-
1
-
-
2442544699
-
Urinary tract biomaterials
-
Beiko D.T., Knudsen B.E., Watterson J.D., Cadieux P.A., Reid G., and Denstedt J.D. Urinary tract biomaterials. J Urol 171 (2004) 2438
-
(2004)
J Urol
, vol.171
, pp. 2438
-
-
Beiko, D.T.1
Knudsen, B.E.2
Watterson, J.D.3
Cadieux, P.A.4
Reid, G.5
Denstedt, J.D.6
-
2
-
-
3042826214
-
Update on ureteral stents
-
Lam J.S., and Gupta M. Update on ureteral stents. Urology 64 (2004) 9
-
(2004)
Urology
, vol.64
, pp. 9
-
-
Lam, J.S.1
Gupta, M.2
-
3
-
-
0032765496
-
Mechanism of ureteral stent flow: a comparative in vivo study
-
Brewer A.V., Elbahnasy A.M., Bercowsky E., Maxwell K.L., Shalhav A.L., Kahn S.A., et al. Mechanism of ureteral stent flow: a comparative in vivo study. J Endurol 13 (1999) 269
-
(1999)
J Endurol
, vol.13
, pp. 269
-
-
Brewer, A.V.1
Elbahnasy, A.M.2
Bercowsky, E.3
Maxwell, K.L.4
Shalhav, A.L.5
Kahn, S.A.6
-
4
-
-
20744447795
-
Technology inside: novel ureteral stent materials and designs
-
Chew B.H., and Denstedt J.D. Technology inside: novel ureteral stent materials and designs. Nature Clin Prac Urol 1 (2004) 44
-
(2004)
Nature Clin Prac Urol
, vol.1
, pp. 44
-
-
Chew, B.H.1
Denstedt, J.D.2
-
5
-
-
27744567632
-
Ureteral obstruction and stents: still a difficult problem for patients and urologists alike
-
Russo P. Ureteral obstruction and stents: still a difficult problem for patients and urologists alike. J Urol 174 (2005) 2088
-
(2005)
J Urol
, vol.174
, pp. 2088
-
-
Russo, P.1
-
6
-
-
0037434515
-
Infection control: a problem for patient safety
-
Burke J.P. Infection control: a problem for patient safety. N Engl J Med 348 (2003) 651
-
(2003)
N Engl J Med
, vol.348
, pp. 651
-
-
Burke, J.P.1
-
7
-
-
0348230977
-
The application of biofilm science to the study and control of chronic bacterial infections
-
Costerton W., Veeh R., Shirtliff M., Pasmore M., Post C., and Ehrlich G. The application of biofilm science to the study and control of chronic bacterial infections. J Clin Invest 112 (2003) 1466
-
(2003)
J Clin Invest
, vol.112
, pp. 1466
-
-
Costerton, W.1
Veeh, R.2
Shirtliff, M.3
Pasmore, M.4
Post, C.5
Ehrlich, G.6
-
8
-
-
0030222114
-
Comparative assessment of ureteral stent biomineral encrustation
-
Tunney M.M., Keane P.F., Jones D.S., and Gorman S.P. Comparative assessment of ureteral stent biomineral encrustation. Biomaterials 17 (1996) 1541
-
(1996)
Biomaterials
, vol.17
, pp. 1541
-
-
Tunney, M.M.1
Keane, P.F.2
Jones, D.S.3
Gorman, S.P.4
-
9
-
-
0037364239
-
Indwelling ureteral stents: evaluation of symptoms, quality of life and utility
-
Joshi H.B., Stainthorpe A., MacDonagh R.P., Keely F.X., and Timoney A.G. Indwelling ureteral stents: evaluation of symptoms, quality of life and utility. J Urol 169 (2003) 1065
-
(2003)
J Urol
, vol.169
, pp. 1065
-
-
Joshi, H.B.1
Stainthorpe, A.2
MacDonagh, R.P.3
Keely, F.X.4
Timoney, A.G.5
-
11
-
-
16844384049
-
Encrustation of biomaterials in the urinary tract
-
Shaw G.L., Choong S.K., and Fry C. Encrustation of biomaterials in the urinary tract. Urol Res 33 (2005) 17
-
(2005)
Urol Res
, vol.33
, pp. 17
-
-
Shaw, G.L.1
Choong, S.K.2
Fry, C.3
-
12
-
-
0042624725
-
Characteristics of bacterial colonization and urinary tract infection after indwelling of double-J ureteral stent
-
Paick S.H., Park H.K., SJ O.H., and Kim H.H. Characteristics of bacterial colonization and urinary tract infection after indwelling of double-J ureteral stent. Urology 62 (2003) 214
-
(2003)
Urology
, vol.62
, pp. 214
-
-
Paick, S.H.1
Park, H.K.2
SJ, O.H.3
Kim, H.H.4
-
13
-
-
0028332150
-
Characterization of biofilm and encrustation on ureteric stents in vivo
-
Keane P.F., Bonner M.C., Johnston S.R., Zafar A., and Gorman S.P. Characterization of biofilm and encrustation on ureteric stents in vivo. Br J Urol 73 (1994) 687
-
(1994)
Br J Urol
, vol.73
, pp. 687
-
-
Keane, P.F.1
Bonner, M.C.2
Johnston, S.R.3
Zafar, A.4
Gorman, S.P.5
-
14
-
-
0037467478
-
Control of encrustation and blockage of Foley catheters
-
Stickler J.D., Jones G.L., and Russel A.D. Control of encrustation and blockage of Foley catheters. Lancet 351 (2003) 1435
-
(2003)
Lancet
, vol.351
, pp. 1435
-
-
Stickler, J.D.1
Jones, G.L.2
Russel, A.D.3
-
15
-
-
0034626083
-
Ureteric stents, far from ideal
-
Tolley D. Ureteric stents, far from ideal. Lancet 356 (2000) 872
-
(2000)
Lancet
, vol.356
, pp. 872
-
-
Tolley, D.1
-
16
-
-
0037309820
-
Diamond-like carbon coatings as biocompatible materials-an overview
-
Grill A. Diamond-like carbon coatings as biocompatible materials-an overview. Diam Relat Mater 12 (2003) 166
-
(2003)
Diam Relat Mater
, vol.12
, pp. 166
-
-
Grill, A.1
-
17
-
-
0037852937
-
A review of modified DLC coatings for biological applications
-
Hauert R. A review of modified DLC coatings for biological applications. Diam Relat Mater 12 (2003) 583
-
(2003)
Diam Relat Mater
, vol.12
, pp. 583
-
-
Hauert, R.1
-
18
-
-
24644496168
-
The ultrasmoothness of diamond-like carbon surfaces
-
Moseler M., Gumbsch P., Casiraghi C., Ferrari A.C., and Robertson J. The ultrasmoothness of diamond-like carbon surfaces. Science 306 (2005) 1545
-
(2005)
Science
, vol.306
, pp. 1545
-
-
Moseler, M.1
Gumbsch, P.2
Casiraghi, C.3
Ferrari, A.C.4
Robertson, J.5
-
19
-
-
0037165927
-
Diamond-like amorphous carbon
-
Robertson J. Diamond-like amorphous carbon. Mat Sci Eng R 37 (2002) 129
-
(2002)
Mat Sci Eng R
, vol.37
, pp. 129
-
-
Robertson, J.1
-
20
-
-
0037431766
-
New ways to stop biofilm infections
-
Stewart P.R. New ways to stop biofilm infections. Lancet 361 (2003) 97
-
(2003)
Lancet
, vol.361
, pp. 97
-
-
Stewart, P.R.1
|