-
1
-
-
0030921527
-
Pulmonary embolization of permanently implanted radioactive palladium-103 seeds for carcinoma of the prostate
-
Nag S, Vivekanandam S, Martinez-Monge R. Pulmonary embolization of permanently implanted radioactive palladium-103 seeds for carcinoma of the prostate. Int J Radiat Oncol Biol Phys. 1997;39(3):667-670.
-
(1997)
Int J Radiat Oncol Biol Phys
, vol.39
, Issue.3
, pp. 667-670
-
-
Nag, S.1
Vivekanandam, S.2
Martinez-Monge, R.3
-
2
-
-
0032437496
-
Reduction of radioactive seed embolization to the lung following prostate brachytherapy
-
Tapen EM, Blasko JC, Grimm PD, et al. Reduction of radioactive seed embolization to the lung following prostate brachytherapy. Ent J Radiat Oncol Biol Phys. 1998;42(5):1063-1067.
-
(1998)
Ent J Radiat Oncol Biol Phys
, vol.42
, Issue.5
, pp. 1063-1067
-
-
Tapen, E.M.1
Blasko, J.C.2
Grimm, P.D.3
-
3
-
-
2442453690
-
The use of linked seeds eliminates lung embolization following permanent seed implantation for prostate cancer
-
Al-Qaisieh B, Carey B, Ash D, Bottomley D. The use of linked seeds eliminates lung embolization following permanent seed implantation for prostate cancer. Int J Radiat Oncol Biol Phys. 2004;59(2):397-399.
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, Issue.2
, pp. 397-399
-
-
Al-Qaisieh, B.1
Carey, B.2
Ash, D.3
Bottomley, D.4
-
4
-
-
4544264985
-
Migration of implanted free radioactive seeds for adenocarcinoma of the prostate using a Mick applicator
-
Kunos CA, Resnick MI, Kinsella TJ, Ellis RJ. Migration of implanted free radioactive seeds for adenocarcinoma of the prostate using a Mick applicator. Brachytherapy. 2004;3(2):71-77.
-
(2004)
Brachytherapy
, vol.3
, Issue.2
, pp. 71-77
-
-
Kunos, C.A.1
Resnick, M.I.2
Kinsella, T.J.3
Ellis, R.J.4
-
5
-
-
0035047010
-
Radioactive implant migration in patients treated for localized prostate cancer with interstitial brachytherapy
-
Older RA, Synder B, Krupski TL, Glembocki DJ, Gillenwater JY. Radioactive implant migration in patients treated for localized prostate cancer with interstitial brachytherapy. J Urol. 2001; 165(5):1590-1592.
-
(2001)
J Urol
, vol.165
, Issue.5
, pp. 1590-1592
-
-
Older, R.A.1
Synder, B.2
Krupski, T.L.3
Glembocki, D.J.4
Gillenwater, J.Y.5
-
6
-
-
0028030133
-
Dose effects of seeds placement deviations from pre-planned positions in ultrasound guided prostate implants
-
Dawson JE, Wu T, Roy T, Gu JY, Kim H. Dose effects of seeds placement deviations from pre-planned positions in ultrasound guided prostate implants. Radiother Oncol. 1994;32(3):268-270.
-
(1994)
Radiother Oncol
, vol.32
, Issue.3
, pp. 268-270
-
-
Dawson, J.E.1
Wu, T.2
Roy, T.3
Gu, J.Y.4
Kim, H.5
-
9
-
-
85024368571
-
First report on the clinical use of palladium- 103 coils: Safety and efficacy in the brachytherapy treatment of early stage prostate cancer [Abstract]
-
Hartford AC, Gladstone DJ, Seigne JD, Marshall JF, Rogers CC, Hug EB. First report on the clinical use of palladium- 103 coils: safety and efficacy in the brachytherapy treatment of early stage prostate cancer [Abstract]. Int J Radiat Oncol Biol Phys. 2005;63(2 Suppl 1):S319-S320.
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.63
, Issue.2 SUPPL. 1
-
-
Hartford, A.C.1
Gladstone, D.J.2
Seigne, J.D.3
Marshall, J.F.4
Rogers, C.C.5
Hug, E.B.6
-
10
-
-
1142304255
-
Update of AAPM Task Group No. 43 report: A revised AAPM protocol for brachytherapy dose calculations
-
Rivard MJ, Coursey BM, DeWerd LA, et al. Update of AAPM Task Group No. 43 report: a revised AAPM protocol for brachytherapy dose calculations. Med Phys. 2004;31(3):633-674.
-
(2004)
Med Phys
, vol.31
, Issue.3
, pp. 633-674
-
-
Rivard, M.J.1
Coursey, B.M.2
DeWerd, L.A.3
-
12
-
-
33750557451
-
Evaluation of TG-43U1 recommended 2D-anisotropy function for elongated brachytherapy sources
-
Awan SB, Meigooni AS, Mokhberiosgouei R, Hussain M. Evaluation of TG-43U1 recommended 2D-anisotropy function for elongated brachytherapy sources. Med Phys. 2006;33(11):4271-4279.
-
(2006)
Med Phys
, vol.33
, Issue.11
, pp. 4271-4279
-
-
Awan, S.B.1
Meigooni, A.S.2
Mokhberiosgouei, R.3
Hussain, M.4
-
13
-
-
33750546257
-
Feasibility of calibrating elongated brachytherapy sources using a well-type ionization chamber
-
Meigooni AS, Awan SB, Dou K. Feasibility of calibrating elongated brachytherapy sources using a well-type ionization chamber. Med Phys. 2006;33(11):4184-4189.
-
(2006)
Med Phys
, vol.33
, Issue.11
, pp. 4184-4189
-
-
Meigooni, A.S.1
Awan, S.B.2
Dou, K.3
-
14
-
-
0033625386
-
Dosimetric characteristics of the InterSource103 palladium brachytherapy source
-
Meigooni AS, Sowards K, Soldano M. Dosimetric characteristics of the InterSource103 palladium brachytherapy source. Med Phys. 2000;27(5):1093-1100.
-
(2000)
Med Phys
, vol.27
, Issue.5
, pp. 1093-1100
-
-
Meigooni, A.S.1
Sowards, K.2
Soldano, M.3
-
18
-
-
4544308285
-
125P brachytherapy sources
-
Isot
-
125P brachytherapy sources. Appl Radiat Isot. 2004; 61(6):1443-1450.
-
(2004)
Appl Radiat
, vol.61
, Issue.6
, pp. 1443-1450
-
-
Duggan, D.M.1
-
19
-
-
0003395844
-
MCNP - a general Monte Carlo N-particle transport code. Ver.5
-
X-5 Monte Carlo Team, BNL-NCS-17541. 8th edition. Los Alamos NM, Los Alamos National Laboratory;
-
X-5 Monte Carlo Team. MCNP - a general Monte Carlo N-particle transport code. Ver.5. Los Alamos National Laboratory Report BNL-NCS-17541. 8th edition. Los Alamos (NM): Los Alamos National Laboratory; 2000.
-
(2000)
Los Alamos National Laboratory Report
-
-
-
20
-
-
0003734977
-
ENDF/B-VI Summary Documentation. ENDF-201
-
Cross Section Evaluation Worldng Group, BNL-NCS-17541. 8th edition. Upton NY, National Nuclear Data Center;
-
Cross Section Evaluation Worldng Group. ENDF/B-VI Summary Documentation. ENDF-201. Brookhaven National Laboratory Report BNL-NCS-17541. 8th edition. Upton (NY): National Nuclear Data Center; 2000.
-
(2000)
Brookhaven National Laboratory Report
-
-
-
21
-
-
85024396316
-
-
Hubbell JH, Seltzer SM. Tables of X-ray mass attenuation coefficients and mass energy absorption coefficients [Web resource, Ver. 1.4. Gaithersburg (MD, National Institute of Standards and Technology; 1996 update: 2004, Available at: /xaamdi; cited 10January 2006
-
Hubbell JH, Seltzer SM. Tables of X-ray mass attenuation coefficients and mass energy absorption coefficients [Web resource]. Ver. 1.4. Gaithersburg (MD): National Institute of Standards and Technology; 1996 (update: 2004). [Available at: physics.nist.gov/xaamdi; cited 10January 2006]
-
-
-
-
23
-
-
0034004934
-
103Pd interstitial brachytherapy source
-
103Pd interstitial brachytherapy source. Med Phys. 2000;27(4):643-654.
-
(2000)
Med Phys
, vol.27
, Issue.4
, pp. 643-654
-
-
Monte, W.J.F.1
-
24
-
-
0032217054
-
103Pd sources
-
103Pd sources. Med Phys. 1998;25(12):2271-2278.
-
(1998)
Med Phys
, vol.25
, Issue.12
, pp. 2271-2278
-
-
Weaver, K.1
|