메뉴 건너뛰기




Volumn 16, Issue 2, 2007, Pages 76-86

Microtechnologies in medicine: An overview

Author keywords

Endoscopy; MEMS; Microrobotics; Microtechnology; Sensors

Indexed keywords

ANATOMY; BLOOD PRESSURE MEASUREMENT; CAPSULE ENDOSCOPY; CARDIOVASCULAR DISEASE; CHRONIC DISEASE; COCHLEA PROSTHESIS; CONFOCAL LASER MICROSCOPY; DEVICE; DIABETES MELLITUS; DIAGNOSTIC PROCEDURE; HEART RHYTHM; HUMAN; HYPERTENSION; MALIGNANT NEOPLASTIC DISEASE; MEDICAL TECHNOLOGY; MICROELECTROMECHANICAL SYSTEM; PATIENT MONITORING; POINT OF CARE TESTING; PRIORITY JOURNAL; REVIEW; ROBOTICS; SURGICAL INSTRUMENT; TELEMETRY;

EID: 34248208613     PISSN: 13645706     EISSN: 13652931     Source Type: Journal    
DOI: 10.1080/13645700701266917     Document Type: Review
Times cited : (16)

References (50)
  • 1
    • 0027614353 scopus 로고
    • Potential applications of microsystems engineering in minimal invasive surgery
    • Menz, W. and Buess, G. (1993) Potential applications of microsystems engineering in minimal invasive surgery. Endosc Surg Allied Technol, 1, pp. 171-180.
    • (1993) Endosc Surg Allied Technol , vol.1 , pp. 171-180
    • Menz, W.1    Buess, G.2
  • 2
    • 0028033903 scopus 로고
    • Microstructure technologies and their potential in medical applications
    • Menz, W. and Guber, A. (1994) Microstructure technologies and their potential in medical applications. Minim Invasive Neurosurg, 37, pp. 21-27.
    • (1994) Minim Invasive Neurosurg , vol.37 , pp. 21-27
    • Menz, W.1    Guber, A.2
  • 3
    • 0029348103 scopus 로고
    • Principles of development and design of microsystems
    • Wagner, B. (1995) Principles of development and design of microsystems. Endosc Surg Allied Technol, 3, pp. 204-209.
    • (1995) Endosc Surg Allied Technol , vol.3 , pp. 204-209
    • Wagner, B.1
  • 4
    • 2442436617 scopus 로고    scopus 로고
    • Restoring hearing with active hearing implants
    • Federspil, P. A. and Plinkert, P. K. (2004) Restoring hearing with active hearing implants. Biomed Tech (Berl), 4, pp. 78-82.
    • (2004) Biomed Tech (Berl) , vol.4 , pp. 78-82
    • Federspil, P.A.1    Plinkert, P.K.2
  • 6
    • 7544238050 scopus 로고    scopus 로고
    • Wireless remote monitoring for patients with atrial tachyarrhythmias
    • Wildau, H. J. (2004) Wireless remote monitoring for patients with atrial tachyarrhythmias. J Electrocardiol, 37, pp. 53-54.
    • (2004) J Electrocardiol , vol.37 , pp. 53-54
    • Wildau, H.J.1
  • 7
    • 28444464477 scopus 로고    scopus 로고
    • Development of Microelectromechanical Systems (MEMS) forceps for intraocular surgery
    • Bhisitkul, R. B. and Keller, C. G. (2005) Development of Microelectromechanical Systems (MEMS) forceps for intraocular surgery. Br J Ophthalmol, 89, pp. 1586-1588.
    • (2005) Br J Ophthalmol , vol.89 , pp. 1586-1588
    • Bhisitkul, R.B.1    Keller, C.G.2
  • 8
    • 23144452296 scopus 로고    scopus 로고
    • Automatic bio-sampling chips integrated with micro-pumps and micro-valves for disease detection
    • Wang, C. H. and Lee, G. B. (2005) Automatic bio-sampling chips integrated with micro-pumps and micro-valves for disease detection. Biosens Bioelectron, 15, pp. 419-425.
    • (2005) Biosens Bioelectron , vol.15 , pp. 419-425
    • Wang, C.H.1    Lee, G.B.2
  • 9
    • 33749261409 scopus 로고    scopus 로고
    • A flexible and wearable glucose sensor based on functional polymers with soft-MEMS techniques
    • Kudo, H., Sawada, T., Kazawa, E. and Yoshida, H. (2006) A flexible and wearable glucose sensor based on functional polymers with soft-MEMS techniques. Biosens Bioelectron, 22, pp. 558-562.
    • (2006) Biosens Bioelectron , vol.22 , pp. 558-562
    • Kudo, H.1    Sawada, T.2    Kazawa, E.3    Yoshida, H.4
  • 10
    • 2342522883 scopus 로고    scopus 로고
    • Applications of MEMS in surgery
    • Rebello, K. (2004) Applications of MEMS in surgery. Proceedings of the IEEE, 92:1
    • (2004) Proceedings of the IEEE , vol.92 , pp. 1
    • Rebello, K.1
  • 12
    • 0036724818 scopus 로고    scopus 로고
    • A comparison of transcutaneous bilirubinometers: SpectRx BiliCheck versus Minolta AirShields
    • Wong, C. M., van Dijk, P. J. and Laing, I. A. (2002) A comparison of transcutaneous bilirubinometers: SpectRx BiliCheck versus Minolta AirShields. Arch Dis Child Fetal Neonatal Ed, 87, p. F137.
    • (2002) Arch Dis Child Fetal Neonatal Ed , vol.87
    • Wong, C.M.1    van Dijk, P.J.2    Laing, I.A.3
  • 13
    • 0036200750 scopus 로고    scopus 로고
    • MEMS-based sample preparation for molecular diagnostics
    • Huang, Y., Mather, E. L., Bell, J. L. and Madou, M. (2002) MEMS-based sample preparation for molecular diagnostics. Anal Bioanal Chem, 372, pp. 49-65.
    • (2002) Anal Bioanal Chem , vol.372 , pp. 49-65
    • Huang, Y.1    Mather, E.L.2    Bell, J.L.3    Madou, M.4
  • 14
    • 33646862381 scopus 로고    scopus 로고
    • Application of Micro- and Nano-Electromechanical Devices to Drug Delivery
    • Staples, M., Daniel, K., Cima, M. J. and Langer, R. (2006) Application of Micro- and Nano-Electromechanical Devices to Drug Delivery. Pharm Res
    • (2006) Pharm Res
    • Staples, M.1    Daniel, K.2    Cima, M.J.3    Langer, R.4
  • 15
    • 8544229900 scopus 로고    scopus 로고
    • In vivo release from a drug delivery MEMS device
    • Li, Y., Shawgo, R. S., Tyler, B. and Henderson, P. T. (2004) In vivo release from a drug delivery MEMS device. J Control Release.100, pp. 211-219.
    • (2004) J Control Release , vol.100 , pp. 211-219
    • Li, Y.1    Shawgo, R.S.2    Tyler, B.3    Henderson, P.T.4
  • 16
    • 4544350495 scopus 로고    scopus 로고
    • Continuous on-chip micropumping for microneedle enhanced drug delivery
    • Zahn, J. D., Deshmukh, A., Pisano, A. P. and Liepmann, D. (2004) Continuous on-chip micropumping for microneedle enhanced drug delivery. Biomed Microdevices, 6, pp. 183-190.
    • (2004) Biomed Microdevices , vol.6 , pp. 183-190
    • Zahn, J.D.1    Deshmukh, A.2    Pisano, A.P.3    Liepmann, D.4
  • 17
    • 28444464477 scopus 로고    scopus 로고
    • Development of Microelectromechanical Systems (MEMS) forceps for intraocular surgery
    • Bhisitkul, R. B. and Keller, C. G. (2005) Development of Microelectromechanical Systems (MEMS) forceps for intraocular surgery. Br J Ophthalmol, 89, pp. 1586-1588.
    • (2005) Br J Ophthalmol , vol.89 , pp. 1586-1588
    • Bhisitkul, R.B.1    Keller, C.G.2
  • 19
    • 33750284702 scopus 로고    scopus 로고
    • Artificial tactile sensing in minimally invasive surgery - A new technical approach
    • Schostek, S., Ho, C. N., Kalanovic, D. and Schurr, M. O. (2006) Artificial tactile sensing in minimally invasive surgery - a new technical approach. Min Invas Ther Allied Technol, 15, pp. 296-304.
    • (2006) Min Invas Ther Allied Technol , vol.15 , pp. 296-304
    • Schostek, S.1    Ho, C.N.2    Kalanovic, D.3    Schurr, M.O.4
  • 20
    • 34248216069 scopus 로고    scopus 로고
    • A laser-scanning endoscope base on monosilicon micromachined mirrors with enhanced attributes
    • George, M., Albrecht, H. J., Schurr, M. O. and Papageorgas, P. A laser-scanning endoscope base on monosilicon micromachined mirrors with enhanced attributes., p. 5143.
    • George, M.1    Albrecht, H.J.2    Schurr, M.O.3    Papageorgas, P.4
  • 21
    • 2342495784 scopus 로고    scopus 로고
    • Optical methods and sensors for in situ histology and endoscopy
    • George, M. (2004) optical methods and sensors for in situ histology and endoscopy. Min Invas Ther & Allied Technol, 13, pp. 95-104.
    • (2004) Min Invas Ther & Allied Technol , vol.13 , pp. 95-104
    • George, M.1
  • 22
    • 33749341873 scopus 로고    scopus 로고
    • Fast-scanning two-photon fluorescence imaging based on a microelectromechanical systems two- dimensional scanning mirror
    • Piyawattanametha, W., Barretto, R. P., Ko, T. H. and Flusberg, B. A. (2006) Fast-scanning two-photon fluorescence imaging based on a microelectromechanical systems two- dimensional scanning mirror. Opt Lett, 31, pp. 2018-2020.
    • (2006) Opt Lett , vol.31 , pp. 2018-2020
    • Piyawattanametha, W.1    Barretto, R.P.2    Ko, T.H.3    Flusberg, B.A.4
  • 23
    • 18044363836 scopus 로고    scopus 로고
    • Review of the potential of a wireless MEMS and TFT microsystems for the measurement of pressure in the GI tract
    • Arshak, A., Arshak, K., Waldron, D. and Morris, D. (2005) Review of the potential of a wireless MEMS and TFT microsystems for the measurement of pressure in the GI tract. Med Eng Phys, 27, pp. 347-356.
    • (2005) Med Eng Phys , vol.27 , pp. 347-356
    • Arshak, A.1    Arshak, K.2    Waldron, D.3    Morris, D.4
  • 25
    • 33646568486 scopus 로고    scopus 로고
    • A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with non-stricturing small bowel Crohn's disease
    • Triester, S. L., Leighton, J. A., Leontiadis, G. I. and Gurudu, S. R. (2006) A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with non-stricturing small bowel Crohn's disease. Am J Gastroenterol, 101, pp. 954-964.
    • (2006) Am J Gastroenterol , vol.101 , pp. 954-964
    • Triester, S.L.1    Leighton, J.A.2    Leontiadis, G.I.3    Gurudu, S.R.4
  • 26
    • 34248206066 scopus 로고    scopus 로고
    • Value of wireless capsule endoscopy in patients with indeterminate colitis (inflammatory bowel disease type unclassified)
    • Maunoury, V., Savoye, G., Bourreille, A. and Bouhnik, Y. (2006) Value of wireless capsule endoscopy in patients with indeterminate colitis (inflammatory bowel disease type unclassified). Inflamm Bowel Dis
    • (2006) Inflamm Bowel Dis
    • Maunoury, V.1    Savoye, G.2    Bourreille, A.3    Bouhnik, Y.4
  • 27
    • 33748941287 scopus 로고    scopus 로고
    • Recent advances in endoscopic capsule imaging: See what we have been missing
    • Leighton, J. A. (2006) Recent advances in endoscopic capsule imaging: see what we have been missing. Rev Gastroenterol Disord, 6, p. S19.
    • (2006) Rev Gastroenterol Disord , vol.6
    • Leighton, J.A.1
  • 28
    • 34147175051 scopus 로고    scopus 로고
    • Wireless capsule endoscopy: From diagnostic devices to multipurpose robotic systems
    • Moglia, A., Menciassi, A., Schurr, M. O. and Dario, P. (2006) Wireless capsule endoscopy: From diagnostic devices to multipurpose robotic systems. Biomed Microdevices
    • (2006) Biomed Microdevices
    • Moglia, A.1    Menciassi, A.2    Schurr, M.O.3    Dario, P.4
  • 29
    • 0142022674 scopus 로고    scopus 로고
    • Bio-inspired solutions for locomotion in the gastrointestinal tract: Background and perspectives
    • Menciassi, A. and Dario, P. (2003) Bio-inspired solutions for locomotion in the gastrointestinal tract: Background and perspectives. Philos Transact A Math Phys Eng Sci, 361, pp. 2287-2298.
    • (2003) Philos Transact A Math Phys Eng Sci , vol.361 , pp. 2287-2298
    • Menciassi, A.1    Dario, P.2
  • 30
    • 12344284738 scopus 로고    scopus 로고
    • A micro creeping robot for colonoscopy based on the earthworm
    • Zuo, J., Yan, G. and Gao, Z. (2005) A micro creeping robot for colonoscopy based on the earthworm. J Med Eng Technol, 29, pp. 1-7.
    • (2005) J Med Eng Technol , vol.29 , pp. 1-7
    • Zuo, J.1    Yan, G.2    Gao, Z.3
  • 31
    • 0032801026 scopus 로고    scopus 로고
    • Development and in vitro testing of a miniature robotic system for computer-assisted colonoscopy
    • Dario, P., Carrozza, M. C. and Pietrabissa, A. (1999) Development and in vitro testing of a miniature robotic system for computer-assisted colonoscopy. Comput Aided Surg, 4, pp. 1-14.
    • (1999) Comput Aided Surg , vol.4 , pp. 1-14
    • Dario, P.1    Carrozza, M.C.2    Pietrabissa, A.3
  • 32
    • 0036096056 scopus 로고    scopus 로고
    • Analysis and development of locomotion devices for the gastrointestinal tract
    • Phee, L., Accoto, D., Menciassi, A. and Stefanini, C. (2002) Analysis and development of locomotion devices for the gastrointestinal tract. IEEE Trans Biomed Eng, 49, pp. 613-616.
    • (2002) IEEE Trans Biomed Eng , vol.49 , pp. 613-616
    • Phee, L.1    Accoto, D.2    Menciassi, A.3    Stefanini, C.4
  • 33
    • 0037955533 scopus 로고    scopus 로고
    • From wired to wireless: A miniature robot for intestinal inspection
    • Chi, D. and Yan, G. (2003) From wired to wireless: A miniature robot for intestinal inspection. J Med Eng Technol, 27, pp. 71-76.
    • (2003) J Med Eng Technol , vol.27 , pp. 71-76
    • Chi, D.1    Yan, G.2
  • 34
    • 11144334743 scopus 로고    scopus 로고
    • Implantable insulin delivery pumps
    • Renard, E. (2004) Implantable insulin delivery pumps. Min Invas Ther Allied Technol, 13, pp. 328-335.
    • (2004) Min Invas Ther Allied Technol , vol.13 , pp. 328-335
    • Renard, E.1
  • 35
    • 0032245675 scopus 로고    scopus 로고
    • Micromechanical pressure sensors for medical evaluation of blood vessels and bypasses after surgical intervention
    • Zacheja, J., Wenzel, D., Bach, T. and Clasbrummel, B. (1998) Micromechanical pressure sensors for medical evaluation of blood vessels and bypasses after surgical intervention. Biomed Tech (Berl), 43, pp. 182-183.
    • (1998) Biomed Tech (Berl) , vol.43 , pp. 182-183
    • Zacheja, J.1    Wenzel, D.2    Bach, T.3    Clasbrummel, B.4
  • 36
  • 37
    • 2342549690 scopus 로고    scopus 로고
    • Pressure sensors for the monitoring of diseases in surgical care
    • Clasbrummel, B., Muhr, G. and Moellenhoff, G. (2004) Pressure sensors for the monitoring of diseases in surgical care. Min Invas Ther Allied Technol, 13, pp. 105-109.
    • (2004) Min Invas Ther Allied Technol , vol.13 , pp. 105-109
    • Clasbrummel, B.1    Muhr, G.2    Moellenhoff, G.3
  • 38
    • 0036365054 scopus 로고    scopus 로고
    • Minimally invasive pressure sensor for telemetric recording of intravesical pressure in the human
    • Fischer, H., Haller, D. and Echtle, D. (2002) Minimally invasive pressure sensor for telemetric recording of intravesical pressure in the human. Biomed Tech (Berl), 47, pp. 338-341.
    • (2002) Biomed Tech (Berl) , vol.47 , pp. 338-341
    • Fischer, H.1    Haller, D.2    Echtle, D.3
  • 39
    • 4444230542 scopus 로고    scopus 로고
    • First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms
    • Ellozy, S. H., Carroccio, A., Lookstein, R. A. and Minor, M. E. (2004) First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms. J Vasc Surg, 40, pp. 405-412.
    • (2004) J Vasc Surg , vol.40 , pp. 405-412
    • Ellozy, S.H.1    Carroccio, A.2    Lookstein, R.A.3    Minor, M.E.4
  • 41
    • 0346339396 scopus 로고    scopus 로고
    • Chronically implanted epidural electrodes in Gottinger minipigs allow function tests of epiretinal implants
    • Laube, T., Schanze, T., Brockmann, C. and Bolle, I. (2003) Chronically implanted epidural electrodes in Gottinger minipigs allow function tests of epiretinal implants. Graefes Arch Clin Exp Ophthalmol, 241, pp. 1013-1019.
    • (2003) Graefes Arch Clin Exp Ophthalmol , vol.241 , pp. 1013-1019
    • Laube, T.1    Schanze, T.2    Brockmann, C.3    Bolle, I.4
  • 43
    • 26444450974 scopus 로고    scopus 로고
    • Epiretinal visual prostheses
    • Walter, P. and Mokwa, W. (2005) Epiretinal visual prostheses. Ophthalmologe, 102, pp. 933-940.
    • (2005) Ophthalmologe , vol.102 , pp. 933-940
    • Walter, P.1    Mokwa, W.2
  • 44
    • 33750957048 scopus 로고    scopus 로고
    • Compound subretinal prostheses with extra-ocular parts designed for human trials: Successful long-term implantation in pigs
    • Gekeler, F., Szurman, P., Grisanti, S. and Weiler, U. (2006) Compound subretinal prostheses with extra-ocular parts designed for human trials: successful long-term implantation in pigs. Graefes Arch Clin Exp Ophthalmol
    • (2006) Graefes Arch Clin Exp Ophthalmol
    • Gekeler, F.1    Szurman, P.2    Grisanti, S.3    Weiler, U.4
  • 45
    • 2442566634 scopus 로고    scopus 로고
    • Neural prostheses in clinical applications-trends from precision mechanics towards biomedical microsystems in neurological rehabilitation
    • Stieglitz, T., Schuettler, M. and Koch, K. P. (2004) Neural prostheses in clinical applications-trends from precision mechanics towards biomedical microsystems in neurological rehabilitation. Biomed Tech (Berl), 49, pp. 72-77.
    • (2004) Biomed Tech (Berl) , vol.49 , pp. 72-77
    • Stieglitz, T.1    Schuettler, M.2    Koch, K.P.3
  • 46
  • 47
    • 21644436666 scopus 로고    scopus 로고
    • Microrobotics and MEMS-based fabrication techniques for scaffold-based tissue engineering
    • Zhang, H., Hutmacher, D. W., Chollet, F. and Poo, A. N. (2005) Microrobotics and MEMS-based fabrication techniques for scaffold-based tissue engineering. Macromol Biosci, 5, pp. 477-489.
    • (2005) Macromol Biosci , vol.5 , pp. 477-489
    • Zhang, H.1    Hutmacher, D.W.2    Chollet, F.3    Poo, A.N.4
  • 48
    • 33747278350 scopus 로고    scopus 로고
    • Considerations for non-invasive in-flight monitoring of astronaut immune status with potential use of MEMS and NEMS devices
    • Aponte, V. M., Finch, D. S. and Klaus, D. M. (2006) Considerations for non-invasive in-flight monitoring of astronaut immune status with potential use of MEMS and NEMS devices. Life Sci, 79, pp. 1317-1333.
    • (2006) Life Sci, , vol.79 , pp. 1317-1333
    • Aponte, V.M.1    Finch, D.S.2    Klaus, D.M.3
  • 49
    • 2342496754 scopus 로고    scopus 로고
    • Technical standards for microsensors in surgery and minimally invasive therapy
    • Neuder, K. and Dehm, J. (2004) Technical standards for microsensors in surgery and minimally invasive therapy. Min Invas Ther Allied Technol, 13, pp. 110-113.
    • (2004) Min Invas Ther Allied Technol , vol.13 , pp. 110-113
    • Neuder, K.1    Dehm, J.2
  • 50
    • 2342662190 scopus 로고    scopus 로고
    • Innovation requirements for telemetric sensor systems in medicine: Results of a survey in Germany
    • Kalanovic, D. and Schurr, M. O. (2004) Innovation requirements for telemetric sensor systems in medicine: Results of a survey in Germany. Min Invas Ther Allied Technol, 13, pp. 68-77.
    • (2004) Min Invas Ther Allied Technol , vol.13 , pp. 68-77
    • Kalanovic, D.1    Schurr, M.O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.