메뉴 건너뛰기




Volumn 123, Issue 1, 2007, Pages 384-390

Glucose biosensor with a hydrophilic polyurethane (HPU) blended with polyvinyl alcohol/vinyl butyral copolymer (PVAB) outer membrane

Author keywords

Biosensor; Continuous monitoring; Glucose permeability; Outer membrane; Oxygen permeability

Indexed keywords

GAS PERMEABILITY; GLUCOSE; MONITORING; POLYMER BLENDS; POLYMERIC MEMBRANES; POLYURETHANES; POLYVINYL ALCOHOLS;

EID: 33947652664     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2006.08.042     Document Type: Article
Times cited : (43)

References (41)
  • 1
    • 0029764898 scopus 로고    scopus 로고
    • One step fabrication of a bienzyme glucose sensor based on glucose oxidase and peroxidase immobilized onto a poly(pyrrole) modified glassy carbon electrode
    • De Benedetto G.E., Palmisano F., and Zambonin P.G. One step fabrication of a bienzyme glucose sensor based on glucose oxidase and peroxidase immobilized onto a poly(pyrrole) modified glassy carbon electrode. Biosens. Bioelectron. 11 (1996) 1001
    • (1996) Biosens. Bioelectron. , vol.11 , pp. 1001
    • De Benedetto, G.E.1    Palmisano, F.2    Zambonin, P.G.3
  • 2
    • 0029293082 scopus 로고
    • An interfering factor in the glucose oxidase sensing system with polypyrrole/glucose oxidase membrane
    • Kojima K., Nasu H., Shimomura M., and Miyauchi S. An interfering factor in the glucose oxidase sensing system with polypyrrole/glucose oxidase membrane. Synth. Met. 71 (1995) 2245
    • (1995) Synth. Met. , vol.71 , pp. 2245
    • Kojima, K.1    Nasu, H.2    Shimomura, M.3    Miyauchi, S.4
  • 3
    • 0028203031 scopus 로고
    • Effect of flavin coenzymes on current response for glucose at glucose oxidase/polypyrrole modified electrodes
    • Kitani A., Kasyu N., and Sasaki K. Effect of flavin coenzymes on current response for glucose at glucose oxidase/polypyrrole modified electrodes. Electrochim. Acta 39 (1994) 7
    • (1994) Electrochim. Acta , vol.39 , pp. 7
    • Kitani, A.1    Kasyu, N.2    Sasaki, K.3
  • 4
    • 0002371808 scopus 로고
    • A theoretical model for amperometric glucose sensor using polypyrrole as the immobilization matrix
    • Marchesiello M., and Geniès E. A theoretical model for amperometric glucose sensor using polypyrrole as the immobilization matrix. J. Electroanal. Chem. 358 (1993) 35
    • (1993) J. Electroanal. Chem. , vol.358 , pp. 35
    • Marchesiello, M.1    Geniès, E.2
  • 5
    • 0030679208 scopus 로고    scopus 로고
    • Investigation of the origin of the glucose response in a glucose oxidase/polyaniline system
    • Nigel G., Skinner, Elizabeth A.H., and Hall. Investigation of the origin of the glucose response in a glucose oxidase/polyaniline system. J. Electroanal. Chem. 420 (1997) 179
    • (1997) J. Electroanal. Chem. , vol.420 , pp. 179
    • Nigel, G.1    Skinner2    Elizabeth, A.H.3    Hall4
  • 6
    • 0002747207 scopus 로고
    • Electron transfer on an electrode of glucose oxidase immobilized in polyaniline
    • Lu S., Li C., Zhang D., Zhang Y., Mo Z., Cai Q., and Zhu A. Electron transfer on an electrode of glucose oxidase immobilized in polyaniline. J. Electroanal. Chem. 364 (1994) 31
    • (1994) J. Electroanal. Chem. , vol.364 , pp. 31
    • Lu, S.1    Li, C.2    Zhang, D.3    Zhang, Y.4    Mo, Z.5    Cai, Q.6    Zhu, A.7
  • 7
    • 44049110752 scopus 로고
    • Bioelectrochemical response of the polyaniline uricase electrode
    • Mu S., Kan J., and Zhou J. Bioelectrochemical response of the polyaniline uricase electrode. J. Electroanal. Chem. 334 (1992) 121
    • (1992) J. Electroanal. Chem. , vol.334 , pp. 121
    • Mu, S.1    Kan, J.2    Zhou, J.3
  • 9
    • 0033689540 scopus 로고    scopus 로고
    • Properties of glucose sensor based on the immobilization of glucose oxidase in N-substituted polypyrrole film
    • Yasuzawa M., Nieda T., Hirano T., and Kunugi A. Properties of glucose sensor based on the immobilization of glucose oxidase in N-substituted polypyrrole film. Sens. Actuators B 66 (2000) 77
    • (2000) Sens. Actuators B , vol.66 , pp. 77
    • Yasuzawa, M.1    Nieda, T.2    Hirano, T.3    Kunugi, A.4
  • 10
    • 0035935310 scopus 로고    scopus 로고
    • Polyaniline-polyisoprene composite film based glucose biosensor with highly permselectivity
    • Xue H., Shen Z., and Li Y. Polyaniline-polyisoprene composite film based glucose biosensor with highly permselectivity. Synth. Met. 124 (2001) 345
    • (2001) Synth. Met. , vol.124 , pp. 345
    • Xue, H.1    Shen, Z.2    Li, Y.3
  • 11
    • 0029058443 scopus 로고
    • Development of amperometric biosensors based on the immobilization of enzymes in polymer films electrogenerated from a series of amphiphilic pyrrole derivatives
    • Coche-Guerente L., Cosnier S., Innocent C., and Mailley P. Development of amperometric biosensors based on the immobilization of enzymes in polymer films electrogenerated from a series of amphiphilic pyrrole derivatives. Anal. Chim. Acta 311 (1995) 23
    • (1995) Anal. Chim. Acta , vol.311 , pp. 23
    • Coche-Guerente, L.1    Cosnier, S.2    Innocent, C.3    Mailley, P.4
  • 12
    • 0036883708 scopus 로고    scopus 로고
    • Glucose microbiosensor based on alumina sol-gel matrix/electropolymerized composite membrane
    • Chen X., Hu Y., and Wilson G.S. Glucose microbiosensor based on alumina sol-gel matrix/electropolymerized composite membrane. Biosens. Bioelectron. 17 (2002) 1005
    • (2002) Biosens. Bioelectron. , vol.17 , pp. 1005
    • Chen, X.1    Hu, Y.2    Wilson, G.S.3
  • 13
    • 0028927095 scopus 로고
    • Evaluation of amperometric glucose biosensors based on co-immobilization of glucose oxidase with an osmium redox polymer in electrochemically generated polyphenol films
    • Pravda M., Jungar C.M., Iwuoha E.I., Smyth M.R., Vytras K., and Ivaska A. Evaluation of amperometric glucose biosensors based on co-immobilization of glucose oxidase with an osmium redox polymer in electrochemically generated polyphenol films. Anal. Chim. Acta 304 (1995) 127
    • (1995) Anal. Chim. Acta , vol.304 , pp. 127
    • Pravda, M.1    Jungar, C.M.2    Iwuoha, E.I.3    Smyth, M.R.4    Vytras, K.5    Ivaska, A.6
  • 14
    • 0000953523 scopus 로고
    • Characterization of glucose oxidase-modified poly(phenylenediamine)-coated electrodes in vitro and in vivo: homogeneous interference by ascorbic acid in hydrogen peroxide detection
    • Lowry J.P., McAteer K., Atrash S.S.E., Duff A., and O'Neil R.D. Characterization of glucose oxidase-modified poly(phenylenediamine)-coated electrodes in vitro and in vivo: homogeneous interference by ascorbic acid in hydrogen peroxide detection. Anal. Chem. 66 (1994) 1754
    • (1994) Anal. Chem. , vol.66 , pp. 1754
    • Lowry, J.P.1    McAteer, K.2    Atrash, S.S.E.3    Duff, A.4    O'Neil, R.D.5
  • 15
    • 0028472185 scopus 로고
    • Online measurement of brain glutamate with an enzyme/polymer coated tubular electrode
    • Berners M.O.M., Boutelle M.G., and Fillenz M. Online measurement of brain glutamate with an enzyme/polymer coated tubular electrode. Anal. Chem. 66 (1994) 2017
    • (1994) Anal. Chem. , vol.66 , pp. 2017
    • Berners, M.O.M.1    Boutelle, M.G.2    Fillenz, M.3
  • 16
    • 0034781821 scopus 로고    scopus 로고
    • Reproducible fabrication of miniaturized glucose biosensors: preparations of sensing membranes for continuous monitoring
    • Chung T.D., Jeong R., Kang S.K., and Kim H.C. Reproducible fabrication of miniaturized glucose biosensors: preparations of sensing membranes for continuous monitoring. Biosens. Bioelectron. 16 (2001) 1079
    • (2001) Biosens. Bioelectron. , vol.16 , pp. 1079
    • Chung, T.D.1    Jeong, R.2    Kang, S.K.3    Kim, H.C.4
  • 17
    • 0029256699 scopus 로고
    • Galactose biosensors using composite polymers to prevent interferences
    • Manowitz P., Stoecker P.W., and Yacynych A.M. Galactose biosensors using composite polymers to prevent interferences. Biosens. Bioelectron. 10 (1995) 359
    • (1995) Biosens. Bioelectron. , vol.10 , pp. 359
    • Manowitz, P.1    Stoecker, P.W.2    Yacynych, A.M.3
  • 18
    • 0032939591 scopus 로고    scopus 로고
    • Dual electrode signal-subtracted biosensor for simultaneous flow injection determination of sucrose and glucose
    • Surareungchai W., Worasing S., Sritongkum P., Tanticharoen M., and Kirtikara K. Dual electrode signal-subtracted biosensor for simultaneous flow injection determination of sucrose and glucose. Anal. Chim. Acta 380 (1999) 7
    • (1999) Anal. Chim. Acta , vol.380 , pp. 7
    • Surareungchai, W.1    Worasing, S.2    Sritongkum, P.3    Tanticharoen, M.4    Kirtikara, K.5
  • 19
    • 0032313369 scopus 로고    scopus 로고
    • A poly(o-aminophenol) modified electrode as an amperometric hydrogen peroxide biosensor
    • García M.A.V., Blanco P.T., and Ivaska A. A poly(o-aminophenol) modified electrode as an amperometric hydrogen peroxide biosensor. Electrochim. Acta 43 (1998) 3533
    • (1998) Electrochim. Acta , vol.43 , pp. 3533
    • García, M.A.V.1    Blanco, P.T.2    Ivaska, A.3
  • 20
    • 0000889645 scopus 로고    scopus 로고
    • A glucose biosensor based on immobilization of glucose oxidase in electropolymerized o-aminophenol film on platinized glassy carbon electrode
    • Zhang Z., Liu H., and Deng J. A glucose biosensor based on immobilization of glucose oxidase in electropolymerized o-aminophenol film on platinized glassy carbon electrode. Anal. Chem. 68 (1996) 1632
    • (1996) Anal. Chem. , vol.68 , pp. 1632
    • Zhang, Z.1    Liu, H.2    Deng, J.3
  • 21
    • 0001395950 scopus 로고
    • Synthesis and electrochromic properties of poly-o-aminophenol
    • Zhang A.Q., Cui C.Q., Chen Y.Z., and Lee J.Y. Synthesis and electrochromic properties of poly-o-aminophenol. J. Electroanal. Chem. 373 (1994) 115
    • (1994) J. Electroanal. Chem. , vol.373 , pp. 115
    • Zhang, A.Q.1    Cui, C.Q.2    Chen, Y.Z.3    Lee, J.Y.4
  • 22
    • 1942470076 scopus 로고    scopus 로고
    • Using electgropolymerized non-conducting polymers to develop enzyme amperometric biosensors
    • Miao Y., Chen J., and Wu X. Using electgropolymerized non-conducting polymers to develop enzyme amperometric biosensors. Trends Biotechnol. 22 (2004) 227
    • (2004) Trends Biotechnol. , vol.22 , pp. 227
    • Miao, Y.1    Chen, J.2    Wu, X.3
  • 23
    • 0029765550 scopus 로고    scopus 로고
    • Novel hexacyanoferrate(III)-modified carbon electrodes: application in miniaturized biosensors with potential for in vivo glucose sensing
    • Jaffari S.A., and Pickup J.C. Novel hexacyanoferrate(III)-modified carbon electrodes: application in miniaturized biosensors with potential for in vivo glucose sensing. Biosens. Bioelectron. 11 (1996) 1167
    • (1996) Biosens. Bioelectron. , vol.11 , pp. 1167
    • Jaffari, S.A.1    Pickup, J.C.2
  • 24
    • 0027590411 scopus 로고
    • Ferrocene-mediated needle type glucose sensor covered with newly designed biocompatible membrane
    • Sakakida M., Nishida K., Shichiri M., Ishihara K., and Nakabayashi N. Ferrocene-mediated needle type glucose sensor covered with newly designed biocompatible membrane. Sens. Actuators B 13-14 (1993) 319
    • (1993) Sens. Actuators B , vol.13-14 , pp. 319
    • Sakakida, M.1    Nishida, K.2    Shichiri, M.3    Ishihara, K.4    Nakabayashi, N.5
  • 25
    • 0000658389 scopus 로고    scopus 로고
    • Fabrication of butyrylcholinesterase sensor using polyurethane-based ion-selective membranes
    • Cho Y.A., Lee H.S., Cha G.S., and Lee Y.T. Fabrication of butyrylcholinesterase sensor using polyurethane-based ion-selective membranes. Biosens. Bioelectron. 14 (1999) 435
    • (1999) Biosens. Bioelectron. , vol.14 , pp. 435
    • Cho, Y.A.1    Lee, H.S.2    Cha, G.S.3    Lee, Y.T.4
  • 26
    • 0032117211 scopus 로고    scopus 로고
    • Potentiometric biosensors using immobilized emzyme layers mixed with hydrophilic polyurethane
    • Shin J.H., Yoon S.Y., Yoon I.J., Choi S.H., Lee S.D., Nam H., and Cha G.S. Potentiometric biosensors using immobilized emzyme layers mixed with hydrophilic polyurethane. Sens. Actuators B 50 (1998) 19
    • (1998) Sens. Actuators B , vol.50 , pp. 19
    • Shin, J.H.1    Yoon, S.Y.2    Yoon, I.J.3    Choi, S.H.4    Lee, S.D.5    Nam, H.6    Cha, G.S.7
  • 27
    • 0032495135 scopus 로고    scopus 로고
    • Studies on optimization of a platinum catalyst and phophine modified, pyrolytic graphite, amperometric glucose sensor by sequential level elimination experimental design
    • Sun L., Xu F., and Okada T. Studies on optimization of a platinum catalyst and phophine modified, pyrolytic graphite, amperometric glucose sensor by sequential level elimination experimental design. Talanta 47 (1998) 1165
    • (1998) Talanta , vol.47 , pp. 1165
    • Sun, L.1    Xu, F.2    Okada, T.3
  • 28
    • 0025233044 scopus 로고
    • A biocompatible enzyme electrode for continuous in vivo glucose monitoring in whole blood
    • Turner R.F.B., Harrison D.J., Rajotte R.V., and Baltes H.P. A biocompatible enzyme electrode for continuous in vivo glucose monitoring in whole blood. Sens. Actuators B 1 (1990) 561
    • (1990) Sens. Actuators B , vol.1 , pp. 561
    • Turner, R.F.B.1    Harrison, D.J.2    Rajotte, R.V.3    Baltes, H.P.4
  • 29
    • 2342644045 scopus 로고    scopus 로고
    • Biocompatibility and interference eliminating property of pullulan acetate/polyethyleneglycol/heparin membrane for the outer layer of an amperometric glucose sensor
    • Sung W.J., Na K., and Bae Y.H. Biocompatibility and interference eliminating property of pullulan acetate/polyethyleneglycol/heparin membrane for the outer layer of an amperometric glucose sensor. Sens. Actuators B 99 (2004) 393
    • (2004) Sens. Actuators B , vol.99 , pp. 393
    • Sung, W.J.1    Na, K.2    Bae, Y.H.3
  • 30
    • 0032851128 scopus 로고    scopus 로고
    • A ferric chloride pre-treatment to prevent calcification of Nifion membrane used for implantable biosensors
    • Valdes T.I., and Moussy F. A ferric chloride pre-treatment to prevent calcification of Nifion membrane used for implantable biosensors. Biosens. Bioelectron. 14 (1999) 579
    • (1999) Biosens. Bioelectron. , vol.14 , pp. 579
    • Valdes, T.I.1    Moussy, F.2
  • 31
    • 0032007128 scopus 로고    scopus 로고
    • In vitro and in vivo mineralization Nafion membrane used for implantable biosensors
    • Mercado R.C., and Moussy F. In vitro and in vivo mineralization Nafion membrane used for implantable biosensors. Biosens. Bioelectron. 13 (1998) 133
    • (1998) Biosens. Bioelectron. , vol.13 , pp. 133
    • Mercado, R.C.1    Moussy, F.2
  • 32
    • 0030575932 scopus 로고    scopus 로고
    • Diffusion restricting outer membranes for greatly extended linearity measurements with glucose oxidase enzyme electrodes
    • Maines A., Ashworth D., and Vadgama P. Diffusion restricting outer membranes for greatly extended linearity measurements with glucose oxidase enzyme electrodes. Anal. Chim. Acta 333 (1996) 223
    • (1996) Anal. Chim. Acta , vol.333 , pp. 223
    • Maines, A.1    Ashworth, D.2    Vadgama, P.3
  • 33
    • 0032816553 scopus 로고    scopus 로고
    • Modified gas-permeable silicon rubber membranes for covalent immobilization of enzymes and their use in biosensor development
    • Schüler R., Wittkampf M., and Chemnitius G.-C. Modified gas-permeable silicon rubber membranes for covalent immobilization of enzymes and their use in biosensor development. Anaylst 124 (1999) 1181
    • (1999) Anaylst , vol.124 , pp. 1181
    • Schüler, R.1    Wittkampf, M.2    Chemnitius, G.-C.3
  • 34
    • 26944446945 scopus 로고    scopus 로고
    • Novel micromachined silicon sensor for continuous glucose monitoring
    • Piechotta G., Albers J., and Hitsche R. Novel micromachined silicon sensor for continuous glucose monitoring. Biosens. Bioelectron. 21 (2005) 802
    • (2005) Biosens. Bioelectron. , vol.21 , pp. 802
    • Piechotta, G.1    Albers, J.2    Hitsche, R.3
  • 35
    • 0029929994 scopus 로고    scopus 로고
    • Poly(vinyl chloride), polysulfone and sulfonated polyether-ether sulfone composite membranes for glucose and hydrogen peroxide perm-selectivity in amperometric biosensors
    • Benmakroha Y., Christie I., Desai M., and Vadgama P. Poly(vinyl chloride), polysulfone and sulfonated polyether-ether sulfone composite membranes for glucose and hydrogen peroxide perm-selectivity in amperometric biosensors. Analyst 121 (1996) 521
    • (1996) Analyst , vol.121 , pp. 521
    • Benmakroha, Y.1    Christie, I.2    Desai, M.3    Vadgama, P.4
  • 36
    • 2342573708 scopus 로고    scopus 로고
    • Multifunctional biocompatible membrane and its application to fabricate a miniaturized glucose sensor with potential for use in vivo
    • Chen C., Ishihara K., Nakabayashi N., Tamiya E., and Karube I. Multifunctional biocompatible membrane and its application to fabricate a miniaturized glucose sensor with potential for use in vivo. Biomed. Microdevices 1 (1999) 155
    • (1999) Biomed. Microdevices , vol.1 , pp. 155
    • Chen, C.1    Ishihara, K.2    Nakabayashi, N.3    Tamiya, E.4    Karube, I.5
  • 39
    • 0026816698 scopus 로고
    • Structural and emzymatic characterization of papain immobilized onto vinyl alcohol/vinyl butyral copolymer membrane
    • Zhuang P., and Butterfield D.A. Structural and emzymatic characterization of papain immobilized onto vinyl alcohol/vinyl butyral copolymer membrane. J. Membr. Sci. 66 (1992) 247
    • (1992) J. Membr. Sci. , vol.66 , pp. 247
    • Zhuang, P.1    Butterfield, D.A.2
  • 40
    • 0343335563 scopus 로고    scopus 로고
    • Characteristics of oxygen permeable polypropylene with a membrane-covered electrode
    • Jung T.H., Hong S.I., and Kim T.K. Characteristics of oxygen permeable polypropylene with a membrane-covered electrode. Hwahak Konghak. 34 (1996) 489
    • (1996) Hwahak Konghak. , vol.34 , pp. 489
    • Jung, T.H.1    Hong, S.I.2    Kim, T.K.3
  • 41
    • 0031572842 scopus 로고    scopus 로고
    • Photo-cross-linked decyl methacrylate films for electrochemical and optical polyion probes
    • Ambrose T.M., and Meyerhoff M.E. Photo-cross-linked decyl methacrylate films for electrochemical and optical polyion probes. Anal. Chem. 69 (1997) 4092
    • (1997) Anal. Chem. , vol.69 , pp. 4092
    • Ambrose, T.M.1    Meyerhoff, M.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.