메뉴 건너뛰기




Volumn 57, Issue 3, 2007, Pages 185-193

Biosensors for biological warfare agent detection

Author keywords

Biological warfare agents; Biosensors; Electrochemical biosensors; Optical biosensors; Piezoelectric biosensors

Indexed keywords

BACTERIA; CHEMICAL WARFARE; ELECTROCHEMICAL SENSORS; MILITARY APPLICATIONS; PIEZOELECTRIC TRANSDUCERS;

EID: 34249319788     PISSN: 0011748X     EISSN: None     Source Type: Journal    
DOI: 10.14429/dsj.57.1760     Document Type: Article
Times cited : (49)

References (50)
  • 1
    • 0031112046 scopus 로고    scopus 로고
    • The economic impact of a bioterrorist attack: Are prevention and post-attack intervention programs justifiable?
    • Kaufmann, A.F.; Meltzer, M.I. & Schmid, G.P. The economic impact of a bioterrorist attack: Are prevention and post-attack intervention programs justifiable? Emerg. Infect. Dis., 1997, 3, 83-94.
    • (1997) Emerg. Infect. Dis , vol.3 , pp. 83-94
    • Kaufmann, A.F.1    Meltzer, M.I.2    Schmid, G.P.3
  • 3
    • 0027090488 scopus 로고
    • History of biological warfare: Catapults to capsomeres
    • Poupard, J.A. & Miller, L.A. History of biological warfare: Catapults to capsomeres. Ann. N.Y. Acad. Sci., 1992, 666, 9-20.
    • (1992) Ann. N.Y. Acad. Sci , vol.666 , pp. 9-20
    • Poupard, J.A.1    Miller, L.A.2
  • 4
    • 0027055684 scopus 로고
    • Japanese biological warfare research on humans: A case study on microbiology and ethics
    • Harris, S. Japanese biological warfare research on humans: A case study on microbiology and ethics. Ann. N.Y. Acad. Sci., 1992, 666, 21-52.
    • (1992) Ann. N.Y. Acad. Sci , vol.666 , pp. 21-52
    • Harris, S.1
  • 5
    • 0032845955 scopus 로고    scopus 로고
    • Nuclear blindness: An overview of the biological of the biological weapons programs of the former Soviet Union and Iraq
    • Davis, C.J. Nuclear blindness: An overview of the biological of the biological weapons programs of the former Soviet Union and Iraq. Emerg. Infect. Dis., 1999, 5, 509-12.
    • (1999) Emerg. Infect. Dis , vol.5 , pp. 509-512
    • Davis, C.J.1
  • 6
    • 0028159234 scopus 로고    scopus 로고
    • Meselson, M.; Guillemin, J.; Hugh-Jones, M.; Langmuir, A.; Popova, I.; Sherlokov, A. & Yampolskaya, O. The Sverdlovsk anthrax outbreak of 1979. Science, 1994, 266, 1202-208.
    • Meselson, M.; Guillemin, J.; Hugh-Jones, M.; Langmuir, A.; Popova, I.; Sherlokov, A. & Yampolskaya, O. The Sverdlovsk anthrax outbreak of 1979. Science, 1994, 266, 1202-208.
  • 10
    • 0346789278 scopus 로고    scopus 로고
    • Advances in electrochemical immunosensors
    • Skládal, P. Advances in electrochemical immunosensors. Electroanalysis, 1997, 9, 737-43.
    • (1997) Electroanalysis , vol.9 , pp. 737-743
    • Skládal, P.1
  • 11
    • 16344378710 scopus 로고
    • Rapid immunofiltration assay of Francisella tularensis. Defence Research Establishment Suffield, Canada
    • Thompson, H.G. & Lee, W.E. Rapid immunofiltration assay of Francisella tularensis. Defence Research Establishment Suffield, Canada. Suffield Memorandum No. 1376, 1992, 1-17.
    • (1992) Suffield Memorandum No , vol.1376 , pp. 1-17
    • Thompson, H.G.1    Lee, W.E.2
  • 12
    • 0011725696 scopus 로고
    • Characteristics of the biochemical detector sensor. Defence Research Establishment Suffield, Canada
    • Lee, W.E.; Thomson, H.G.; Hall, J.G.; Fulton, R.E. Wong, J.P. Characteristics of the biochemical detector sensor. Defence Research Establishment Suffield, Canada. Suffield Memorandum No. 1402, 1993, 1-23.
    • (1993) Suffield Memorandum No , vol.1402 , pp. 1-23
    • Lee, W.E.1    Thomson, H.G.2    Hall, J.G.3    Fulton, R.E.4    Wong, J.P.5
  • 14
    • 0031910714 scopus 로고    scopus 로고
    • Ghindilis, A.L.; Atanasov, P.; Wilkins, P. & Wilkins, E. Immunosensors: Electrochemical sensing and other engineering approaches. Biosensors Bioelectronics, 1998, 13, 113-31.
    • Ghindilis, A.L.; Atanasov, P.; Wilkins, P. & Wilkins, E. Immunosensors: Electrochemical sensing and other engineering approaches. Biosensors Bioelectronics, 1998, 13, 113-31.
  • 15
    • 0025186991 scopus 로고
    • An improved amperometric immunosensor for the detection and enumeration of protein A-bearing Staphylococcus aureus
    • Mirhabibollahi, B.; Brooks, J.L. & Kroll, R.G. An improved amperometric immunosensor for the detection and enumeration of protein A-bearing Staphylococcus aureus. Lett. Appl. Microbiol., 1990, 11(3), 119-22.
    • (1990) Lett. Appl. Microbiol , vol.11 , Issue.3 , pp. 119-122
    • Mirhabibollahi, B.1    Brooks, J.L.2    Kroll, R.G.3
  • 16
    • 0033054044 scopus 로고    scopus 로고
    • Increasing the sensitivity of Listeria monocytogenes assays: Evaluation using ELISA and amperometric detection
    • Crowley, E.L.; O'Sullivan, C.K. & Guilbault, G.G. Increasing the sensitivity of Listeria monocytogenes assays: Evaluation using ELISA and amperometric detection. Analyst, 1999, 124(3), 295-99.
    • (1999) Analyst , vol.124 , Issue.3 , pp. 295-299
    • Crowley, E.L.1    O'Sullivan, C.K.2    Guilbault, G.G.3
  • 17
    • 20144386029 scopus 로고    scopus 로고
    • Amperometric enzyme immunosenor for determination of Klebsiella pneumoniae antigen
    • Safina, G.R.; Mediantseva, E.P.; Vanjagina, O.N.; Glushko, N.I. & Budnikov, G.K. Amperometric enzyme immunosenor for determination of Klebsiella pneumoniae antigen. Biomed. Khim., 2005, 51(2), 212-19.
    • (2005) Biomed. Khim , vol.51 , Issue.2 , pp. 212-219
    • Safina, G.R.1    Mediantseva, E.P.2    Vanjagina, O.N.3    Glushko, N.I.4    Budnikov, G.K.5
  • 18
    • 85039238460 scopus 로고    scopus 로고
    • Skládal, P.; Symerská, Y.; Pohanka, M.; Safar, B. & Macela, A. Electrochemical immunosensor for detection of Francisella tularensis. In Defence against bioterror. detection technologies, implementation strategies and commercial opportunities, edited by Dennis Morrison, et al. Springer, Netherland, 2005. pp. 221-32.
    • Skládal, P.; Symerská, Y.; Pohanka, M.; Safar, B. & Macela, A. Electrochemical immunosensor for detection of Francisella tularensis. In Defence against bioterror. detection technologies, implementation strategies and commercial opportunities, edited by Dennis Morrison, et al. Springer, Netherland, 2005. pp. 221-32.
  • 19
    • 13844255293 scopus 로고    scopus 로고
    • Amperometric immunosensor for detection of antibodies of Salmonella typhi in patient serum
    • Rao, V.K.; Rai, G.P; Agarwal, G.S. & Suresh, S. Amperometric immunosensor for detection of antibodies of Salmonella typhi in patient serum. Anal. Chim. Acta., 2005, 531, 173-77.
    • (2005) Anal. Chim. Acta , vol.531 , pp. 173-177
    • Rao, V.K.1    Rai, G.P.2    Agarwal, G.S.3    Suresh, S.4
  • 21
    • 0027977612 scopus 로고
    • Rapid detection of Salmonella by means of a new impedance-splitting method
    • Pless, P.; Futschik, K. & Schopf, E. Rapid detection of Salmonella by means of a new impedance-splitting method. J. Food Protect., 1994, 57, 369-76.
    • (1994) J. Food Protect , vol.57 , pp. 369-376
    • Pless, P.1    Futschik, K.2    Schopf, E.3
  • 22
    • 0028329344 scopus 로고
    • Autofluorescence detection of Escherichia coli on silver membrane filters
    • Glazier, S.A. & Weetall, H.H. Autofluorescence detection of Escherichia coli on silver membrane filters. J. Microbiol. Methods, 1994, 20, 23-27.
    • (1994) J. Microbiol. Methods , vol.20 , pp. 23-27
    • Glazier, S.A.1    Weetall, H.H.2
  • 23
    • 4344640133 scopus 로고    scopus 로고
    • Rapid detection of Bacillus anthracis spores directly from powders with an evanescent wave fiber-optic biosensor
    • Tims, T.B. & Lim, D.V. Rapid detection of Bacillus anthracis spores directly from powders with an evanescent wave fiber-optic biosensor. J. Microbiol. Methods, 2004, 59(1), 127-30.
    • (2004) J. Microbiol. Methods , vol.59 , Issue.1 , pp. 127-130
    • Tims, T.B.1    Lim, D.V.2
  • 24
    • 0026768221 scopus 로고
    • Detection of receptor ligand interactions using surface plasmon resonance: Model studies employing the HIV-1 GP120/ CD4 interaction
    • Bringham-Burke, M.; Edwards, J.R. & O'Shannessy, D.J. Detection of receptor ligand interactions using surface plasmon resonance: Model studies employing the HIV-1 GP120/ CD4 interaction. J. Anal. Biochem., 1992, 205, 125-31.
    • (1992) J. Anal. Biochem , vol.205 , pp. 125-131
    • Bringham-Burke, M.1    Edwards, J.R.2    O'Shannessy, D.J.3
  • 25
    • 0032078678 scopus 로고    scopus 로고
    • Measurement of clostridium perfringens beta-toxin production by surface plasmon resonance immunoassay
    • Hsieh, H.V.; Stewart, B.; Hauer, P.; Haaland, P. & Campbell, R. Measurement of clostridium perfringens beta-toxin production by surface plasmon resonance immunoassay. Vaccine, 1998, 16, 997-1003.
    • (1998) Vaccine , vol.16 , pp. 997-1003
    • Hsieh, H.V.1    Stewart, B.2    Hauer, P.3    Haaland, P.4    Campbell, R.5
  • 26
    • 12844253252 scopus 로고    scopus 로고
    • The fabrication of protein chip based on surface plasmon resonance for detection of pathogens
    • Oh, B.K.; Lee, W.; Chun, B.S.; Bae, Y.M.; Lee, W.H. & Choi, J.W. The fabrication of protein chip based on surface plasmon resonance for detection of pathogens. Biosensors Bioelectronics, 2005, 20, 1847-850.
    • (2005) Biosensors Bioelectronics , vol.20 , pp. 1847-1850
    • Oh, B.K.1    Lee, W.2    Chun, B.S.3    Bae, Y.M.4    Lee, W.H.5    Choi, J.W.6
  • 28
    • 0030766396 scopus 로고    scopus 로고
    • Hartman interferometer: Versatile integrated optic sensor for label-free, real-time quantification of nucleic acids, proteins, and pathogens
    • Schneider, B.H.; Edwards, J.G. & Hartman, N.F. Hartman interferometer: Versatile integrated optic sensor for label-free, real-time quantification of nucleic acids, proteins, and pathogens. Clinical Chemistry, 1997, 43(9), 1757-763.
    • (1997) Clinical Chemistry , vol.43 , Issue.9 , pp. 1757-1763
    • Schneider, B.H.1    Edwards, J.G.2    Hartman, N.F.3
  • 29
    • 0028796386 scopus 로고
    • Detection of Yersinia pestis Fraction 1 antigen with a fiber optic biosensor
    • Cao, K.L.; Anderson, G.P.; Ligler, F.S. & Ezzel, J. Detection of Yersinia pestis Fraction 1 antigen with a fiber optic biosensor. J. Clin. Microbiol., 1995, 33, 336-41.
    • (1995) J. Clin. Microbiol , vol.33 , pp. 336-341
    • Cao, K.L.1    Anderson, G.P.2    Ligler, F.S.3    Ezzel, J.4
  • 30
    • 85039235346 scopus 로고    scopus 로고
    • Wijesuriya, D.C.; Anderson, G.P. & Ligler, F.S. A rapid and sensitive immunoassay for bacterial cells. In Proceedings of the 1993 ERDEC Scientific Conference on Chemical Defence Research, edited by D.A. Berg; J.D. Williams; J. Reeves & P.J. Reeves. Report No. ERDEC-SP-024 16-19 November 1993, Maryland, 1994, pp. 671-77.
    • Wijesuriya, D.C.; Anderson, G.P. & Ligler, F.S. A rapid and sensitive immunoassay for bacterial cells. In Proceedings of the 1993 ERDEC Scientific Conference on Chemical Defence Research, edited by D.A. Berg; J.D. Williams; J. Reeves & P.J. Reeves. Report No. ERDEC-SP-024 16-19 November 1993, Maryland, 1994, pp. 671-77.
  • 32
    • 0642309737 scopus 로고    scopus 로고
    • A microfluidic biosensor based on nucleic acid sequence recognition
    • Kwakye, S. & Baumner, A. A microfluidic biosensor based on nucleic acid sequence recognition. Anal. Bioanal. Chem., 2003, 376, 1062-068.
    • (2003) Anal. Bioanal. Chem , vol.376 , pp. 1062-1068
    • Kwakye, S.1    Baumner, A.2
  • 33
    • 0033967650 scopus 로고    scopus 로고
    • Optical flow-cell multichannel immunosensor for the detection of biological warfare agents
    • Koch, S.; Wolf, H.; Danapel, C. & Feller, K.A. Optical flow-cell multichannel immunosensor for the detection of biological warfare agents. Biosensors Bioelectronics., 2000, 14, 779-84.
    • (2000) Biosensors Bioelectronics , vol.14 , pp. 779-784
    • Koch, S.1    Wolf, H.2    Danapel, C.3    Feller, K.A.4
  • 34
    • 0025404361 scopus 로고
    • Development of a piezoelectric immunosensor for the detection of Salmonella typhimurium
    • Prusak-Sochaczewski, E.; Luong, J.H.T. & Guilbault, G.G. Development of a piezoelectric immunosensor for the detection of Salmonella typhimurium. Enzyme Microbiol. Technol., 1990, 12, 173-77.
    • (1990) Enzyme Microbiol. Technol , vol.12 , pp. 173-177
    • Prusak-Sochaczewski, E.1    Luong, J.H.T.2    Guilbault, G.G.3
  • 35
    • 0026832837 scopus 로고
    • Development of a piezoelectric immunosensor for the detection of Enterobacteria
    • Plomer, M.; Guilbault, G.G. & Hock, B. Development of a piezoelectric immunosensor for the detection of Enterobacteria. Enzyme Microb. Technol., 1992, 14, 230-35.
    • (1992) Enzyme Microb. Technol , vol.14 , pp. 230-235
    • Plomer, M.1    Guilbault, G.G.2    Hock, B.3
  • 37
    • 0036015962 scopus 로고    scopus 로고
    • Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance
    • Wong, Y.Y.; Ng, S.P.; Ng, M.H.; Si, S.H.; Yao, S.Z. & Fung, Y.S. Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance. Biosensors Bioelectronics, 2002, 17, 676-84.
    • (2002) Biosensors Bioelectronics , vol.17 , pp. 676-684
    • Wong, Y.Y.1    Ng, S.P.2    Ng, M.H.3    Si, S.H.4    Yao, S.Z.5    Fung, Y.S.6
  • 38
    • 3042782804 scopus 로고    scopus 로고
    • Piezoelectric immunosensor for SARS-associated corona virus in sputum
    • Zuo, B.; Li, S.; Guo, Z.; Zhang, J. & Chen, C. Piezoelectric immunosensor for SARS-associated corona virus in sputum. Anal. Chem., 2004, 76, 3536-540.
    • (2004) Anal. Chem , vol.76 , pp. 3536-3540
    • Zuo, B.1    Li, S.2    Guo, Z.3    Zhang, J.4    Chen, C.5
  • 39
    • 16344389544 scopus 로고    scopus 로고
    • Piezoelectric immunosensor for Francisella tularensis detection using immunoglobulin M in a limiting dilution
    • Pohanka, M. & Skládal, P. Piezoelectric immunosensor for Francisella tularensis detection using immunoglobulin M in a limiting dilution. Analytical Letters, 2005, 38, 411-22.
    • (2005) Analytical Letters , vol.38 , pp. 411-422
    • Pohanka, M.1    Skládal, P.2
  • 40
    • 0030220620 scopus 로고    scopus 로고
    • Detection of bacterial-contamination, including Bacillus spores, in dry growth media and in milk by identification of their 16SR DNA by polymerase chain-reaction
    • Sperveslage, J.; Stackebrandt, E.; Lembke, F.W. & Koch, C. Detection of bacterial-contamination, including Bacillus spores, in dry growth media and in milk by identification of their 16SR DNA by polymerase chain-reaction. J. Microbiol. Methods, 1996, 26, 219-24.
    • (1996) J. Microbiol. Methods , vol.26 , pp. 219-224
    • Sperveslage, J.1    Stackebrandt, E.2    Lembke, F.W.3    Koch, C.4
  • 42
    • 20244370496 scopus 로고    scopus 로고
    • Detection of Francisella tularensis in biological speciments using a capture enzyme-linked immunosorbent assay, an immunochromatographic hand-held assay, and a PCR
    • Grunow, R.; Splettstoesser, W.; McDonald, S.; Otterbein, C.; O'Brien, T.; Morgan, C.; Aldrich, J.; Hofer, E.; Finke, E.J. & Meyer, H. Detection of Francisella tularensis in biological speciments using a capture enzyme-linked immunosorbent assay, an immunochromatographic hand-held assay, and a PCR. Clin. Diagn. Lab. Immunol., 2000, 7(1), 86-90.
    • (2000) Clin. Diagn. Lab. Immunol , vol.7 , Issue.1 , pp. 86-90
    • Grunow, R.1    Splettstoesser, W.2    McDonald, S.3    Otterbein, C.4    O'Brien, T.5    Morgan, C.6    Aldrich, J.7    Hofer, E.8    Finke, E.J.9    Meyer, H.10
  • 43
    • 0033828042 scopus 로고    scopus 로고
    • Rapid characterisation of spores of Bacillus cereus group bacteia by matrix-assisted laser desorption-ionization time-of-flight mass spectrometry
    • Ryzhov, V.; Hathout, Y. & Fenselau, C. Rapid characterisation of spores of Bacillus cereus group bacteia by matrix-assisted laser desorption-ionization time-of-flight mass spectrometry. Appl. Environ. Microbiol., 2000, 66, 3828-834.
    • (2000) Appl. Environ. Microbiol , vol.66 , pp. 3828-3834
    • Ryzhov, V.1    Hathout, Y.2    Fenselau, C.3
  • 44
    • 0037372736 scopus 로고    scopus 로고
    • Repeatability and pattern recognition of bacterial fatty acid profiles generated by direct mass spectrometric analysis of in situ thermal hydrolysis/methylation of whole cells
    • Xu, M.; Voorhees, K.J. Hadfield, T.L. Repeatability and pattern recognition of bacterial fatty acid profiles generated by direct mass spectrometric analysis of in situ thermal hydrolysis/methylation of whole cells. Talanta, 2003, 59, 577-89.
    • (2003) Talanta , vol.59 , pp. 577-589
    • Xu, M.1    Voorhees, K.J.2    Hadfield, T.L.3
  • 46
    • 9144254654 scopus 로고    scopus 로고
    • Comparison of enzyme-linked immunosorbent assay, western blotting, microagglutination, indirect immunofluorescence assay, and flow cytometry for serological diagnosis of tularemia
    • Özcürümez, M.P.; Kischel, N.; Priebe, H.; Slettstösser, W.; Finke, E.J. & Grunow, R. Comparison of enzyme-linked immunosorbent assay, western blotting, microagglutination, indirect immunofluorescence assay, and flow cytometry for serological diagnosis of tularemia. Clin. Diagn. Lab. Immun., 2004, 11, 1008-015.
    • (2004) Clin. Diagn. Lab. Immun , vol.11 , pp. 1008-1015
    • Özcürümez, M.P.1    Kischel, N.2    Priebe, H.3    Slettstösser, W.4    Finke, E.J.5    Grunow, R.6
  • 48
    • 0032170818 scopus 로고    scopus 로고
    • Comparative studies of magnetic particle-based solid phase fluorogenic and electrochemiluminiscent immunoassay
    • Yu, H. Comparative studies of magnetic particle-based solid phase fluorogenic and electrochemiluminiscent immunoassay. J. Immunol. Methods, 1998, 218, 1-8.
    • (1998) J. Immunol. Methods , vol.218 , pp. 1-8
    • Yu, H.1
  • 49
    • 0036570711 scopus 로고    scopus 로고
    • Rapid and sensitive detection of biological warfare agents using time-resolved fluorescence assays
    • Peruski, A.H.; Johnson, L.H. & Peruski, L.F. Rapid and sensitive detection of biological warfare agents using time-resolved fluorescence assays. J. Immunol. Methods, 2002, 263, 35-41.
    • (2002) J. Immunol. Methods , vol.263 , pp. 35-41
    • Peruski, A.H.1    Johnson, L.H.2    Peruski, L.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.