메뉴 건너뛰기




Volumn 32, Issue 4, 2005, Pages 952-960

Method for a detailed measurement of image intensity nonuniformity in magnetic resonance imaging

Author keywords

3 D phantom; Characterization; Geometric distortion; Intensity nonuniformity; Magnetic resonance imaging (MRI); Quality assurance (QA); RF coils

Indexed keywords

GEOMETRY; MAGNETISM; PHANTOMS; QUALITY ASSURANCE; RESONANCE; SIGNAL RECEIVERS;

EID: 17844381354     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1869572     Document Type: Article
Times cited : (12)

References (9)
  • 1
    • 0025266992 scopus 로고
    • Quality assurance methods and phantoms for magnetic resonance imaging: Report of AAPM nuclear magnetic resonance Task Group No. 1
    • R. R. Price et al., "Quality assurance methods and phantoms for magnetic resonance imaging: Report of AAPM nuclear magnetic resonance Task Group No. 1." Med. Phys. 17, 287-295 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 287-295
    • Price, R.R.1
  • 2
    • 0027337849 scopus 로고
    • Performance assessment and quality control in MRI by European tests objects and protocols
    • R. A. Lerski and J. D. de Certaines. "Performance assessment and quality control in MRI by European tests objects and protocols." Magn. Reson. Imaging 11, 817-833 (1993).
    • (1993) Magn. Reson. Imaging , vol.11 , pp. 817-833
    • Lerski, R.A.1    De Certaines, J.D.2
  • 4
    • 0033857047 scopus 로고    scopus 로고
    • Image analysis methods for assessing levels of image plane nonuniformity and stochastic noise in a magnetic resonance image of a homogeneous phantom
    • P. Magnusson and L. E. Olsson, "Image analysis methods for assessing levels of image plane nonuniformity and stochastic noise in a magnetic resonance image of a homogeneous phantom," Med. Phys. 27, 1980-1994 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1980-1994
    • Magnusson, P.1    Olsson, L.E.2
  • 5
    • 0006145208 scopus 로고    scopus 로고
    • Quality control in magnetic resonance imaging
    • The Institute of Physics and Engineering in York Medicine
    • R. A. Lerski, J. de Wilde, D. Boyce, and J. Ridgeway. "Quality control in magnetic resonance imaging," IPEM Report 80. The Institute of Physics and Engineering in York Medicine (1998).
    • (1998) IPEM Report 80
    • Lerski, R.A.1    De Wilde, J.2    Boyce, D.3    Ridgeway, J.4
  • 6
    • 2042542085 scopus 로고    scopus 로고
    • A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging
    • D. M. Wang, D. M. Doddrell, and G. Cowin. "A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging." Magn. Reson. Imaging 22, 529-542 (2004).
    • (2004) Magn. Reson. Imaging , vol.22 , pp. 529-542
    • Wang, D.M.1    Doddrell, D.M.2    Cowin, G.3
  • 7
    • 4043141670 scopus 로고    scopus 로고
    • A proposed scheme for comprehensive characterization of geometric distortion measured using a 3-dimensional phantom in magnetic resonance imaging
    • D. M. Wang and D. M. Doddrell. "A proposed scheme for comprehensive characterization of geometric distortion measured using a 3-dimensional phantom in magnetic resonance imaging." Med. Phys. 31, 2212-2218 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2212-2218
    • Wang, D.M.1    Doddrell, D.M.2
  • 9
    • 0037321795 scopus 로고    scopus 로고
    • A global method based on thin-plate splines for correction of geometric distortion: An application to fluoroscopic images
    • S. Fantozzi, A. Cappello, and A. Leardini, "A global method based on thin-plate splines for correction of geometric distortion: An application to fluoroscopic images." Med. Phys. 30, 124-131 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 124-131
    • Fantozzi, S.1    Cappello, A.2    Leardini, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.