메뉴 건너뛰기




Volumn 22, Issue 1, 2007, Pages 125-129

Implementing dosimetry in GATE: Dose-point kernel validation with GEANT4 4.8.1

Author keywords

Dosimetry; Monte Carlo simulation; Radiotherapy

Indexed keywords

ALGORITHM; CONFERENCE PAPER; DATA BASE; DOSE CALCULATION; DOSIMETRY; ELECTRON; GEANT4 BASED APPLICATION FOR EMISSION TOMOGRAPHY; GEOMETRY AND TRACKING 4; INTERMETHOD COMPARISON; KERNEL METHOD; KOLMOGOROV SMIRNOV TEST; MONTE CARLO METHOD; PRIORITY JOURNAL; RADIATION DOSE DISTRIBUTION; STATISTICAL ANALYSIS; STATISTICAL PARAMETERS; THICKNESS; VALIDATION STUDY;

EID: 34247874664     PISSN: 10849785     EISSN: None     Source Type: Journal    
DOI: 10.1089/cbr.2007.304     Document Type: Conference Paper
Times cited : (36)

References (14)
  • 1
    • 5744251917 scopus 로고    scopus 로고
    • GATE: A simulation toolkit for PET and SPECT
    • Online document at: Accessed March 9, 2007
    • Jan S, Santin G, Strul D, et al. GATE: A simulation toolkit for PET and SPECT. Phys Med Biol 2004;49:4543. Online document at: http:// opengatecollaboration.healthgrid.org Accessed March 9, 2007.
    • (2004) Phys Med Biol , vol.49 , pp. 4543
    • Jan, S.1    Santin, G.2    Strul, D.3
  • 2
    • 0038377458 scopus 로고    scopus 로고
    • GEANT4-a simulation toolkit
    • Online document at: Accessed March 9, 2007
    • Agostinelli S, Allison J, Amako K, et al. GEANT4-a simulation toolkit. Nucl Instrum Meth Phys Res A 2003;506:250. Online document at: http://geant4.web. cern.ch/geant4 Accessed March 9, 2007.
    • (2003) Nucl Instrum Meth Phys Res A , vol.506 , pp. 250
    • Agostinelli, S.1    Allison, J.2    Amako, K.3
  • 3
    • 11244309250 scopus 로고    scopus 로고
    • Carlo dosimetric study of best industries and Alpha Omega Ir-192 brachytherapy seeds
    • Ballester F. Monte Carlo dosimetric study of best industries and Alpha Omega Ir-192 brachytherapy seeds. Med Phys 2004;31:3298.
    • (2004) Med Phys , vol.31 , pp. 3298
    • Monte, B.F.1
  • 4
    • 4043161556 scopus 로고    scopus 로고
    • Carlo dose calculation algorithm for proton therapy
    • Fippel M. A Monte Carlo dose calculation algorithm for proton therapy. Med Phys 2004;31:2263.
    • (2004) Med Phys , vol.31 , pp. 2263
    • Monte, F.M.A.1
  • 6
    • 34247872563 scopus 로고    scopus 로고
    • Hendricks JS, et al. MCNPX extensions, version 2.5.0. Los Alamos, NM: Los Alamos National Laboratory Report LA-UR-04-0570, 2004
    • Hendricks JS, et al. MCNPX extensions, version 2.5.0. Los Alamos, NM: Los Alamos National Laboratory Report LA-UR-04-0570, 2004.
  • 7
    • 0025938356 scopus 로고
    • Electron-photon Monte Carlo calculations: The ETRAN code
    • Seltzer SM. Electron-photon Monte Carlo calculations: The ETRAN code. Appl Radiat Isot 1991;42:917.
    • (1991) Appl Radiat Isot , vol.42 , pp. 917
    • Seltzer, S.M.1
  • 8
    • 34247874146 scopus 로고    scopus 로고
    • Online document at:, Accessed March 9
    • Online document at: http://physics.nist.gov/Phys RefData/Star/Text/ESTAR. html Accessed March 9, 2007.
    • (2007)
  • 9
    • 34247870929 scopus 로고    scopus 로고
    • Briesmeister JF. MCNP™-A general Monte Carlo N-particle transport code, version 4B. Los Alamos, NM: Los Alamos National Laboratory Report LA-12625-M, 1997.
    • Briesmeister JF. MCNP™-A general Monte Carlo N-particle transport code, version 4B. Los Alamos, NM: Los Alamos National Laboratory Report LA-12625-M, 1997.
  • 10
    • 14644444543 scopus 로고    scopus 로고
    • Consistency test of the electron transport algorithm in GEANT4 Monte carlo code
    • Poon E. Consistency test of the electron transport algorithm in GEANT4 Monte carlo code. Phys Med Biol 2005;50:681.
    • (2005) Phys Med Biol , vol.50 , pp. 681
    • Poon, E.1
  • 11
    • 0037035394 scopus 로고    scopus 로고
    • A comparison of MCNP4C electron transport with ITS 3.0 and experiment at incident energies between 100 and 20 MeV: Influence of voxel size, substeps, and energy indexing algorithm
    • Schaart DR, Jansen JT, Zoetelief J, et al. A comparison of MCNP4C electron transport with ITS 3.0 and experiment at incident energies between 100 and 20 MeV: Influence of voxel size, substeps, and energy indexing algorithm. Phys Med Biol 2002;47(9):1459.
    • (2002) Phys Med Biol , vol.47 , Issue.9 , pp. 1459
    • Schaart, D.R.1    Jansen, J.T.2    Zoetelief, J.3
  • 12
    • 0036798699 scopus 로고    scopus 로고
    • Parameter dependence of the MCNP electron transport in determining dose distributions
    • Reynaert N, Palmans H, Thierens H, et al. Parameter dependence of the MCNP electron transport in determining dose distributions. Med Phys 2002;29 (10):2446.
    • (2002) Med Phys , vol.29 , Issue.10 , pp. 2446
    • Reynaert, N.1    Palmans, H.2    Thierens, H.3
  • 13
    • 0000762173 scopus 로고
    • Carlo calculation of the penetration of diffusion of fast charged particles
    • Alder B, Fernbach S, and Rotenberg M, eds, New York: Academic Press
    • Berger MJ. Monte Carlo calculation of the penetration of diffusion of fast charged particles. In: Alder B, Fernbach S, and Rotenberg M, eds., Methods in Computational Physics. New York: Academic Press, 1963;135.
    • (1963) Methods in Computational Physics , pp. 135
    • Monte, B.M.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.