메뉴 건너뛰기




Volumn 14, Issue 4, 2006, Pages 537-544

MR Imaging of the Female Pelvis at 3T

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFACT; DIELECTRIC CONSTANT; FEMALE; HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PELVIS; PELVIS RADIOGRAPHY; RADIOFREQUENCY; REVIEW; SIGNAL NOISE RATIO;

EID: 34047273188     PISSN: 10649689     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mric.2007.01.008     Document Type: Review
Times cited : (18)

References (28)
  • 1
    • 33748440818 scopus 로고    scopus 로고
    • Abdominal magnetic resonance imaging at 3.0T: problem or a promise for the future?
    • Hussain S.M., Wielopolski P.A., and Martin D.R. Abdominal magnetic resonance imaging at 3.0T: problem or a promise for the future?. Top Magn Reson Imaging 16 (2005) 325-335
    • (2005) Top Magn Reson Imaging , vol.16 , pp. 325-335
    • Hussain, S.M.1    Wielopolski, P.A.2    Martin, D.R.3
  • 2
    • 0028970394 scopus 로고
    • Imaging of the ovary and adnexa: clinical issues and applications of MR imaging
    • Outwater E.K., and Dunton C.J. Imaging of the ovary and adnexa: clinical issues and applications of MR imaging. Radiology 194 (1995) 1-18
    • (1995) Radiology , vol.194 , pp. 1-18
    • Outwater, E.K.1    Dunton, C.J.2
  • 6
    • 0034972627 scopus 로고    scopus 로고
    • Magnetic resonance angiography at 3.0 Tesla: initial clinical experience
    • Campeau N.G., Huston J., Bernstein M.A., et al. Magnetic resonance angiography at 3.0 Tesla: initial clinical experience. Top Magn Reson Imaging 12 (2001) 183-204
    • (2001) Top Magn Reson Imaging , vol.12 , pp. 183-204
    • Campeau, N.G.1    Huston, J.2    Bernstein, M.A.3
  • 7
    • 0242268584 scopus 로고    scopus 로고
    • High field human imaging
    • Norris D.G. High field human imaging. J Magn Reson Imaging 18 (2003) 519-529
    • (2003) J Magn Reson Imaging , vol.18 , pp. 519-529
    • Norris, D.G.1
  • 8
    • 34047246030 scopus 로고    scopus 로고
    • Watkins RD, Schenk JF, Rohling KW, et al. Whole body RF coil for 3 tesla MRI systems. Proceeding of the International Society of Magnetic Resonance in Medicine 2001;9:1123.
  • 9
    • 34047254357 scopus 로고    scopus 로고
    • Roberts S, Freeman A, Murphy P, et al. High definition whole body imaging at 3tesla. Proceeding of the International Society of Magnetic Resonance in Medicine 2001;9:2013.
  • 10
    • 20344407028 scopus 로고    scopus 로고
    • Approach to abdominal imaging at 1.5 tesla and optimization at 3 tesla
    • Martin D.R., Friel H.T., Danrad R., et al. Approach to abdominal imaging at 1.5 tesla and optimization at 3 tesla. Magn Reson Imaging Clin N Am 13 (2005) 241-254
    • (2005) Magn Reson Imaging Clin N Am , vol.13 , pp. 241-254
    • Martin, D.R.1    Friel, H.T.2    Danrad, R.3
  • 12
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radio-frequency coil arrays
    • Sodickson D.K., and Manning W.J. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radio-frequency coil arrays. Magn Reson Med 38 (1997) 591-603
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 14
    • 0036263907 scopus 로고    scopus 로고
    • Generalized auto-calibrating partially parallel acquisition (GRAPPA)
    • Griswold M.A., Jakob P.M., Heidemann R.M., et al. Generalized auto-calibrating partially parallel acquisition (GRAPPA). Magn Reson Med 47 (2002) 1202-1210
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 15
    • 0023870882 scopus 로고
    • Fast MRI data acquisition using multiple detectors
    • Hutchinson M., and Raff U. Fast MRI data acquisition using multiple detectors. Magn Reson Med 6 (1988) 87-91
    • (1988) Magn Reson Med , vol.6 , pp. 87-91
    • Hutchinson, M.1    Raff, U.2
  • 16
    • 0036223150 scopus 로고    scopus 로고
    • Estimation of heat transfer and temperature rise in partial-body regions during MR procedures: an analytical approach with respect to safety considerations
    • Brix B., Seebass M., Hellwig G., et al. Estimation of heat transfer and temperature rise in partial-body regions during MR procedures: an analytical approach with respect to safety considerations. Magn Reson Imaging 20 (2002) 65-76
    • (2002) Magn Reson Imaging , vol.20 , pp. 65-76
    • Brix, B.1    Seebass, M.2    Hellwig, G.3
  • 18
    • 0037373303 scopus 로고    scopus 로고
    • Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transition between pseudo steady states (TRAPS)
    • Hennig J., Weigel M., and Scheffler K. Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transition between pseudo steady states (TRAPS). Magn Reson Med 49 (2003) 527-535
    • (2003) Magn Reson Med , vol.49 , pp. 527-535
    • Hennig, J.1    Weigel, M.2    Scheffler, K.3
  • 19
    • 0038101619 scopus 로고    scopus 로고
    • Increased diffusion sensitivity with hyperechoes
    • Frank L.R., Wong E.C., Liu T.T., et al. Increased diffusion sensitivity with hyperechoes. Magn Reson Med 49 (2003) 1096-1105
    • (2003) Magn Reson Med , vol.49 , pp. 1096-1105
    • Frank, L.R.1    Wong, E.C.2    Liu, T.T.3
  • 20
    • 34047248761 scopus 로고    scopus 로고
    • Busse RF, Zur Y, Body XL. Lower SAR yields improved coverage with VERSE and modulated angle refocusing trains. Proceeding of the International Society of Magnetic Resonance in Medicine 2003;11:206.
  • 21
    • 0038050726 scopus 로고    scopus 로고
    • Double inversion black-blood fast spin-echo imaging of the human heart: a comparison between 1.5T and 3.0T
    • Greenman R.L., Shirosky J.E., Mulkern R.V., et al. Double inversion black-blood fast spin-echo imaging of the human heart: a comparison between 1.5T and 3.0T. J Magn Reson Imaging 17 (2003) 648-655
    • (2003) J Magn Reson Imaging , vol.17 , pp. 648-655
    • Greenman, R.L.1    Shirosky, J.E.2    Mulkern, R.V.3
  • 22
    • 34047244244 scopus 로고    scopus 로고
    • Alsop D, Watkins RD, Greenman R, et al. In-vivo mapping of B1 uniformity produced by a whole body 3T RF coil. Proceeding of the International Society of Magnetic Resonance in Medicine 2001;9:1094.
  • 23
    • 0032726055 scopus 로고    scopus 로고
    • Dielectric resonance phenomena in ultra high field MRI
    • Kangarlu A., Baertlein B.A., Lee R., et al. Dielectric resonance phenomena in ultra high field MRI. J Comput Assist Tomogr 23 (1999) 821-831
    • (1999) J Comput Assist Tomogr , vol.23 , pp. 821-831
    • Kangarlu, A.1    Baertlein, B.A.2    Lee, R.3
  • 24
    • 14044266362 scopus 로고    scopus 로고
    • Can a single-shot black-blood T2-weighted spin-echo echo planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver?-an optimization and a feasibility study
    • Hussain S.M., De Becker J., Hop W.C.J., et al. Can a single-shot black-blood T2-weighted spin-echo echo planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver?-an optimization and a feasibility study. J Magn Reson Imaging 21 (2005) 219-229
    • (2005) J Magn Reson Imaging , vol.21 , pp. 219-229
    • Hussain, S.M.1    De Becker, J.2    Hop, W.C.J.3
  • 25
    • 0036119659 scopus 로고    scopus 로고
    • Magnetic resonance imaging contrast enhancement of brain tumors at 3 tesla versus 1.5 tesla
    • Nobauer-Huhmann I.M., Ba-Ssalamah A., Mlynarik V., et al. Magnetic resonance imaging contrast enhancement of brain tumors at 3 tesla versus 1.5 tesla. Invest Radiol 37 (2002) 114-119
    • (2002) Invest Radiol , vol.37 , pp. 114-119
    • Nobauer-Huhmann, I.M.1    Ba-Ssalamah, A.2    Mlynarik, V.3
  • 26
    • 33750366054 scopus 로고    scopus 로고
    • Female pelvis: MR imaging at 3.0 T with sensitivity encoding and flip-angle sweep technique
    • Morakkabati-Spitz N., Schild H.H., Kuhl C.K., et al. Female pelvis: MR imaging at 3.0 T with sensitivity encoding and flip-angle sweep technique. Radiology 241 (2006) 538-545
    • (2006) Radiology , vol.241 , pp. 538-545
    • Morakkabati-Spitz, N.1    Schild, H.H.2    Kuhl, C.K.3
  • 27
    • 34047248255 scopus 로고    scopus 로고
    • Van den Bos IC, Hussain SM, Krestin GP, et al. Variable-rate-selective-excitation (VERSE) RF pulses with fat-suppressed T2-weighted fast spin-echo imaging for breath-hold liver imaging at 3.0T. ESMRMB, 23rd Annual Meeting, Warschau, Poland. Proceeding of the European Society of Magnetic Resonance in Medicine and Biology 2006;108.
  • 28
    • 34047250852 scopus 로고    scopus 로고
    • Van den Bos IC, Hussain SM, Wielopolski PA. Imaging of the liver at 3.0T: optimization of breath-hold, volumetric fat-suppressed fast spin-echo and diffusion-weighted black-blood echo-planar imaging. ISMRM, 14th Scientific Meeting and Exhibition, Seattle (WA). Proceeding of the International Society of Magnetic Resonance in Medicine 2006;447.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.