Volumn 33, Issue 8, 2007, Pages 1348-1349

Determining corneal power using Orbscan II videokeratography for IOL calculation after excimer laser surgery for myopia

Author keywords

[No Author keywords available]

Indexed keywords

CONTACT LENS; EYE EXAMINATION; HUMAN; KERATOMILEUSIS; LENS IMPLANT; LETTER; MYOPIA; PHOTOREFRACTIVE KERATECTOMY; PRIORITY JOURNAL;

EID: 34447645657     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2007.03.062     Document Type: Letter
Times cited : (6)

References (9)
  • 1
    • 0842305653 scopus 로고    scopus 로고
    • A direct method to measure the power of the central cornea after myopic laser in situ keratomileusis
    • Sónego-Krone S., López-Moreno G., Beaujon-Balbi O.V., et al. A direct method to measure the power of the central cornea after myopic laser in situ keratomileusis. Arch Ophthalmol 122 (2004) 159-166
    • (2004) Arch Ophthalmol , vol.122 , pp. 159-166
    • Sónego-Krone, S.1    López-Moreno, G.2    Beaujon-Balbi, O.V.3
  • 2
    • 0037323783 scopus 로고    scopus 로고
    • Cataract surgery in patients with prior refractive surgery
    • Hamilton D.R., and Hardten D.R. Cataract surgery in patients with prior refractive surgery. Curr Opin Ophthalmol 14 (2003) 44-53
    • (2003) Curr Opin Ophthalmol , vol.14 , pp. 44-53
    • Hamilton, D.R.1    Hardten, D.R.2
  • 3
    • 33845738187 scopus 로고    scopus 로고
    • Determining corneal power using Orbscan II videokeratography for intraocular lens calculation after excimer laser surgery for myopia
    • Qazi M.A., Cua I.Y., Roberts C.J., and Pepose J.S. Determining corneal power using Orbscan II videokeratography for intraocular lens calculation after excimer laser surgery for myopia. J Cataract Refract Surg 33 (2007) 21-30
    • (2007) J Cataract Refract Surg , vol.33 , pp. 21-30
    • Qazi, M.A.1    Cua, I.Y.2    Roberts, C.J.3    Pepose, J.S.4
  • 4
    • 14944350447 scopus 로고    scopus 로고
    • Corneal power measurement after laser in situ keratomileusis
    • [letter]
    • Arce C.G., Schor P., and Campos M. Corneal power measurement after laser in situ keratomileusis. [letter]. Arch Ophthalmol 123 (2005) 410-411
    • (2005) Arch Ophthalmol , vol.123 , pp. 410-411
    • Arce, C.G.1    Schor, P.2    Campos, M.3
  • 5
    • 0033485849 scopus 로고    scopus 로고
    • Accuracy of Orbscan total optical power maps in detecting refractive change after myopic laser in situ keratomileusis
    • Srivannaboon S., Reinstein D.Z., Sutton H.F.S., and Holland S.P. Accuracy of Orbscan total optical power maps in detecting refractive change after myopic laser in situ keratomileusis. J Cataract Refract Surg 25 (1999) 1596-1599
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1596-1599
    • Srivannaboon, S.1    Reinstein, D.Z.2    Sutton, H.F.S.3    Holland, S.P.4
  • 6
    • 0842280543 scopus 로고    scopus 로고
    • O cálculo do poder das lentes intra-oculares e o Orbscan-II. Parte I: O poder óptico da córnea normal. [Power calculation of intraocular lenses and the Orbscan-II. Part I: the power of the normal cornea.]
    • Accessed March 23, 2007
    • Canarim de Oliveira E.C., Arce C.G., Campos M.S., and Schor P. O cálculo do poder das lentes intra-oculares e o Orbscan-II. Parte I: O poder óptico da córnea normal. [Power calculation of intraocular lenses and the Orbscan-II. Part I: the power of the normal cornea.]. Arq Bras Oftalmol 66 (2003) 567-574. http://www.scielo.br/pdf/abo/v66n5/18141.pdf Accessed March 23, 2007
    • (2003) Arq Bras Oftalmol , vol.66 , pp. 567-574
    • Canarim de Oliveira, E.C.1    Arce, C.G.2    Campos, M.S.3    Schor, P.4
  • 7
    • 34447636885 scopus 로고    scopus 로고
    • O futuro: Orbscan no cálculo da lente intra-ocular
    • Centurion V. (Ed), Cultura Médica, Rio de Janeiro, Brazil
    • Arce C.G., Rocha K.M., and Soriano E.S. O futuro: Orbscan no cálculo da lente intra-ocular. In: Centurion V. (Ed). Excelência em Biometria (2006), Cultura Médica, Rio de Janeiro, Brazil 313-320
    • (2006) Excelência em Biometria , pp. 313-320
    • Arce, C.G.1    Rocha, K.M.2    Soriano, E.S.3
  • 8
    • 33846283061 scopus 로고    scopus 로고
    • Sectorial and annular quantitative area pachymetry with the Orbscan II
    • Arce C.G., Martiz J., Alzamora J.B., et al. Sectorial and annular quantitative area pachymetry with the Orbscan II. J Refract Surg 23 (2007) 89-92
    • (2007) J Refract Surg , vol.23 , pp. 89-92
    • Arce, C.G.1    Martiz, J.2    Alzamora, J.B.3
  • 9
    • 34447623325 scopus 로고    scopus 로고
    • Características do Orbscan (Bausch & Lomb)
    • Vieira Netto M., Ambrósio Jr. R., Schor P., et al. (Eds), Editora Cultura Médica, Rio de Janeiro, Brazil
    • Arce C.G., and Francesconi C.M. Características do Orbscan (Bausch & Lomb). In: Vieira Netto M., Ambrósio Jr. R., Schor P., et al. (Eds). Wavefront, Topografia e Tomografia da Córnea e Segmento Anterior (2006), Editora Cultura Médica, Rio de Janeiro, Brazil 123-139
    • (2006) Wavefront, Topografia e Tomografia da Córnea e Segmento Anterior , pp. 123-139
    • Arce, C.G.1    Francesconi, C.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.