메뉴 건너뛰기




Volumn 48, Issue 3, 2007, Pages 1156-1163

Effect of glaucomatous damage on repeatability of confocal scanning laser ophthalmoscope, scanning laser polarimetry, and optical coherence tomography

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGE; ARTICLE; CONTROLLED STUDY; DISEASE SEVERITY; GLAUCOMA; HUMAN; LENS; MAJOR CLINICAL STUDY; NERVE FIBER; OPTIC NERVE; OPTICAL COHERENCE TOMOGRAPHY; POLARIMETRY; PRIORITY JOURNAL; SCANNING LASER OPHTHALMOSCOPE; TEST RETEST RELIABILITY; VISUAL ACUITY; VISUAL FIELD DEFECT; COMPARATIVE STUDY; DIAGNOSTIC IMAGING; FEMALE; INTRAOCULAR PRESSURE; LASER; MALE; METHODOLOGY; MIDDLE AGED; OPHTHALMOSCOPY; OPTIC DISK; OPTIC NERVE DISEASE; PATHOLOGY; PERIMETRY; REPRODUCIBILITY; RETINA GANGLION CELL; STANDARD; VISUAL DISORDER;

EID: 34047246672     PISSN: 01460404     EISSN: None     Source Type: Journal    
DOI: 10.1167/iovs.06-0921     Document Type: Article
Times cited : (68)

References (36)
  • 1
    • 0036022742 scopus 로고    scopus 로고
    • Variables affecting test-retest variability of Heidelberg Retina Tomograph II stereometric parameters
    • Sihota R, Gulati V, Agarwal HC, Saxena R, Sharma A, Pandey RM. Variables affecting test-retest variability of Heidelberg Retina Tomograph II stereometric parameters. J Glaucoma. 2002;11:321-328.
    • (2002) J Glaucoma , vol.11 , pp. 321-328
    • Sihota, R.1    Gulati, V.2    Agarwal, H.C.3    Saxena, R.4    Sharma, A.5    Pandey, R.M.6
  • 2
    • 27344454659 scopus 로고    scopus 로고
    • Factors affecting the test-retest variability of Heidelberg retina tomograph and Heidelberg retina tomograph II measurements
    • Strouthidis NG, White ET, Owen VM, Ho TA, Hammond CJ, Garway-Heath DF. Factors affecting the test-retest variability of Heidelberg retina tomograph and Heidelberg retina tomograph II measurements. Br J Ophthalmol. 2005;89:1427-1432.
    • (2005) Br J Ophthalmol , vol.89 , pp. 1427-1432
    • Strouthidis, N.G.1    White, E.T.2    Owen, V.M.3    Ho, T.A.4    Hammond, C.J.5    Garway-Heath, D.F.6
  • 3
    • 0031459317 scopus 로고    scopus 로고
    • Reproducibility of retardation measurements with the nerve fiber analyzer II
    • Zangwill L, Berry CA, Garden VS, Weinreb RN. Reproducibility of retardation measurements with the nerve fiber analyzer II. J Glaucoma. 1997;6:384-389.
    • (1997) J Glaucoma , vol.6 , pp. 384-389
    • Zangwill, L.1    Berry, C.A.2    Garden, V.S.3    Weinreb, R.N.4
  • 4
    • 12344316312 scopus 로고    scopus 로고
    • Intraobserver reproducibility of retinal nerve fiber layer measurements using scanning laser polarimetry and optical coherence tomography in normal and ocular hypertensive subjects
    • Lleó-Pérez A, Ortuno-Soto A, Rahhal MS, Martinez-Soriano F, Sanchis-Gimeno JA. Intraobserver reproducibility of retinal nerve fiber layer measurements using scanning laser polarimetry and optical coherence tomography in normal and ocular hypertensive subjects. Eur J Ophthalmol. 2004;14:523-530.
    • (2004) Eur J Ophthalmol , vol.14 , pp. 523-530
    • Lleó-Pérez, A.1    Ortuno-Soto, A.2    Rahhal, M.S.3    Martinez-Soriano, F.4    Sanchis-Gimeno, J.A.5
  • 5
    • 3042668265 scopus 로고    scopus 로고
    • Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT
    • Paunescu IA, Schuman JS, Price LL, et al. Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT. Invest Ophthalmol Vis Sci. 2004;45:1716-1724.
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 1716-1724
    • Paunescu, I.A.1    Schuman, J.S.2    Price, L.L.3
  • 7
    • 0346034748 scopus 로고    scopus 로고
    • Reproducibility of measuring retinal nerve fiber density: Comparison of optical coherence tomography with the nerve fiber analyzer and the Heidelberg retinal tomography device
    • in German
    • Klemm M, Rumberger E, Walter A, Richard G. Reproducibility of measuring retinal nerve fiber density: comparison of optical coherence tomography with the nerve fiber analyzer and the Heidelberg retinal tomography device (in German). Ophthalmologe. 2002;99:345-351.
    • (2002) Ophthalmologe , vol.99 , pp. 345-351
    • Klemm, M.1    Rumberger, E.2    Walter, A.3    Richard, G.4
  • 9
    • 0024399833 scopus 로고
    • Test-retest variability in glaucomatous visual fields
    • Heijl A, Lindgren A, Lindgren G. Test-retest variability in glaucomatous visual fields. Am J Ophthalmol. 1989;108:130-135.
    • (1989) Am J Ophthalmol , vol.108 , pp. 130-135
    • Heijl, A.1    Lindgren, A.2    Lindgren, G.3
  • 10
    • 0034055519 scopus 로고    scopus 로고
    • Technique for detecting serial topographic changes in the optic disc and peripapillary retina using scanning laser tomography
    • Chauhan BC, Blanchard JW, Hamilton DC, LeBlanc RP. Technique for detecting serial topographic changes in the optic disc and peripapillary retina using scanning laser tomography. Invest Ophthalmol Vis Sci. 2000;41:775-782.
    • (2000) Invest Ophthalmol Vis Sci , vol.41 , pp. 775-782
    • Chauhan, B.C.1    Blanchard, J.W.2    Hamilton, D.C.3    LeBlanc, R.P.4
  • 11
    • 0031867951 scopus 로고    scopus 로고
    • Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucoma
    • Bengtsson B, Heijl A. Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucoma. Act Ophthalmol Scand. 1998;76:268-272.
    • (1998) Act Ophthalmol Scand , vol.76 , pp. 268-272
    • Bengtsson, B.1    Heijl, A.2
  • 13
    • 0036206345 scopus 로고    scopus 로고
    • Optic nerve and retinal nerve fiber layer analyzers in glaucoma
    • Greenfield DS. Optic nerve and retinal nerve fiber layer analyzers in glaucoma. Curr Opin Ophthalmol. 2002;13:68-76.
    • (2002) Curr Opin Ophthalmol , vol.13 , pp. 68-76
    • Greenfield, D.S.1
  • 14
    • 0346729846 scopus 로고    scopus 로고
    • Optical coherence tomography to detect and manage retinal disease and glaucoma
    • Jaffe GJ, Caprioli J. Optical coherence tomography to detect and manage retinal disease and glaucoma. Am J Ophthalmol. 2004;137:156-169.
    • (2004) Am J Ophthalmol , vol.137 , pp. 156-169
    • Jaffe, G.J.1    Caprioli, J.2
  • 16
    • 0032779891 scopus 로고    scopus 로고
    • New technologies for diagnosing and monitoring glaucomatous optic neuropathy
    • Zangwill LM, Chang CF, Williams JM, Weinreb RN. New technologies for diagnosing and monitoring glaucomatous optic neuropathy. Optom Vis Sci. 1999;76:526-536.
    • (1999) Optom Vis Sci , vol.76 , pp. 526-536
    • Zangwill, L.M.1    Chang, C.F.2    Williams, J.M.3    Weinreb, R.N.4
  • 17
    • 0036310419 scopus 로고    scopus 로고
    • Measurement of the magnitude and axis of corneal polarization with scanning laser polarimetry
    • Weinreb RN, Bowd C, Greenfield DS, Zangwill LM. Measurement of the magnitude and axis of corneal polarization with scanning laser polarimetry. Arch Ophthalmol. 2002;120:901-906.
    • (2002) Arch Ophthalmol , vol.120 , pp. 901-906
    • Weinreb, R.N.1    Bowd, C.2    Greenfield, D.S.3    Zangwill, L.M.4
  • 18
    • 0036788666 scopus 로고    scopus 로고
    • Scanning laser polarimetry in monkey eyes using variable corneal polarization compensation
    • Weinreb RN, Bowd C, Zangwill LM. Scanning laser polarimetry in monkey eyes using variable corneal polarization compensation. J Glaucoma. 2002;11:378-384.
    • (2002) J Glaucoma , vol.11 , pp. 378-384
    • Weinreb, R.N.1    Bowd, C.2    Zangwill, L.M.3
  • 19
    • 4744356184 scopus 로고    scopus 로고
    • Diagnostic accuracy of the GDx VCC for glaucoma
    • Reus NJ, Lemij HG. Diagnostic accuracy of the GDx VCC for glaucoma. Ophthalmology. 2004;111:1860-1865.
    • (2004) Ophthalmology , vol.111 , pp. 1860-1865
    • Reus, N.J.1    Lemij, H.G.2
  • 20
    • 15044355050 scopus 로고    scopus 로고
    • Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation
    • Bagga H, Greenfield DS, Feuer WJ. Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation. Am J Ophthalmol. 2005;139:437-446.
    • (2005) Am J Ophthalmol , vol.139 , pp. 437-446
    • Bagga, H.1    Greenfield, D.S.2    Feuer, W.J.3
  • 21
    • 0032820712 scopus 로고    scopus 로고
    • The interpretation of optical coherence tomography images of the retina
    • Chauhan DS, Marshall J. The interpretation of optical coherence tomography images of the retina. Invest Ophthalmol Vis Sci. 1999;40:2332-2342.
    • (1999) Invest Ophthalmol Vis Sci , vol.40 , pp. 2332-2342
    • Chauhan, D.S.1    Marshall, J.2
  • 22
    • 0041842725 scopus 로고    scopus 로고
    • Racial differences in the association between optic disc topography and early glaucoma
    • Girkin CA, McGwin G Jr, McNeal SF, DeLeon-Ortega J. Racial differences in the association between optic disc topography and early glaucoma. Invest Ophthalmol Vis Sci. 2003;44:3382-3387.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 3382-3387
    • Girkin, C.A.1    McGwin Jr, G.2    McNeal, S.F.3    DeLeon-Ortega, J.4
  • 24
    • 0027173798 scopus 로고
    • The Lens Opacities Classification System III. The Longitudinal Study of Cataract Study Group
    • Chylack LT Jr, Wolfe JK, Singer DM, et al. The Lens Opacities Classification System III. The Longitudinal Study of Cataract Study Group. Arch Ophthalmol. 1993;111:831-836.
    • (1993) Arch Ophthalmol , vol.111 , pp. 831-836
    • Chylack Jr, L.T.1    Wolfe, J.K.2    Singer, D.M.3
  • 25
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135-160.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 26
    • 85007744242 scopus 로고    scopus 로고
    • Transformations, means, and confidence intervals
    • Bland JM, Altman DG. Transformations, means, and confidence intervals. BMJ. 1996;312:1079.
    • (1996) BMJ , vol.312 , pp. 1079
    • Bland, J.M.1    Altman, D.G.2
  • 27
    • 85007669243 scopus 로고    scopus 로고
    • The use of transformation when comparing two means
    • Bland JM, Altman DG. The use of transformation when comparing two means. BMJ. 1996;312:1153.
    • (1996) BMJ , vol.312 , pp. 1153
    • Bland, J.M.1    Altman, D.G.2
  • 28
    • 85007685344 scopus 로고    scopus 로고
    • Transforming data
    • Bland JM, Altman DG. Transforming data. BMJ. 1996;312:770.
    • (1996) BMJ , vol.312 , pp. 770
    • Bland, J.M.1    Altman, D.G.2
  • 29
    • 0030017818 scopus 로고    scopus 로고
    • Measurement error proportional to the mean
    • Bland JM, Altman DG. Measurement error proportional to the mean. BMJ. 1996;313:106.
    • (1996) BMJ , vol.313 , pp. 106
    • Bland, J.M.1    Altman, D.G.2
  • 30
    • 39349092667 scopus 로고    scopus 로고
    • Bland JM. Comparing within-subject variances in a study to compare two methods of measurement. Available at http://www-usersyorkacuk/~mb55/meas/ compsdhtm. April 22, 2001. Accessed May 6, 2006.
    • Bland JM. Comparing within-subject variances in a study to compare two methods of measurement. Available at http://www-usersyorkacuk/~mb55/meas/ compsdhtm. April 22, 2001. Accessed May 6, 2006.
  • 31
    • 39349113207 scopus 로고    scopus 로고
    • Optical Coherence Tomographer Model 3000. Dublin, CA: Carl Zeiss Meditec, Inc.; Revision A1/02.
    • Optical Coherence Tomographer Model 3000. Dublin, CA: Carl Zeiss Meditec, Inc.; Revision A1/02.
  • 32
    • 39349104828 scopus 로고    scopus 로고
    • Ver. 5.1. Dublin, CA: Carl Zeiss Meditec, Inc
    • GDx VCC Operation Manual. Ver. 5.1. Dublin, CA: Carl Zeiss Meditec, Inc.
    • GDx VCC Operation Manual
  • 33
    • 33646785046 scopus 로고    scopus 로고
    • Test-retest variability in structural and functional parameters of glaucoma damage in the glaucoma imaging longitudinal study
    • Jampel HD, Vitale S, Ding Y, et al. Test-retest variability in structural and functional parameters of glaucoma damage in the glaucoma imaging longitudinal study. J Glaucoma. 2006;15:152-157.
    • (2006) J Glaucoma , vol.15 , pp. 152-157
    • Jampel, H.D.1    Vitale, S.2    Ding, Y.3
  • 34
    • 0033511432 scopus 로고    scopus 로고
    • Reversal of optic disc cupping after glaucoma surgery analyzed with a scanning laser tomograph
    • Lesk MR, Spaeth GL, Azuara-Blanco A, et al. Reversal of optic disc cupping after glaucoma surgery analyzed with a scanning laser tomograph. Ophthalmology. 1999;106:1013-1018.
    • (1999) Ophthalmology , vol.106 , pp. 1013-1018
    • Lesk, M.R.1    Spaeth, G.L.2    Azuara-Blanco, A.3
  • 35
    • 0033278358 scopus 로고    scopus 로고
    • Lee BL, Zangwill L, Weinreb RN. Change in optic disc topography associated with diurnal variation in intraocular pressure. J Glaucoma. 1999;8:221-223.
    • Lee BL, Zangwill L, Weinreb RN. Change in optic disc topography associated with diurnal variation in intraocular pressure. J Glaucoma. 1999;8:221-223.
  • 36
    • 0033795418 scopus 로고    scopus 로고
    • Optic disk topography after medical treatment to reduce intraocular pressure
    • Bowd C, Weinreb RN, Lee B, Emdadi A, Zangwill LM. Optic disk topography after medical treatment to reduce intraocular pressure. Am J Ophthalmol. 2000;130:280-286.
    • (2000) Am J Ophthalmol , vol.130 , pp. 280-286
    • Bowd, C.1    Weinreb, R.N.2    Lee, B.3    Emdadi, A.4    Zangwill, L.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.