메뉴 건너뛰기




Volumn 50, Issue 4, 2005, Pages 681-694

Consistency test of the electron transport algorithm in the GEANT4 Monte Carlo code

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; IONIZATION; IONIZATION CHAMBERS; MONTE CARLO METHODS; PHOTONS;

EID: 14644444543     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/50/4/008     Document Type: Article
Times cited : (59)

References (15)
  • 2
    • 0000762173 scopus 로고
    • Monte Carlo calculation of the penetration and diffusion of fast charged particles
    • B Alder, S Fernbach and M Rotenberg (New York: Academic)
    • Berger M J 1963 Monte Carlo calculation of the penetration and diffusion of fast charged particles Methods in Computational Physics vol 1, ed B Alder, S Fernbach and M Rotenberg (New York: Academic) pp 135-215
    • (1963) Methods in Computational Physics , vol.1 , pp. 135-215
    • Berger, M.J.1
  • 3
    • 0023138959 scopus 로고
    • PRESTA - The parameter reduced electron step size algorithm for electron transport
    • Bielajew A F and Rogers D W O 1987 PRESTA - the parameter reduced electron step size algorithm for electron transport Nucl. Instrum. Methods Phys. Res. B 18 165-81
    • (1987) Nucl. Instrum. Methods Phys. Res. B , vol.18 , pp. 165-181
    • Bielajew, A.F.1    Rogers, D.W.O.2
  • 5
    • 1642308605 scopus 로고    scopus 로고
    • Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics
    • Carrier J-F, Archambault L, Beaulieu L and Roy R 2004 Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics Med. Phys. 31 484-92
    • (2004) Med. Phys. , vol.31 , pp. 484-492
    • Carrier, J.-F.1    Archambault, L.2    Beaulieu, L.3    Roy, R.4
  • 6
    • 0000792876 scopus 로고
    • Note on the Bragg-Gray cavity principle for measuring energy dissipation
    • Fano U 1954 Note on the Bragg-Gray cavity principle for measuring energy dissipation Radiat. Res. 1 237-40
    • (1954) Radiat. Res. , vol.1 , pp. 237-240
    • Fano, U.1
  • 7
    • 27844480779 scopus 로고
    • The modelling of electron multiple scattering in EGS4/PRESTA and its effect on ionisation chamber response
    • Foote B J and Smyth V G 1995 The modelling of electron multiple scattering in EGS4/PRESTA and its effect on ionisation chamber response Nucl. Instrum. Methods Phys. Res. B 100 22-30
    • (1995) Nucl. Instrum. Methods Phys. Res. B , vol.100 , pp. 22-30
    • Foote, B.J.1    Smyth, V.G.2
  • 8
    • 14644432368 scopus 로고    scopus 로고
    • GEANT4 Collaboration
    • GEANT4 Collaboration 2004 Physics Reference Manual http://wwwasd.web.cern.ch/wwwasd/geant4/G4UsersDocuments/Overview/ html/index.html
    • (2004) Physics Reference Manual
  • 9
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed-history Monte Carlo simulation of electron transport: I. EGSnrc, the new EGS4 version
    • Kawrakow I 2000a Accurate condensed-history Monte Carlo simulation of electron transport: I. EGSnrc, the new EGS4 version Med. Phys. 27 485-98
    • (2000) Med. Phys. , vol.27 , pp. 485-498
    • Kawrakow, I.1
  • 10
    • 0034023628 scopus 로고    scopus 로고
    • Accurate condensed-history Monte Carlo simulation of electron transport: II. Application to ion chamber response simulation
    • Kawrakow I 2000b Accurate condensed-history Monte Carlo simulation of electron transport: II. Application to ion chamber response simulation Med. Phys. 27 499-513
    • (2000) Med. Phys. , vol.27 , pp. 499-513
    • Kawrakow, I.1
  • 11
    • 36149005290 scopus 로고
    • Multiple scattering in an infinite medium
    • Lewis H W 1950 Multiple scattering in an infinite medium Phys. Rev. 78 526-29
    • (1950) Phys. Rev. , vol.78 , pp. 526-529
    • Lewis, H.W.1
  • 12
    • 0002084046 scopus 로고
    • Simulation of dosimeter response and interface effects
    • T M Jenkins, W R Nelson and A Rindi (New York: Plenum)
    • Nahum A E 1988 Simulation of dosimeter response and interface effects Monte Carlo Transport of Electrons and Photons ed T M Jenkins, W R Nelson and A Rindi (New York: Plenum) pp 523-47
    • (1988) Monte Carlo Transport of Electrons and Photons , pp. 523-547
    • Nahum, A.E.1
  • 13
    • 14644405544 scopus 로고    scopus 로고
    • Accuracy of the photon and electron physics in GEANT4 for radiotherapy application
    • at press
    • Poon E and Verhaegen F 2005 Accuracy of the photon and electron physics in GEANT4 for radiotherapy application Med. Phys. at press
    • (2005) Med. Phys.
    • Poon, E.1    Verhaegen, F.2
  • 14
    • 0027255748 scopus 로고
    • How accurately can EGS4/PRESTA calculate ion chamber response?
    • Rogers D W O 1993 How accurately can EGS4/PRESTA calculate ion chamber response? Med. Phys. 20 319-23
    • (1993) Med. Phys. , vol.20 , pp. 319-323
    • Rogers, D.W.O.1
  • 15
    • 4644264666 scopus 로고    scopus 로고
    • Calculated and measured air-kerma response of ionization chambers in low and medium energy photon beams
    • (Montreal) (AAPM Proc. Series vol 13) (Madison, WI: Medical Physics Publishing)
    • Seuntjens J, Kawrakow I, Borg J, Hobeila F and Rogers D W O 2002 Calculated and measured air-kerma response of ionization chambers in low and medium energy photon beams Proc. Recent Developments inAccurate Radiation Dosimetry (Montreal) (AAPM Proc. Series vol 13) (Madison, WI: Medical Physics Publishing) pp 69-84
    • (2002) Proc. Recent Developments in Accurate Radiation Dosimetry , pp. 69-84
    • Seuntjens, J.1    Kawrakow, I.2    Borg, J.3    Hobeila, F.4    Rogers, D.W.O.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.