Evaluation of TG-43 recommended 2D-anisotropy function for elongated brachytherapy sources

Author keywords

Dosimetry; Elongated brachytherapy source; Extrapolation; Interpolation; TG 43U1

Indexed keywords

ANISOTROPY; DOSIMETRY; EXTRAPOLATION; INTERPOLATION; MONTE CARLO METHODS; ONCOLOGY;

EID: 33750557451     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2357024     Document Type: Article
Times cited : (6)

References (13)
  • 2
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. American Association of Physicists in Medicine
    • R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. American Association of Physicists in Medicine., " Med. Phys. 22, 209-234 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 3
    • 0036732646 scopus 로고    scopus 로고
    • Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE 125I brachytherapy source
    • A. S. Meigooni, J. L. Hayes, H. Zhang, and K. Sowards, " Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE 125I brachytherapy source., " Med. Phys. 29, 2152-2158 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2152-2158
    • Meigooni, A.S.1    Hayes, J.L.2    Zhang, H.3    Sowards, K.4
  • 4
    • 0036124013 scopus 로고    scopus 로고
    • Monte Carlo-aided dosimetry of the theragenics TheraSeed model 200 Pd103 interstitial brachytherapy seed
    • J. I. Monroe and J. F. Williamson, " Monte Carlo-aided dosimetry of the theragenics TheraSeed model 200 Pd103 interstitial brachytherapy seed., " Med. Phys. 29, 609-621 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 609-621
    • Monroe, J.I.1    Williamson, J.F.2
  • 5
    • 0035543812 scopus 로고    scopus 로고
    • Dosimetric characteristics of the bests double-wall Pd103 brachytherapy source
    • A. S. Meigooni, Z. Bharucha, M. Yoe-Sein, and K. Sowards, " Dosimetric characteristics of the bests double-wall Pd103 brachytherapy source., " Med. Phys. 28, 2568-2575 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2568-2575
    • Meigooni, A.S.1    Bharucha, Z.2    Yoe-Sein, M.3    Sowards, K.4
  • 6
    • 0033625386 scopus 로고    scopus 로고
    • Dosimetric characteristics of the InterSource103 palladium brachytherapy source
    • A. S. Meigooni, K. Sowards, and M. Soldano, " Dosimetric characteristics of the InterSource103 palladium brachytherapy source., " Med. Phys. 27, 1093-1100 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1093-1100
    • Meigooni, A.S.1    Sowards, K.2    Soldano, M.3
  • 7
    • 0036797392 scopus 로고    scopus 로고
    • Experimental determination of dosimetric characterization of a newly designed encapsulated interstitial brachytherapy source of Pd103 -model Pd-1
    • R. Nath, N. Yue, and E. Roa, " Experimental determination of dosimetric characterization of a newly designed encapsulated interstitial brachytherapy source of Pd103 -model Pd-1., " Med. Phys. 29, 2433-2434 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2433-2434
    • Nath, R.1    Yue, N.2    Roa, E.3
  • 8
    • 0032738001 scopus 로고    scopus 로고
    • Dosimetric characterization of a new design 103 palladium brachytherapy source
    • R. E. Wallace and J. J. Fan, " Dosimetric characterization of a new design 103 palladium brachytherapy source., " Med. Phys. 26, 2465-2470 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2465-2470
    • Wallace, R.E.1    Fan, J.J.2
  • 9
    • 9244261598 scopus 로고    scopus 로고
    • Dosimetric characteristics of the new RadioCoil™ Pd103 wire line source for use in permanent brachytherapy implants
    • A. S. Meigooni, H. Zhang, J. R. Clark, V. Rachabatthula, and R. A. Koona, " Dosimetric characteristics of the new RadioCoil™ Pd103 wire line source for use in permanent brachytherapy implants., " Med. Phys. 31, 3095-3105 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 3095-3105
    • Meigooni, A.S.1    Zhang, H.2    Clark, J.R.3    Rachabatthula, V.4    Koona, R.A.5
  • 10
    • 4544341067 scopus 로고    scopus 로고
    • X-5 Monte Carlo Team BNL-NCS-17541, 8th ed., National Nuclear Data Center
    • X-5 Monte Carlo Team, " MCNP-A general Monte Carlo N-Particle transport code, version 5., " Los Alamos National Laboratory Report BNL-NCS-17541, 8th ed., National Nuclear Data Center (December 2000).
    • (2000) MCNP-A General Monte Carlo N-Particle Transport Code, Version 5
  • 11
    • 17844378254 scopus 로고    scopus 로고
    • Cross Section Evaluation Working Group BNL-NCS-17541, 8th ed., National Nuclear Data Center (December 2000).
    • Cross Section Evaluation Working Group, " ENDF/B-VI summary documentation (ENDF-201)., " Brookhaven National Laboratory Report BNL-NCS-17541, 8th ed., National Nuclear Data Center (December 2000).
    • ENDF/B-VI Summary Documentation (ENDF-201)
  • 13
    • 19544375059 scopus 로고    scopus 로고
    • Dose verification with Monte Carlo technique for prostate brachytherapy implants with I125 sources
    • H. Zhang, C. Baker, R. Mc Kinsey, A. S. Meigooni, " Dose verification with Monte Carlo technique for prostate brachytherapy implants with I125 sources., " Med. Dosim 30, 85-91 (2005).
    • (2005) Med. Dosim , vol.30 , pp. 85-91
    • Zhang, H.1    Baker, C.2    Mc Kinsey, R.3    Meigooni, A.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.