Improved radial dose function estimation using current version MCNP Monte-Carlo simulation: Model 6711 and ISC3500 125I brachytherapy sources

Author keywords

Brachytherapy; Iodine 125; Monte Carlo simulation; Prostate cancer; Radiation dosimetry

Indexed keywords

DOSIMETERS; ISOTOPES; MONTE CARLO METHODS; PHOTONS; RADIAL BASIS FUNCTION NETWORKS; THERMOLUMINESCENCE;

EID: 4544308285     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2004.05.070     Document Type: Article
Times cited : (21)

References (25)
  • 1
    • 0037391530 scopus 로고    scopus 로고
    • Brachytherapy dosimetry of 125I and 103Pd sources using an updated cross section library for the MCNP Monte Carlo transport code
    • Bohm T.D., Deluca P.M. Jr., Dewerd L.A. Brachytherapy dosimetry of 125I and 103Pd sources using an updated cross section library for the MCNP Monte Carlo transport code. Med. Phys. 30:2003;701-711
    • (2003) Med. Phys. , vol.30 , pp. 701-711
    • Bohm, T.D.1    Deluca Jr., P.M.2    Dewerd, L.A.3
  • 4
    • 0037149981 scopus 로고    scopus 로고
    • An analysis of MCNP cross-sections and tally methods for low-energy photon emitters
    • Demarco J.J., Wallace R.E., Boedeker K. An analysis of MCNP cross-sections and tally methods for low-energy photon emitters. Phys. Med. Biol. 47:2002;1321-1332
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1321-1332
    • Demarco, J.J.1    Wallace, R.E.2    Boedeker, K.3
  • 5
    • 0035045005 scopus 로고    scopus 로고
    • Dosimetry of the I-Plant Model 3500 iodine-125 brachytherapy source
    • Duggan D.M., Johnson B.L. Dosimetry of the I-Plant Model 3500 iodine-125 brachytherapy source. Med. Phys. 28:2001;661-670
    • (2001) Med. Phys. , vol.28 , pp. 661-670
    • Duggan, D.M.1    Johnson, B.L.2
  • 7
    • 0032936813 scopus 로고    scopus 로고
    • Functional fitting of interstitial brachytherapy dosimetry data recommended by the AAPM Radiation Therapy Committee Task Group 43. American Association of Physicists in Medicine
    • Furhang E.E., Anderson L.L. Functional fitting of interstitial brachytherapy dosimetry data recommended by the AAPM Radiation Therapy Committee Task Group 43. American Association of Physicists in Medicine. Med. Phys. 26:1999;153-160
    • (1999) Med. Phys. , vol.26 , pp. 153-160
    • Furhang, E.E.1    Anderson, L.L.2
  • 8
    • 0032918665 scopus 로고    scopus 로고
    • Review of photon interaction cross section data in the medical and biological context
    • Hubbell J.H. Review of photon interaction cross section data in the medical and biological context. Phys. Med. Biol. 44:1999;R1-R22
    • (1999) Phys. Med. Biol. , vol.44
    • Hubbell, J.H.1
  • 12
    • 0028235964 scopus 로고
    • Comparison of radiation dosimetry in water and in solid phantom materials for I-125 and Pd-103 brachytherapy sources: EGS4 Monte Carlo study
    • Luxton G. Comparison of radiation dosimetry in water and in solid phantom materials for I-125 and Pd-103 brachytherapy sources. EGS4 Monte Carlo study Med. Phys. 21:1994;631-641
    • (1994) Med. Phys. , vol.21 , pp. 631-641
    • Luxton, G.1
  • 13
    • 0033461145 scopus 로고    scopus 로고
    • Radial dose distribution, dose to water and dose rate constant for monoenergetic photon point sources from 10 keV to 2 MeV: EGS4 Monte Carlo model calculation
    • Luxton G., Jozsef G. Radial dose distribution, dose to water and dose rate constant for monoenergetic photon point sources from 10. keV to 2 MeV EGS4 Monte Carlo model calculation Med. Phys. 26:1999;2531-2538
    • (1999) Med. Phys. , vol.26 , pp. 2531-2538
    • Luxton, G.1    Jozsef, G.2
  • 15
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. American Association of Physicists in Medicine
    • Nath R., Anderson L.L., Luxton G., Weaver K.A., Williamson J.F., Meigooni A.S. Dosimetry of interstitial brachytherapy sources. recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. American Association of Physicists in Medicine Med. Phys. 22:1995;209-234
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 16
    • 4544262221 scopus 로고    scopus 로고
    • Brookhaven National Laboratory, Brookhaven, NY, USA.
    • National Nuclear Data Center, 2003. Nuclear Data (NuDat) Retreival Program, Vol. 2003. Brookhaven National Laboratory, Brookhaven, NY, USA.
    • (2003) Nuclear Data (NuDat) Retreival Program , vol.2003
  • 17
    • 0036318674 scopus 로고    scopus 로고
    • Comprehensive Monte Carlo calculations of AAPM Task Group Report No. 43 dosimetry parameters for the Model 3500 I-Plant 125I brachytherapy source
    • Rivard M.J. Comprehensive Monte Carlo calculations of AAPM Task Group Report No. 43 dosimetry parameters for the Model 3500 I-Plant 125I brachytherapy source. Appl. Radiat. Isot. 57:2002;381-389
    • (2002) Appl. Radiat. Isot. , vol.57 , pp. 381-389
    • Rivard, M.J.1
  • 21
    • 0036007537 scopus 로고    scopus 로고
    • Model 3500 125I brachytherapy source dosimetric characterization
    • Wallace R.E. Model 3500 125I brachytherapy source dosimetric characterization. Appl. Radiat. Isot. 56:2002;581-587
    • (2002) Appl. Radiat. Isot. , vol.56 , pp. 581-587
    • Wallace, R.E.1
  • 22
    • 0025900734 scopus 로고
    • Comparison of measured and calculated dose rates in water near I-125 and Ir-192 seeds
    • Williamson J.F. Comparison of measured and calculated dose rates in water near I-125 and Ir-192 seeds. Med. Phys. 18:1991;776-786
    • (1991) Med. Phys. , vol.18 , pp. 776-786
    • Williamson, J.F.1
  • 23
    • 0036118006 scopus 로고    scopus 로고
    • Dosimetric characteristics of the DRAXIMAGE model LS-1 1-125 interstitial brachytherapy source design: A Monte Carlo investigation
    • Williamson J.F. Dosimetric characteristics of the DRAXIMAGE model LS-1 1-125 interstitial brachytherapy source design. a Monte Carlo investigation Med. Phys. 29:2002;509-521
    • (2002) Med. Phys. , vol.29 , pp. 509-521
    • Williamson, J.F.1
  • 24
    • 0032427802 scopus 로고    scopus 로고
    • Dosimetric prerequisites for routine clinical use of new low energy photon interstitial brachytherapy sources. Recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee. Ad Hoc Subcommittee of the Radiation Therapy Committee
    • Williamson J., Coursey B.M., DeWerd L.A., Hanson W.F., Nath R. Dosimetric prerequisites for routine clinical use of new low energy photon interstitial brachytherapy sources. Recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee. Ad Hoc Subcommittee of the Radiation Therapy Committee. Med. Phys. 25:1998;2269-2270
    • (1998) Med. Phys. , vol.25 , pp. 2269-2270
    • Williamson, J.1    Coursey, B.M.2    Dewerd, L.A.3    Hanson, W.F.4    Nath, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.