메뉴 건너뛰기




Volumn 34, Issue 8, 2007, Pages 3135-3142

Magnetically-assisted remote control (MARC) steering of endovascular catheters for interventional MRI: A model for deflection and design implications

Author keywords

Catheter; Interventional MRI; MRI; Steering; Vascular imaging

Indexed keywords

DEFLECTION (STRUCTURES); ELASTIC MODULI; MAGNETIC RESONANCE IMAGING; MAGNETISM; REMOTE CONTROL; SCANNING; SOLENOIDS; STEERING; TENSILE TESTING;

EID: 34547408460     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2750963     Document Type: Article
Times cited : (55)

References (27)
  • 1
    • 0035795969 scopus 로고    scopus 로고
    • Endovascular versus surgical treatment in patients with carotid stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): A randomised trial
    • CAVATAS Investigators, "
    • CAVATAS Investigators, " Endovascular versus surgical treatment in patients with carotid stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): A randomised trial., " Lancet 357, 1729-1737 (2001).
    • (2001) Lancet , vol.357 , pp. 1729-1737
  • 2
    • 0037835661 scopus 로고    scopus 로고
    • Abdominal myomectomy versus uterine fibroid embolization in the treatment of symptomatic uterine leiomyomas
    • M. K. Razavi, G. Hwang, A. Jahed, S. Modanloo, and B. Chen, " Abdominal myomectomy versus uterine fibroid embolization in the treatment of symptomatic uterine leiomyomas., " AJR, Am. J. Roentgenol. 180, 1571-1575 (2003).
    • (2003) AJR, Am. J. Roentgenol. , vol.180 , pp. 1571-1575
    • Razavi, M.K.1    Hwang, G.2    Jahed, A.3    Modanloo, S.4    Chen, B.5
  • 3
    • 26944466840 scopus 로고    scopus 로고
    • International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: A randomized comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion
    • A. J. Molyneux, R. S. Kerr, L. M. Yu, M. Clarke, M. Sneade, J. A. Yarnold, and P. Sandercock, " International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: A randomized comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion., " Lancet 366, 809-817 (2005).
    • (2005) Lancet , vol.366 , pp. 809-817
    • Molyneux, A.J.1    Kerr, R.S.2    Yu, L.M.3    Clarke, M.4    Sneade, M.5    Yarnold, J.A.6    Sandercock, P.7
  • 4
    • 0037394555 scopus 로고    scopus 로고
    • A meta-analysis of randomized controlled trials comparing coronary artery bypass graft with percutaneous transluminal coronary angioplasty: One- to eight-year outcomes
    • S. N. Hoffman, J. A. TenBrook, M. P. Wolf, S. G. Pauker, D. N. Salem, and J. B. Wong, " A meta-analysis of randomized controlled trials comparing coronary artery bypass graft with percutaneous transluminal coronary angioplasty: one- to eight-year outcomes., " J. Am. Coll. Cardiol. 41, 1293-1304 (2003).
    • (2003) J. Am. Coll. Cardiol. , vol.41 , pp. 1293-1304
    • Hoffman, S.N.1    Tenbrook, J.A.2    Wolf, M.P.3    Pauker, S.G.4    Salem, D.N.5    Wong, J.B.6
  • 5
    • 0026665992 scopus 로고
    • Inferior vena cava filters. Indications, safety, effectiveness
    • D. M. Becker, J. T. Philbrick, and J. B. Selby, " Inferior vena cava filters. Indications, safety, effectiveness., " Arch. Intern Med. 152, 1985-1994 (1992).
    • (1992) Arch. Intern Med. , vol.152 , pp. 1985-1994
    • Becker, D.M.1    Philbrick, J.T.2    Selby, J.B.3
  • 6
    • 0031966438 scopus 로고    scopus 로고
    • The first decade of the transjugular intrahepatic portosystemic shunt (TIPS): State of the art
    • M. Rossle, V. Siegerstetter, M. Huber, and A. Ochs, " The first decade of the transjugular intrahepatic portosystemic shunt (TIPS): State of the art., " Liver (Oxford, U. K.) 18, 73-89 (1998).
    • (1998) Liver (Oxford, U. K.) , vol.18 , pp. 73-89
    • Rossle, M.1    Siegerstetter, V.2    Huber, M.3    Ochs, A.4
  • 7
    • 1542345612 scopus 로고    scopus 로고
    • Endovascular treatment of cerebrovascular diseases and intracranial neoplasms
    • A. I. Qureshi, " Endovascular treatment of cerebrovascular diseases and intracranial neoplasms., " Lancet 363, 804-813 (2004).
    • (2004) Lancet , vol.363 , pp. 804-813
    • Qureshi, A.I.1
  • 8
    • 0032727132 scopus 로고    scopus 로고
    • Interventional neuroradiology in the treatment of brain tumors
    • P. Morris, " Interventional neuroradiology in the treatment of brain tumors., " Neuroimaging Clin. N. Am. 9, 767-778 (1999).
    • (1999) Neuroimaging Clin. N. Am. , vol.9 , pp. 767-778
    • Morris, P.1
  • 9
    • 2442713397 scopus 로고
    • Catheter replacement of the needle in percutaneous arteriography; A new technique
    • S. I. Seldinger, " Catheter replacement of the needle in percutaneous arteriography; a new technique., " Acta Radiol. (1921-1962) 39, 368-376 (1953).
    • (1953) Acta Radiol. (1921-1962) , vol.39 , pp. 368-376
    • Seldinger, S.I.1
  • 10
    • 0030983321 scopus 로고    scopus 로고
    • Adverse events with radiographic contrast agents: Results of the SCVIR Contrast Agent Registry
    • M. A. Bettmann, T. Heeren, A. Greenfield, and C. Goudey, " Adverse events with radiographic contrast agents: Results of the SCVIR Contrast Agent Registry., " Radiology 203, 611-620 (1997).
    • (1997) Radiology , vol.203 , pp. 611-620
    • Bettmann, M.A.1    Heeren, T.2    Greenfield, A.3    Goudey, C.4
  • 11
    • 0242487827 scopus 로고    scopus 로고
    • New magnetic resonance contrast agents as biochemical reporters
    • T. J. Meade, A. K. Taylor, and S. R. Bull, " New magnetic resonance contrast agents as biochemical reporters., " Curr. Opin. Neurobiol. 13, 597-602 (2003).
    • (2003) Curr. Opin. Neurobiol. , vol.13 , pp. 597-602
    • Meade, T.J.1    Taylor, A.K.2    Bull, S.R.3
  • 13
    • 0036077917 scopus 로고    scopus 로고
    • Mechanistic studies of a calcium-dependent MRI contrast agent
    • W. H. Li, G. Parigi, M. Fragai, C. Luchinat, and T. J. Meade, " Mechanistic studies of a calcium-dependent MRI contrast agent., " Inorg. Chem. 41, 4018-4024 (2002).
    • (2002) Inorg. Chem. , vol.41 , pp. 4018-4024
    • Li, W.H.1    Parigi, G.2    Fragai, M.3    Luchinat, C.4    Meade, T.J.5
  • 14
    • 0033577002 scopus 로고    scopus 로고
    • A calcium-sensitive magnetic resonance imaging contrast agent
    • W. H. Li, S. E. Fraser, and T. J. Meade, " A calcium-sensitive magnetic resonance imaging contrast agent., " J. Am. Chem. Soc. 121, 1413-1414 (1999).
    • (1999) J. Am. Chem. Soc. , vol.121 , pp. 1413-1414
    • Li, W.H.1    Fraser, S.E.2    Meade, T.J.3
  • 15
    • 0034812815 scopus 로고    scopus 로고
    • PH-dependent modulation of relaxivity and luminescence in macrocyclic gadolinium and europium complexes based on reversible intramolecular sulfonamide ligation
    • M. P. Lowe, D. Parker, O. Reany, S. Aime, M. Botta, G. Castellano, E. Gianolio, and R. Pagliarin, " pH-dependent modulation of relaxivity and luminescence in macrocyclic gadolinium and europium complexes based on reversible intramolecular sulfonamide ligation., " J. Am. Chem. Soc. 123, 7601-7609 (2001).
    • (2001) J. Am. Chem. Soc. , vol.123 , pp. 7601-7609
    • Lowe, M.P.1    Parker, D.2    Reany, O.3    Aime, S.4    Botta, M.5    Castellano, G.6    Gianolio, E.7    Pagliarin, R.8
  • 16
    • 0035801531 scopus 로고    scopus 로고
    • Magnetic nanosensors for the detection of oligonucleotide sequences
    • L. Josephson, J. M. Perez, and R. Weissleder, " Magnetic nanosensors for the detection of oligonucleotide sequences., " Angew. Chem., Int. Ed. 40, 3204-3206 (2001).
    • (2001) Angew. Chem., Int. Ed. , vol.40 , pp. 3204-3206
    • Josephson, L.1    Perez, J.M.2    Weissleder, R.3
  • 17
    • 0036892244 scopus 로고    scopus 로고
    • Remote control of catheter tip deflection: An opportunity for interventional MRI
    • T. P. Roberts, W. V. Hassenzahl, S. W. Hetts, and R. L. Arenson, " Remote control of catheter tip deflection: An opportunity for interventional MRI., " Magn. Reson. Med. 48, 1091-1095 (2002).
    • (2002) Magn. Reson. Med. , vol.48 , pp. 1091-1095
    • Roberts, T.P.1    Hassenzahl, W.V.2    Hetts, S.W.3    Arenson, R.L.4
  • 18
    • 34547470049 scopus 로고    scopus 로고
    • Factors affecting remote control catheter steering in interventional MRI: Pulse sequence optimization and an equation for predicting deflection
    • F. Settecase, Sussman, MS, Roberts, TPL, " Factors affecting remote control catheter steering in interventional MRI: pulse sequence optimization and an equation for predicting deflection., " Med. Phys. 32, 1889 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 1889
    • Settecase, F.1    Sussman, M.S.2    Roberts, T.P.L.3
  • 19
    • 0037263233 scopus 로고    scopus 로고
    • Variations in epidural catheter manufacture: Implications for bending and stiffness
    • D. M. Eckmann, " Variations in epidural catheter manufacture: implications for bending and stiffness., " Reg. Anesth. Pain Med. 28, 37-42 (2003).
    • (2003) Reg. Anesth. Pain Med. , vol.28 , pp. 37-42
    • Eckmann, D.M.1
  • 20
    • 85027229658 scopus 로고
    • edited by P.Han (The Materials Information Society, Materials Park, OH
    • W. F. Hosford, in Tensile Testing, edited by, P. Han, (The Materials Information Society, Materials Park, OH, 1992), p. 17.
    • (1992) Tensile Testing , pp. 17
    • Hosford, W.F.1
  • 21
    • 30344441834 scopus 로고    scopus 로고
    • Buckling test as a new approach to testing flexural rigidities of angiographic catheters
    • J. Carey, D. Emery, and P. McCracken, " Buckling test as a new approach to testing flexural rigidities of angiographic catheters., " J. Biomed. Mater. Res., Part B: Appl. Biomater. 76, 211-218 (2006).
    • (2006) J. Biomed. Mater. Res., Part B: Appl. Biomater. , vol.76 , pp. 211-218
    • Carey, J.1    Emery, D.2    McCracken, P.3
  • 22
    • 0142212363 scopus 로고    scopus 로고
    • Tensile strength of 19- and 20-gauge arrow epidural catheters
    • B. C. Tsui and B. Finucane, " Tensile strength of 19- and 20-gauge arrow epidural catheters., " Anesth. Analg. (Paris) 97, 1524-1526 (2003).
    • (2003) Anesth. Analg. (Paris) , vol.97 , pp. 1524-1526
    • Tsui, B.C.1    Finucane, B.2
  • 23
    • 1842429552 scopus 로고    scopus 로고
    • Active device tracking and high-resolution intravascular MRI using a novel catheter-based, opposed-solenoid phased array coil
    • C. M. Hillenbrand, D. R. Elgort, E. Y. Wong, A. Reykowski, F. K. Wacker, J. S. Lewin, and J. L. Duerk, " Active device tracking and high-resolution intravascular MRI using a novel catheter-based, opposed-solenoid phased array coil., " Magn. Reson. Med. 51, 668-675 (2004).
    • (2004) Magn. Reson. Med. , vol.51 , pp. 668-675
    • Hillenbrand, C.M.1    Elgort, D.R.2    Wong, E.Y.3    Reykowski, A.4    Wacker, F.K.5    Lewin, J.S.6    Duerk, J.L.7
  • 25
    • 2342641559 scopus 로고    scopus 로고
    • Visualization and tracking of an inflatable balloon catheter using SSFP in a flow phantom and in the heart and great vessels of patients
    • M. E. Miquel, S. Hegde, V. Muthurangu, B. J. Corcoran, S. F. Keevil, D. L. Hill, and R. S. Razavi, " Visualization and tracking of an inflatable balloon catheter using SSFP in a flow phantom and in the heart and great vessels of patients., " Magn. Reson. Med. 51, 988-995 (2004).
    • (2004) Magn. Reson. Med. , vol.51 , pp. 988-995
    • Miquel, M.E.1    Hegde, S.2    Muthurangu, V.3    Corcoran, B.J.4    Keevil, S.F.5    Hill, D.L.6    Razavi, R.S.7
  • 26
    • 0031831282 scopus 로고    scopus 로고
    • Causes and management of aneurysmal hemorrhage occurring during embolization with Guglielmi detachable coils
    • C. G. McDougall, V. V. Halbach, C. F. Dowd, R. T. Higashida, D. W. Larsen, and G. B. Hieshima, " Causes and management of aneurysmal hemorrhage occurring during embolization with Guglielmi detachable coils., " J. Neurosurg. 89, 87-92 (1998).
    • (1998) J. Neurosurg. , vol.89 , pp. 87-92
    • McDougall, C.G.1    Halbach, V.V.2    Dowd, C.F.3    Higashida, R.T.4    Larsen, D.W.5    Hieshima, G.B.6
  • 27
    • 1842296356 scopus 로고    scopus 로고
    • Guglielmi detachable coil embolization of acute intracranial aneurysm: Perioperative anatomical and clinical outcome in 403 patients
    • F. Vinuela, G. Duckwiler, and M. Mawad, " Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients., " J. Neurosurg. 86, 475-482 (1997).
    • (1997) J. Neurosurg. , vol.86 , pp. 475-482
    • Vinuela, F.1    Duckwiler, G.2    Mawad, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.