메뉴 건너뛰기




Volumn 31, Issue 12, 2004, Pages 3298-3305

Monte Carlo dosimetric study of Best Industries and Alpha Omega Ir-192 brachytherapy seeds

Author keywords

Brachytherapy; Dosimetry; Intracavitary sources; Ir 192; Monte Carlo simulations

Indexed keywords

ANISOTROPY; MONTE CARLO METHODS; ONCOLOGY; RADIOTHERAPY; RATE CONSTANTS;

EID: 11244309250     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1820013     Document Type: Article
Times cited : (38)

References (33)
  • 4
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, "Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43," Med. Phys. 22, 209-234 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 6
    • 0025900734 scopus 로고
    • Comparison of measured and calculated dose rates in water near 1-125 and Ir-192 seeds
    • J. F. Williamson, "Comparison of measured and calculated dose rates in water near 1-125 and Ir-192 seeds," Med. Phys. 18, 776-786 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 776-786
    • Williamson, J.F.1
  • 8
    • 0032414697 scopus 로고    scopus 로고
    • Experimental determination of dosimetry functions of Ir-192 sources
    • J. C. Anctil, B. G. Clark, and C. J. Arsenault, "Experimental determination of dosimetry functions of Ir-192 sources," Med. Phys. 25, 2279-2287 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2279-2287
    • Anctil, J.C.1    Clark, B.G.2    Arsenault, C.J.3
  • 9
    • 0031836440 scopus 로고    scopus 로고
    • 169Yb brachytherapy sources: An EGS4 Monte Carlo study
    • 169Yb brachytherapy sources: An EGS4 Monte Carlo study," Phys. Med. Biol. 43, 1557-1566 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1557-1566
    • Mainegra, E.1    Capote, R.2    López, E.3
  • 10
  • 11
    • 0034744231 scopus 로고    scopus 로고
    • 192Ir and brachytherapy sources: An EGS4 Monte Carlo study
    • 192Ir and brachytherapy sources: An EGS4 Monte Carlo study," Phys. Med. Biol. 46, 1487-1499 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1487-1499
    • Capote, R.1    Mainegra, E.2    López, E.3
  • 12
    • 0033678807 scopus 로고    scopus 로고
    • 192Ir SS sources for intravascular brachytherapy
    • 192Ir SS sources for intravascular brachytherapy," Med. Phys. 27, 2528-2535 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 2528-2535
    • Wang, R.1    Li, X.A.2
  • 13
    • 3042548128 scopus 로고    scopus 로고
    • 192Ir seed at short distances: Effects of air channels and neighboring seeds based on Monte Carlo study
    • 192Ir seed at short distances: Effects of air channels and neighboring seeds based on Monte Carlo study," Med. Phys. 31, 1521-1528 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 1521-1528
    • Patel, N.S.1    Chiu-Tsao, S.2    Shih, J.A.3    Ho, Y.4    Tsao, H.5    Harrison, B.6
  • 17
    • 3142677842 scopus 로고    scopus 로고
    • Phantom size in brachytherapy source dosimetric studies
    • J. Pérez-Calatayud, D. Granero, and F. Ballester, "Phantom size in brachytherapy source dosimetric studies," Med. Phys. 31, 2075-2081 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2075-2081
    • Pérez-Calatayud, J.1    Granero, D.2    Ballester, F.3
  • 18
    • 0038377458 scopus 로고    scopus 로고
    • GEANT4 - A Simulation Toolkit
    • S. Agostinelli et al., "GEANT4 - A Simulation Toolkit," Nucl. Instrum. Methods Phys. Res. A 506, 250-303 (2003) (see also http://geant4.web. cern.ch/geant4/).
    • (2003) Nucl. Instrum. Methods Phys. Res. A , vol.506 , pp. 250-303
    • Agostinelli, S.1
  • 19
    • 12144291169 scopus 로고    scopus 로고
    • Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: Evaluation of applicator attenuation and superposition approximation effects
    • J. Pérez-Calatayud, D. Granero, F. Ballester, V. Puchades, and E. Casal, "Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: Evaluation of applicator attenuation and superposition approximation effects," Med. Phys. 31, 493-499 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 493-499
    • Pérez-Calatayud, J.1    Granero, D.2    Ballester, F.3    Puchades, V.4    Casal, E.5
  • 20
    • 85027231339 scopus 로고    scopus 로고
    • a web-based database maintained by the National Nuclear Data Center, Brookhaven National Laboratory, Upton, NY
    • National Nuclear Data Center. Nuclear data from NUDAT, a web-based database maintained by the National Nuclear Data Center, Brookhaven National Laboratory, Upton, NY; http://www.nndc.bnl.gov/nudat2.
    • Nuclear Data from NUDAT
  • 22
    • 0031739032 scopus 로고    scopus 로고
    • Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source
    • G. M. Daskalov, E. Loffler, and J. F. Williamson, "Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source," Med. Phys. 25, 2200-2208 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2200-2208
    • Daskalov, G.M.1    Loffler, E.2    Williamson, J.F.3
  • 23
    • 0023514509 scopus 로고
    • Monte Carlo evaluation of kerma at a point for photon transport problems
    • J. F. Williamson, "Monte Carlo evaluation of kerma at a point for photon transport problems," Med. Phys. 14, 567-576 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 567-576
    • Williamson, J.F.1
  • 26
    • 0029837823 scopus 로고    scopus 로고
    • EGS4 dosimetry calculations for cylindrically symmetric brachytherapy sources
    • R. Wang and R. S. Sloboda, "EGS4 dosimetry calculations for cylindrically symmetric brachytherapy sources," Med. Phys. 23, 1459-1465 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1459-1465
    • Wang, R.1    Sloboda, R.S.2
  • 27
    • 0014286055 scopus 로고
    • The effective attenuation in water of the gamma rays of gold 198, indium 192, cesium 137, radium 226, and cobalt 60
    • L. L. Meisberger, R. Keller, and R. Shalek, "The effective attenuation in water of the gamma rays of gold 198, indium 192, cesium 137, radium 226, and cobalt 60," Radiology 90, 953-957 (1968).
    • (1968) Radiology , vol.90 , pp. 953-957
    • Meisberger, L.L.1    Keller, R.2    Shalek, R.3
  • 32
    • 0037149981 scopus 로고    scopus 로고
    • An analysis of MCNP cross sections and tally methods for low-energy photon emitters
    • J. J. DeMarco, R. E. Wallace, and K. Boedeker, "An analysis of MCNP cross sections and tally methods for low-energy photon emitters," Phys. Med. Biol. 47, 1321-1332 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1321-1332
    • DeMarco, J.J.1    Wallace, R.E.2    Boedeker, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.