Volumn 57, Issue 4, 2007, Pages 754-763

Phantom-based evaluation of geometric distortions in functional magnetic resonance and diffusion tensor imaging

Author keywords

Artifacts; Diffusion tensor imaging; Diffusion weighted image; Functional MRI; Geometric distortion; Phantom design

Indexed keywords

APPLICATION PROGRAMS; BRAIN; BRAIN MAPPING; CLUSTERING ALGORITHMS; DIFFUSION; GEOMETRY; MAGNETIC RESONANCE; MAGNETIC RESONANCE IMAGING; PHANTOMS; QUALITY ASSURANCE; SCANNING; TENSORS;

EID: 34248356674     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21218     Document Type: Article
Times cited : (18)

References (20)
  • 1
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin echoes
    • Mansfield P. Multi-planar image formation using NMR spin echoes. J Phy C: Solid State Phys 1977;10:L55-L58.
    • (1977) J Phy C: Solid State Phys , vol.10
    • Mansfield, P.1
  • 4
    • 0034846492 scopus 로고    scopus 로고
    • Detection and correction of geometric distortion in 3D MR images
    • Breeuwer M, Holden M, Zylka W. Detection and correction of geometric distortion in 3D MR images. Proc SPIE 2001;4322:110-120.
    • (2001) Proc SPIE , vol.4322 , pp. 110-120
    • Breeuwer, M.1    Holden, M.2    Zylka, W.3
  • 5
    • 2042542085 scopus 로고    scopus 로고
    • A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging
    • Wang D, Doddrell DM, Cowin G. A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging. Magn Reson Imaging 2004;22:529-542.
    • (2004) Magn Reson Imaging , vol.22 , pp. 529-542
    • Wang, D.1    Doddrell, D.M.2    Cowin, G.3
  • 8
    • 33646376290 scopus 로고
    • Spin diffusion measurements: Spin echoes in the presence of a time-dependent field gradient
    • Stejskal EO, Tanner JE. Spin diffusion measurements: spin echoes in the presence of a time-dependent field gradient. J Phys Chem 1965;42:288-291.
    • (1965) J Phys Chem , vol.42 , pp. 288-291
    • Stejskal, E.O.1    Tanner, J.E.2
  • 9
    • 0022947839 scopus 로고
    • The IRAF Data Reduction and Analysis System
    • Tody D. The IRAF Data Reduction and Analysis System. Proc SPIE 1986;627:733.
    • (1986) Proc SPIE , vol.627 , pp. 733
    • Tody, D.1
  • 10
    • 34248330543 scopus 로고    scopus 로고
    • Hartkens T, Rueckert D, Schnabel JA, Hawkes DJ, Hill DLG. VTK CISG registration toolkit: an open source software package for affine and non-rigid registration of single- and multimodal 3D images. Bildverarbeitung für die Medizin 2002;409-412.
    • Hartkens T, Rueckert D, Schnabel JA, Hawkes DJ, Hill DLG. VTK CISG registration toolkit: an open source software package for affine and non-rigid registration of single- and multimodal 3D images. Bildverarbeitung für die Medizin 2002;409-412.
  • 11
    • 0032593766 scopus 로고    scopus 로고
    • Image deconvolution as an aid to mammographic artifact identification. I. Basic techniques
    • Abbott P, Shearer A, O'Doherty T, van der Putten W. Image deconvolution as an aid to mammographic artifact identification. I. Basic techniques. Proc SPIE 1999;3661:698-709.
    • (1999) Proc SPIE , vol.3661 , pp. 698-709
    • Abbott, P.1    Shearer, A.2    O'Doherty, T.3    van der Putten, W.4
  • 12
    • 0034310510 scopus 로고    scopus 로고
    • Accurate alignment of functional EPI data to anatomical MRI using a physics-based distortion model
    • Studholme C, Constable RT, Duncan JS. Accurate alignment of functional EPI data to anatomical MRI using a physics-based distortion model. IEEE Trans Med Im 2000;19:1115-1127.
    • (2000) IEEE Trans Med Im , vol.19 , pp. 1115-1127
    • Studholme, C.1    Constable, R.T.2    Duncan, J.S.3
  • 13
    • 10644266195 scopus 로고    scopus 로고
    • Geometric distortion in clinical MRI systems. Part I: Evaluation using 3D phantom
    • Wang D, Strugnell W, Cowin G, Doddrell DM, Slaughter R. Geometric distortion in clinical MRI systems. Part I: Evaluation using 3D phantom. Magn Reson Imaging 2004;22:1211-1221.
    • (2004) Magn Reson Imaging , vol.22 , pp. 1211-1221
    • Wang, D.1    Strugnell, W.2    Cowin, G.3    Doddrell, D.M.4    Slaughter, R.5
  • 16
    • 10644296409 scopus 로고    scopus 로고
    • Geometric distortion in clinical MRI systems. Part II: Correction using a 3D phantom
    • Wang D, Strugnell W, Cowin G, Doddrell DM, Slaughter R. Geometric distortion in clinical MRI systems. Part II: Correction using a 3D phantom. Magn Reson Imaging 2004;22:1223-1232.
    • (2004) Magn Reson Imaging , vol.22 , pp. 1223-1232
    • Wang, D.1    Strugnell, W.2    Cowin, G.3    Doddrell, D.M.4    Slaughter, R.5
  • 17
    • 17844381354 scopus 로고    scopus 로고
    • Method for a detailed measurement of image intensity nonuniformity in magnetic resonance imaging
    • Wang D, Doddrell DM. Method for a detailed measurement of image intensity nonuniformity in magnetic resonance imaging. Med Phys 2005;32:952-960.
    • (2005) Med Phys , vol.32 , pp. 952-960
    • Wang, D.1    Doddrell, D.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.