Volumn 531, Issue 2, 2005, Pages 173-177
|
Amperometric immunosensor for detection of antibodies of Salmonella typhi in patient serum
|
Author keywords
Amperometry; Immunosensor; Salmonella typhi; Screen printed electrode; Serum; Typhoid
|
Indexed keywords
AMPEROMETRIC SENSORS;
BIOASSAY;
DNA;
ELECTRODES;
ENZYMES;
GRAPHITE;
IMMUNOSENSORS;
PATIENT TREATMENT;
POLYSTYRENES;
SCREEN PRINTING;
BOVINE SERUM ALBUMIN (BSA);
IMMUNOSORBANT ASSAY;
SALMONELLA TYPHI;
WIDAL TEST;
ANTIBODIES;
1 NAPHTHOL;
1 NAPHTHYL PHOSPHATE;
ALKALINE PHOSPHATASE;
ALKALINE PHOSPHATASE ANTIBODY;
BACTERIUM ANTIBODY;
BOVINE SERUM ALBUMIN;
ENZYME ANTIBODY;
FLAGELLIN;
GRAPHITE;
HYBRID PROTEIN;
PHOSPHATE;
POLYSTYRENE;
RECOMBINANT DNA;
RECOMBINANT PROTEIN;
SALMONELLA TYPHI ANTIBODY;
UNCLASSIFIED DRUG;
AGGLUTINATION TEST;
AMPEROMETRIC BIOSENSOR;
ANTIBODY DETECTION;
ARTICLE;
BLOOD ANALYSIS;
CONTROLLED STUDY;
CORRELATION ANALYSIS;
ELECTROCHEMISTRY;
ELECTRODE;
ENZYME LINKED IMMUNOSORBENT ASSAY;
ENZYME SUBSTRATE;
HUMAN;
HYDROLYSIS;
IMMUNOSENSOR;
NONHUMAN;
PRIORITY JOURNAL;
RECOMBINANT DNA TECHNOLOGY;
SALMONELLA TYPHI;
SERUM;
ANTIBODIES;
BIOLOGICAL TESTS;
ELECTRODES;
ENZYMES;
SENSORS;
SILK SCREEN PRINTING;
|
EID: 13844255293
PISSN: 00032670
EISSN: None
Source Type: Journal
DOI: 10.1016/j.aca.2004.10.015 Document Type: Article |
Times cited : (49)
|
References (34)
|