메뉴 건너뛰기




Volumn 5, Issue , 2003, Pages 3569-3573

Performance of a new CdZnTe portable spectrometric system for high energy applications

Author keywords

ray detectors; Bi Parametric correction; Capacitive grid frish; Charge sensitive preamplifier; Count rate; CZT; Energy resolution

Indexed keywords

ALGORITHMS; AMPLIFIERS (ELECTRONIC); COMPUTER SIMULATION; GERMANIUM; HIGH ENERGY PHYSICS; SENSITIVITY ANALYSIS; SPECTROMETRY; SPURIOUS SIGNAL NOISE;

EID: 11944254531     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (4)

References (13)
  • 2
    • 0041424891 scopus 로고    scopus 로고
    • Experimental comparison of discrete and CMOS charge sensitive preamplifiers for CZT radiation detectors
    • Aug.
    • G. Montemont, J.P. Rostaing, "Experimental comparison of discrete and CMOS charge sensitive preamplifiers for CZT radiation detectors", IEEE Transactions on Nuclear Science, vol. 50(1), pp. 936-941, Aug. 2003.
    • (2003) IEEE Transactions on Nuclear Science , vol.50 , Issue.1 , pp. 936-941
    • Montemont, G.1    Rostaing, J.P.2
  • 6
    • 0032114882 scopus 로고    scopus 로고
    • Coplanar grid patterns and their effect on energy resolution of CdZnTe detectors
    • Z. He, G.F. Knoll, D.K. Wehe and Y.F. Du., "Coplanar grid patterns and their effect on energy resolution of CdZnTe detectors", Nucl. Instr. Meth., vol. A411, pp. 107-113, 1998.
    • (1998) Nucl. Instr. Meth. , vol.A411 , pp. 107-113
    • He, Z.1    Knoll, G.F.2    Wehe, D.K.3    Du, Y.F.4
  • 7
    • 0032685817 scopus 로고    scopus 로고
    • Optimum spectroscopic performance from CZT y and X-ray detectors with pad and strip segmentation
    • A. Shor, Y. Eisen and L Mardor, "Optimum spectroscopic performance from CZT y and X-ray detectors with pad and strip segmentation", Nucl. Instr. Meth., vol. A428, pp. 182-192, 1999, G. De Geronimo, P. O'Connor, V. Radeka and B. Yu, "Front-end electronics for imaging detectors," Nuclear Instruments and Methods, vol. A471, pp. 192-199, 2001.
    • (1999) Nucl. Instr. Meth. , vol.A428 , pp. 182-192
    • Shor, A.1    Eisen, Y.2    Mardor, L.3
  • 8
    • 0001716704 scopus 로고    scopus 로고
    • Front-end electronics for imaging detectors
    • A. Shor, Y. Eisen and L Mardor, "Optimum spectroscopic performance from CZT y and X-ray detectors with pad and strip segmentation", Nucl. Instr. Meth., vol. A428, pp. 182-192, 1999, G. De Geronimo, P. O'Connor, V. Radeka and B. Yu, "Front-end electronics for imaging detectors," Nuclear Instruments and Methods, vol. A471, pp. 192-199, 2001.
    • (2001) Nuclear Instruments and Methods , vol.A471 , pp. 192-199
    • De Geronimo, G.1    O'Connor, P.2    Radeka, V.3    Yu, B.4
  • 9
    • 0030259462 scopus 로고    scopus 로고
    • Electrode configuration and energy resolution in gamma-ray detectors
    • P.N. Luke, "Electrode configuration and energy resolution in gamma-ray detectors", Nucl. Instr. Metfi, vol. A380, pp. 232-237, 1996.
    • (1996) Nucl. Instr. Metfi , vol.A380 , pp. 232-237
    • Luke, P.N.1
  • 11
    • 0000164906 scopus 로고    scopus 로고
    • New developements in CdTe and CdZnTe detectors for X- and gamma-ray applications
    • L. Verger, J.P. Bonnefoy, F. Classer, P. Ouvrier Buffet, " New developements in CdTe and CdZnTe Detectors for X- and Gamma-ray Applications ", Journal of Electronics Materials. Vol. 26, No. 6, pp.738-743, 1997
    • (1997) Journal of Electronics Materials , vol.26 , Issue.6 , pp. 738-743
    • Verger, L.1    Bonnefoy, J.P.2    Classer, F.3    Buffet, P.O.4
  • 12
    • 0037845017 scopus 로고    scopus 로고
    • A three dimensional of cdZnTe gamma-ray spectrometer
    • M. Picone, A Gliere, P. Masse, "A three dimensional of cdZnTe gamma-ray spectrometer", Nuclear Instruments and Methods, vol. A504, pp. 313-316, 2003.
    • (2003) Nuclear Instruments and Methods , vol.A504 , pp. 313-316
    • Picone, M.1    Gliere, A.2    Masse, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.