메뉴 건너뛰기




Volumn 6, Issue 4, 2007, Pages 462-469

Prosthesis-patient mismatch with latest generation supra-annular prostheses. The beginning of the end?

Author keywords

Aortic valve replacement; Mortality; Prosthesis patient mismatch

Indexed keywords

AGED; AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; CONFERENCE PAPER; CONTROLLED STUDY; FEMALE; FOLLOW UP; HEART DEATH; HEART LEFT VENTRICLE MASS; HUMAN; MAJOR CLINICAL STUDY; MALE; MORTALITY; PRIORITY JOURNAL; PROGNOSIS; AORTA VALVE; ARTICLE; ECHOCARDIOGRAPHY; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; MIDDLE AGED; PROSTHESIS;

EID: 34548385270     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2006.145532     Document Type: Conference Paper
Times cited : (13)

References (15)
  • 3
    • 33746210044 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch is not clinically relevant in aortic valve replacement using the Carpentier-Edwards Perimount valve
    • Flameng W, Meuris B, Herijgers P, Herregods MC. Prosthesis-patient mismatch is not clinically relevant in aortic valve replacement using the Carpentier-Edwards Perimount valve. Ann Thorac Surg 2006;82:530-536.
    • (2006) Ann Thorac Surg , vol.82 , pp. 530-536
    • Flameng, W.1    Meuris, B.2    Herijgers, P.3    Herregods, M.C.4
  • 4
    • 4444324517 scopus 로고    scopus 로고
    • Small aortic annulus: The hydrodynamic performances of 5 commercially available bileaflet mechanical valves
    • Bottio T, Caprili L, Casarotto D, Gerosa G. Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves. J Thorac Cardiovasc Surg 2004;128:457-462.
    • (2004) J Thorac Cardiovasc Surg , vol.128 , pp. 457-462
    • Bottio, T.1    Caprili, L.2    Casarotto, D.3    Gerosa, G.4
  • 7
    • 0032480758 scopus 로고    scopus 로고
    • Bonow RO, Carabello B, de Leon AC Jr, Edmunds LH Jr, Fedderly BJ, Freed MD, Gaasch WH, McKay CR, Nishimura RA, O'Gara PT, O'Rourke RA, Rahimtoola SH, Ritchie JL, Cheitlin MD, Eagle KA, Gardner TJ, Garson A Jr, Gibbons RJ, Russell RO, Ryan TJ, Smith SC Jr. Guidelines for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on management of patients with valvular heart disease). Circulation 1998; 98:1949-1984.
    • Bonow RO, Carabello B, de Leon AC Jr, Edmunds LH Jr, Fedderly BJ, Freed MD, Gaasch WH, McKay CR, Nishimura RA, O'Gara PT, O'Rourke RA, Rahimtoola SH, Ritchie JL, Cheitlin MD, Eagle KA, Gardner TJ, Garson A Jr, Gibbons RJ, Russell RO, Ryan TJ, Smith SC Jr. Guidelines for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on management of patients with valvular heart disease). Circulation 1998; 98:1949-1984.
  • 8
    • 0018104133 scopus 로고
    • The problem of valve prosthesis-patient mismatch
    • Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation 1978;58:20-24.
    • (1978) Circulation , vol.58 , pp. 20-24
    • Rahimtoola, S.H.1
  • 9
    • 0032711888 scopus 로고    scopus 로고
    • Patient-prosthesis mismatch is negligible with modern small-size aortic valve prostheses
    • Izzat MB, Kadir I, Reeves B, Wilde P, Bryan AJ, Angelini GD. Patient-prosthesis mismatch is negligible with modern small-size aortic valve prostheses. Ann Thorac Surg 1999;68:1657-1660.
    • (1999) Ann Thorac Surg , vol.68 , pp. 1657-1660
    • Izzat, M.B.1    Kadir, I.2    Reeves, B.3    Wilde, P.4    Bryan, A.J.5    Angelini, G.D.6
  • 11
    • 27944474709 scopus 로고    scopus 로고
    • Carpentier-Edwards Perimount Magna bioprosthesis: A stented valve with stentless performance?
    • Totaro P, Degno N, Zaidi A, Youhana A, Argano V. Carpentier-Edwards Perimount Magna bioprosthesis: a stented valve with stentless performance? J Thorac Cardiovasc Surg 2005;130:1668-1674.
    • (2005) J Thorac Cardiovasc Surg , vol.130 , pp. 1668-1674
    • Totaro, P.1    Degno, N.2    Zaidi, A.3    Youhana, A.4    Argano, V.5
  • 14
    • 33644870470 scopus 로고    scopus 로고
    • Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude Medical mechanical prostheses in the aortic position
    • Mohty-Echahidi D, Malouf JF, Girard SE, Schaff HV, Grill DE, Enriquez-Sarano ME, Miller FA Jr. Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude Medical mechanical prostheses in the aortic position. Circulation 2006;113:420-426.
    • (2006) Circulation , vol.113 , pp. 420-426
    • Mohty-Echahidi, D.1    Malouf, J.F.2    Girard, S.E.3    Schaff, H.V.4    Grill, D.E.5    Enriquez-Sarano, M.E.6    Miller Jr., F.A.7
  • 15
    • 33745042199 scopus 로고    scopus 로고
    • Is severe valve prosthesis-patient mismatch (VP-PM) associated with a higher mortality?
    • Rahimtoola SH. Is severe valve prosthesis-patient mismatch (VP-PM) associated with a higher mortality? Eur J Cardiothorac Surg 2006;30:1.
    • (2006) Eur J Cardiothorac Surg , vol.30 , pp. 1
    • Rahimtoola, S.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.