Volumn 51, Issue 5, 2007, Pages 625-632

Compound A, formaldehyde and methanol concentrations during low-flow sevoflurane anaesthesia: Comparison of three carbon dioxide absorbers

Author keywords

Amsorb Plus ; Anaesthetics; Carbon dioxide absorbers; Compound A; Dr gersorb Free ; Formaldehyde; Low flow anaesthesia; Methanol; Sevoflurane; Soda lime

Indexed keywords

2,2 DIFLUORO 1 (TRIFLUOROMETHYL)VINYL FLUOROMETHYL ETHER; ABSORBENT; CARBON DIOXIDE; CISATRACURIUM; FENTANYL; FORMALDEHYDE; METHANOL; PROPOFOL; SEVOFLURANE; SODIUM CARBONATE; SUXAMETHONIUM; VECURONIUM;

EID: 34147116183     PISSN: 00015172     EISSN: 13996576     Source Type: Journal    
DOI: 10.1111/j.1399-6576.2007.01278.x     Document Type: Article
Times cited : (19)

References (27)
  • 1
    • 0026715577 scopus 로고
    • Reactions of sevoflurane and its degradation products with soda lime
    • Morio M, Fujii K, Satoh N et al. Reactions of sevoflurane and its degradation products with soda lime. Anesthesiology 1992; 77: 1155-64.
    • (1992) Anesthesiology , vol.77 , pp. 1155-1164
    • Morio, M.1    Fujii, K.2    Satoh, N.3
  • 2
    • 0036112442 scopus 로고    scopus 로고
    • Soda lime temperatures during low-flow sevoflurane anaesthesia and differences in deadspace
    • Luttropp HH, Johansson A. Soda lime temperatures during low-flow sevoflurane anaesthesia and differences in deadspace. Acta Anaesthesiol Scand 2002; 46: 500-5.
    • (2002) Acta Anaesthesiol Scand , vol.46 , pp. 500-505
    • Luttropp, H.H.1    Johansson, A.2
  • 5
    • 34147152195 scopus 로고    scopus 로고
    • Carbon dioxide absorption during anaesthesia. Scientific principles of anaesthesia
    • January
    • Murray J, Bedi A. Carbon dioxide absorption during anaesthesia. Scientific principles of anaesthesia. Royal College of Anaesthetists Newsletter 2000; January: 50.
    • (2000) Royal College of Anaesthetists Newsletter , pp. 50
    • Murray, J.1    Bedi, A.2
  • 6
    • 27544456307 scopus 로고    scopus 로고
    • Cost-effectiveness of basal flow sevoflurane anaesthesia using the Komesaroff vaporizer inside the circle system
    • Nandalan SP, Eltringham Q, Fan QW. Cost-effectiveness of basal flow sevoflurane anaesthesia using the Komesaroff vaporizer inside the circle system. Anaesth Intensive Care 2005; 33: 609-15.
    • (2005) Anaesth Intensive Care , vol.33 , pp. 609-615
    • Nandalan, S.P.1    Eltringham, Q.2    Fan, Q.W.3
  • 7
    • 0029134611 scopus 로고
    • Closed circuit anaesthesia. The climatic environment: Preservation of heat and moisture
    • Novelli GP, Di Filippo A. Closed circuit anaesthesia. The climatic environment: preservation of heat and moisture. Appl Cardiopulmon Pathophysiol 1995; 5 (S2): 63-8.
    • (1995) Appl Cardiopulmon Pathophysiol , vol.5 , Issue.S2 , pp. 63-68
    • Novelli, G.P.1    Di Filippo, A.2
  • 8
    • 0032906425 scopus 로고    scopus 로고
    • Dry soda lime markedly degrades sevoflurane during simulated inhalation induction
    • Funk W, Gruber M, Wild K, Hobbhahn J. Dry soda lime markedly degrades sevoflurane during simulated inhalation induction. Br J Anaesth 1999; 82: 193-8.
    • (1999) Br J Anaesth , vol.82 , pp. 193-198
    • Funk, W.1    Gruber, M.2    Wild, K.3    Hobbhahn, J.4
  • 9
    • 0029166906 scopus 로고
    • Factors affecting the concentration of Compound A resulting from the degradation of sevoflurane by soda lime and Baralyme in a standard anesthetic circuit
    • Fang ZX. Eger EI II. Factors affecting the concentration of Compound A resulting from the degradation of sevoflurane by soda lime and Baralyme in a standard anesthetic circuit. Anesth Analg 1995; 81: 564-8.
    • (1995) Anesth Analg , vol.81 , pp. 564-568
    • Fang, Z.X.1    Eger II, E.I.2
  • 11
    • 0034982062 scopus 로고    scopus 로고
    • Lack of degradation of sevoflurane by new carbon dioxide absorbent in humans
    • Mchaourab A, Arain S, Ebert T. Lack of degradation of sevoflurane by new carbon dioxide absorbent in humans. Anesthesiology 2001; 94: 1007-9.
    • (2001) Anesthesiology , vol.94 , pp. 1007-1009
    • Mchaourab, A.1    Arain, S.2    Ebert, T.3
  • 12
    • 0036896802 scopus 로고    scopus 로고
    • No compound A formation with Superia during minimal-flow sevoflurane anesthesia: A comparison with Sofnolime
    • Bouche M, Versichelen L, Struys M et al. No compound A formation with Superia during minimal-flow sevoflurane anesthesia: a comparison with Sofnolime. Anesth Analg 2002; 95: 1680-5.
    • (2002) Anesth Analg , vol.95 , pp. 1680-1685
    • Bouche, M.1    Versichelen, L.2    Struys, M.3
  • 14
    • 0028228934 scopus 로고
    • Inhibition of volatile sevoflurane degradation product formation in an anesthesia circuit by a reduction in soda lime temperature
    • Ruzicka JA, Hidalgo JC, Tinker JH, Baker MT. Inhibition of volatile sevoflurane degradation product formation in an anesthesia circuit by a reduction in soda lime temperature. Anesthesiology 1994; 81: 238-44.
    • (1994) Anesthesiology , vol.81 , pp. 238-244
    • Ruzicka, J.A.1    Hidalgo, J.C.2    Tinker, J.H.3    Baker, M.T.4
  • 15
    • 0031962704 scopus 로고    scopus 로고
    • Effects of the water content of soda lime on compound A concentration in the anesthesia circuit in sevoflurane anesthesia
    • Bito H, Ikeuchi Y, Ikeda K. Effects of the water content of soda lime on compound A concentration in the anesthesia circuit in sevoflurane anesthesia. Anesthesiology 1998; 88: 66-71.
    • (1998) Anesthesiology , vol.88 , pp. 66-71
    • Bito, H.1    Ikeuchi, Y.2    Ikeda, K.3
  • 18
    • 28044472967 scopus 로고    scopus 로고
    • Influence of sevoflurane on the metabolism and renal effects of compound A in rats
    • Kharasch E, Schroeder J, Sheffels P, Liggitt D. Influence of sevoflurane on the metabolism and renal effects of compound A in rats. Anesthesiology 2005; 103: 1183-8.
    • (2005) Anesthesiology , vol.103 , pp. 1183-1188
    • Kharasch, E.1    Schroeder, J.2    Sheffels, P.3    Liggitt, D.4
  • 19
    • 0031911559 scopus 로고    scopus 로고
    • Iyer RA, Frink EJ, Ebert TJ, Anders MW. Cysteine conjugate b-lyase-dependent metabolism of Compound A (2-[fluoromethoxy]-1,1,3,3,3- pentafluoro-1-propene) in human subjects anesthetized with sevoflurane and in rats given Compound A. Anesthesiology 1998; 88: 611-8.
    • Iyer RA, Frink EJ, Ebert TJ, Anders MW. Cysteine conjugate b-lyase-dependent metabolism of Compound A (2-[fluoromethoxy]-1,1,3,3,3- pentafluoro-1-propene) in human subjects anesthetized with sevoflurane and in rats given Compound A. Anesthesiology 1998; 88: 611-8.
  • 20
    • 0030457616 scopus 로고    scopus 로고
    • Cysteine conjugate β-lyase-dependent biotransformation of the cysteine S-conjugates of the sevoflurane degradation product Compound A in human, nonhuman primate, and rat renal cytosol and mitochondria
    • Iyer RA, Anders MW. Cysteine conjugate β-lyase-dependent biotransformation of the cysteine S-conjugates of the sevoflurane degradation product Compound A in human, nonhuman primate, and rat renal cytosol and mitochondria. Anesthesiology 1996; 85: 1454-61.
    • (1996) Anesthesiology , vol.85 , pp. 1454-1461
    • Iyer, R.A.1    Anders, M.W.2
  • 21
    • 0033934433 scopus 로고    scopus 로고
    • Carbon dioxide absorbers containing potassium hydroxide produce much larger concentrations of Compound A from sevoflurane in clinical practice
    • Yamakage M, Yamada S, Chen X, Iwasaki S, Tsujiguchi N, Namiki A. Carbon dioxide absorbers containing potassium hydroxide produce much larger concentrations of Compound A from sevoflurane in clinical practice. Anesth Analg 2000; 91: 220-4.
    • (2000) Anesth Analg , vol.91 , pp. 220-224
    • Yamakage, M.1    Yamada, S.2    Chen, X.3    Iwasaki, S.4    Tsujiguchi, N.5    Namiki, A.6
  • 22
    • 0033854898 scopus 로고    scopus 로고
    • Compound A concentrations during low flow sevoflurane anaesthesia correlate directly with the concentration of monovalent bases in carbon dioxide absorbers
    • Higuchi H, Adachi Y, Arimura S, Kanno M, Satoh T. Compound A concentrations during low flow sevoflurane anaesthesia correlate directly with the concentration of monovalent bases in carbon dioxide absorbers. Anesth Analg 2000; 91: 434-9.
    • (2000) Anesth Analg , vol.91 , pp. 434-439
    • Higuchi, H.1    Adachi, Y.2    Arimura, S.3    Kanno, M.4    Satoh, T.5
  • 23
    • 0037301129 scopus 로고    scopus 로고
    • Compound A concentration in the circle absorber system during low-flow sevoflurane anesthesia: Comparison of Drägersorb Free, Amsorb and Sodasorb II
    • Kobayashi S, Bito H, Obata Y, Katoh T, Sato S. Compound A concentration in the circle absorber system during low-flow sevoflurane anesthesia: comparison of Drägersorb Free, Amsorb and Sodasorb II. J Clin Anesth 2003; 15: 33-7.
    • (2003) J Clin Anesth , vol.15 , pp. 33-37
    • Kobayashi, S.1    Bito, H.2    Obata, Y.3    Katoh, T.4    Sato, S.5
  • 25
    • 16844369448 scopus 로고    scopus 로고
    • US Environmental Protection Agency, Washington: US Environmental Protection Agency Indoor Air Publications
    • US Environmental Protection Agency. An Update on Formaldehyde - 1997 Revision. Washington: US Environmental Protection Agency Indoor Air Publications, 1997.
    • (1997) An Update on Formaldehyde - 1997 Revision


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.