메뉴 건너뛰기




Volumn 579, Issue 1, 2007, Pages 380-383

Gamma radiation detectors for safeguards applications

Author keywords

CZT; Gamma detectors; HpGe; NaI; Safeguards

Indexed keywords

GAMMA RAYS; IMAGING SYSTEMS; ROBUSTNESS (CONTROL SYSTEMS); SAFETY ENGINEERING; SPECTROMETRY;

EID: 34547693390     PISSN: 01689002     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nima.2007.04.086     Document Type: Article
Times cited : (37)

References (16)
  • 1
    • 34547710514 scopus 로고    scopus 로고
    • International Atomic Energy Agency, Safeguards Techniques and Equipment, International Nuclear Verification Series No. 1 (Revised), August 2003.
  • 2
    • 34547722046 scopus 로고    scopus 로고
    • R. Gunnink, A new one-detector analysis method for rapid high-precision plutonium isotopic measurements, in: Proceedings of the ninth ESARDA Symposium on Safeguards and Nuclear Material Management, London, UK, May 12-14, 1987, pp. 167-171.
  • 3
    • 34547694833 scopus 로고    scopus 로고
    • R. Gunnink, W. Ruhter, P. Miller, J. Goerten, M. Swinhoe, H. Wagner, J. Verplancke, M. Bickel, S. Abousahl, MGAU: a new analysis code for measuring U-235 enrichments in arbitrary samples. Presented at the IAEA Symposium on International Safeguards, Vienna, Austria, March 8-14, 1994.
  • 4
    • 34547712075 scopus 로고    scopus 로고
    • Model 1300, Inspector 2000, "Hardware Manual", 9231618D, Canberra Industries, 800 Research Parkway, CT-06450 Meriden, USA, 2000.
  • 5
    • 34547705101 scopus 로고    scopus 로고
    • R. Keyser, T. Twomey, D. Upp, Performance of light weight, battery operated, high purity germanium detector for field use, in: Proceedings of 44th INNM Conference, Phoenix, July 2003.
  • 6
    • 34547707412 scopus 로고    scopus 로고
    • 〈www.canberra.com/pdf/Products/Detectors_pdf/CryoCycle%20Cryostat%20super%20spec.pdf〉.
  • 7
    • 34547716590 scopus 로고    scopus 로고
    • M. Swoboda, H. Böck, Comparison of CZT Detectors for Use in Hand Held Isotope Identifiers, Atominstitut der Österreichischen Universtäten, March 2002.
  • 8
    • 23844527156 scopus 로고    scopus 로고
    • G. Montemont, C. Moulin, J. Isard, L. Verger, A digital pulse processing dedicated to CdZnTe detectors, in: IEEE Nuclear Science Symposium, Rome, October 16-22, 2004.
  • 9
    • 11944254531 scopus 로고    scopus 로고
    • L. Verger, P. Ouvrier-Buffet, F. Mathy, G. Montemont, M. Picone, J. Rustique, C. Riffard, Performance of a new CdZnTe portable spectrometric system for high energy applications, in: IEEE Nuclear Science Symposium, Portland, 2003.
  • 10
    • 23844490470 scopus 로고    scopus 로고
    • G. Pausch, J. Stein, N. Teofilov, Stabilizing scintillation detector systems: determination of the scintillation temperature exploiting the temperature dependence of the light pulse decay time, in: IEEE Nuclear Science Symposium, Rome, October 16-22, 2004.
  • 11
    • 34547721314 scopus 로고    scopus 로고
    • M. Rahman, Performance of the PNPI CdTe Detector and its implementation for the isotopic measurements of plutonium employing the FRAM4.2 software, 2002.
  • 12
    • 34547715181 scopus 로고    scopus 로고
    • A. Khusainov, et al., Progress report on technical contract with IAEA No. 9984/RO: Development of High Performance PIN CdTe Detectors, 2000.
  • 15
    • 34547705857 scopus 로고    scopus 로고
    • M. Bliss, R.A. Craig, D.S. Barnett, D.S. Barnett, D.N. Anderson, Performance of a moderating neutron spectrometer that uses scintillating fibers, in: INMM Summer Meeting, 2001.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.