. 1997;23:163-169.
    • (1997) J Oral Implantol , vol.23 , pp. 163-169
    • Kido, H.1    Schulz, E.E.2    Kumar, A.3
  • 36
    • 0033631118 scopus 로고    scopus 로고
    • A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region
    • Sato Y, Shindoi N, Hosokawa R, et al. A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region. J Oral Rehabil. 2000;27:15-21.
    • (2000) J Oral Rehabil , vol.27 , pp. 15-21
    • Sato, Y.1    Shindoi, N.2    Hosokawa, R.3
  • 37
    • 0029420299 scopus 로고    scopus 로고
    • Murphy WM, Williams KR, Gregory MC. Stress In bone adjacent to dental implants. J Oral Rehabil. 1995;22:897-903.
    • Murphy WM, Williams KR, Gregory MC. Stress In bone adjacent to dental implants. J Oral Rehabil. 1995;22:897-903.
  • 38
    • 0035377329 scopus 로고    scopus 로고
    • Application of finite element analysis in implant dentistry: A review of the literature
    • Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: A review of the literature. J Prosthet Dent. 2001;85:585-598.
    • (2001) J Prosthet Dent , vol.85 , pp. 585-598
    • Geng, J.P.1    Tan, K.B.2    Liu, G.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.