메뉴 건너뛰기




Volumn 50, Issue 1, 1998, Pages 19-26

Potentiometric biosensors using immobilized enzyme layers mixed with hydrophilic polyurethane

Author keywords

Asymmetric membranes; Biosensors; Polyurethane membranes; Potentiometric sensors; Solid state sensors

Indexed keywords

CROSSLINKING; GLUCOSE SENSORS; PLASTIC COATINGS; PLASTIC FILMS; POLYMERIC MEMBRANES; POLYURETHANES; POTENTIOMETRIC SENSORS; THIN FILMS;

EID: 0032117211     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0925-4005(98)00151-8     Document Type: Article
Times cited : (40)

References (15)
  • 1
    • 0028985807 scopus 로고
    • Evaluation of the i-STAT system: A portable chemistry analyzer for the measurement of sodium, potassium, chloride, urea and hematocrit
    • T. Mock, D. Morrison, R. Yatscoff, Evaluation of the i-STAT system: a portable chemistry analyzer for the measurement of sodium, potassium, chloride, urea and hematocrit, Clin. Biochem. 28 (1995) 187-192.
    • (1995) Clin. Biochem. , vol.28 , pp. 187-192
    • Mock, T.1    Morrison, D.2    Yatscoff, R.3
  • 3
    • 0024907303 scopus 로고
    • Biosensors: Current status and future possibilities
    • G.G. Guilbault, J.H. Luong, Biosensors: current status and future possibilities, Sel. Electrode Rev. 11 (1989) 3-16.
    • (1989) Sel. Electrode Rev. , vol.11 , pp. 3-16
    • Guilbault, G.G.1    Luong, J.H.2
  • 5
    • 84987574183 scopus 로고
    • Application of ion-selective electrodes in clinical analysis
    • A. Lewenstam, M. Maj-Zurawska, A. Hulanicki, Application of ion-selective electrodes in clinical analysis, Electroanalysis 3 (1991) 727-734.
    • (1991) Electroanalysis , vol.3 , pp. 727-734
    • Lewenstam, A.1    Maj-Zurawska, M.2    Hulanicki, A.3
  • 6
    • 33644919327 scopus 로고
    • Potentiometric ion- And bio-selective electrodes based on asymmetric cellulose acetate membranes
    • G.S. Cha, M.E. Meyerhoff, Potentiometric ion- and bio-selective electrodes based on asymmetric cellulose acetate membranes, Talanta 36 (1989) 271-278.
    • (1989) Talanta , vol.36 , pp. 271-278
    • Cha, G.S.1    Meyerhoff, M.E.2
  • 7
    • 84987564729 scopus 로고
    • Enzyme electrode-based differential potentiometric cell with enhanced substrate sensitivity
    • G.S. Cha, M.E. Meyerhoff, Enzyme electrode-based differential potentiometric cell with enhanced substrate sensitivity, Electroanalysis 1 (1989) 205-211.
    • (1989) Electroanalysis , vol.1 , pp. 205-211
    • Cha, G.S.1    Meyerhoff, M.E.2
  • 8
    • 0027402740 scopus 로고
    • Potentiometric ion- And bioselective electrodes based on asymmetric polyurethane membranes
    • D. Liu, M.E. Meyerhoff, H.D. Goldberg, R.B. Brown, Potentiometric ion- and bioselective electrodes based on asymmetric polyurethane membranes, Anal. Chim. Acta 274 (1993) 37-46.
    • (1993) Anal. Chim. Acta , vol.274 , pp. 37-46
    • Liu, D.1    Meyerhoff, M.E.2    Goldberg, H.D.3    Brown, R.B.4
  • 9
    • 0026216161 scopus 로고
    • Electrochemical performance, bio-compatibility and adhesion of new polymer matrices for solid-state ion sensors
    • G.S. Cha, D. Liu, M.E. Meyerhoff, H.C. Cantor, A.R. Midgley, H.D. Goldberg, R.B. Brown, Electrochemical performance, bio-compatibility and adhesion of new polymer matrices for solid-state ion sensors, Anal. Chem. 63 (1991) 1666-1672.
    • (1991) Anal. Chem. , vol.63 , pp. 1666-1672
    • Cha, G.S.1    Liu, D.2    Meyerhoff, M.E.3    Cantor, H.C.4    Midgley, A.R.5    Goldberg, H.D.6    Brown, R.B.7
  • 11
    • 0001110066 scopus 로고    scopus 로고
    • Enhanced serum carbon dioxide measurements with a silicone rubber-based carbonate ion-selective electrode and a high-pH dilution buffer
    • J.H. Shin, D.S. Sakong, H. Nam, G.S. Cha, Enhanced serum carbon dioxide measurements with a silicone rubber-based carbonate ion-selective electrode and a high-pH dilution buffer, Anal. Chem. 68 (1996) 221-225.
    • (1996) Anal. Chem. , vol.68 , pp. 221-225
    • Shin, J.H.1    Sakong, D.S.2    Nam, H.3    Cha, G.S.4
  • 12
    • 0005898447 scopus 로고    scopus 로고
    • All-solid-state sodium-selective electrodes based on room temperature vulcanizing-type silicone rubber matrix
    • H.J. Lee, H.J. Oh, G. Cui, G.S. Cha, H. Nam, All-solid-state sodium-selective electrodes based on room temperature vulcanizing-type silicone rubber matrix, Anal. Sci. Suppl. 13 (1997) 289-294.
    • (1997) Anal. Sci. Suppl. , vol.13 , pp. 289-294
    • Lee, H.J.1    Oh, H.J.2    Cui, G.3    Cha, G.S.4    Nam, H.5
  • 13
    • 0000666007 scopus 로고    scopus 로고
    • Potentiometric properties of ion-selective electrode membranes based on segmented polyether urethane matrices
    • S.Y. Yun, Y.K. Hong, B.K. Oh, G.S. Cha, H. Nam, Potentiometric properties of ion-selective electrode membranes based on segmented polyether urethane matrices, Anal. Chem. 69 (1997) 868-873.
    • (1997) Anal. Chem. , vol.69 , pp. 868-873
    • Yun, S.Y.1    Hong, Y.K.2    Oh, B.K.3    Cha, G.S.4    Nam, H.5
  • 14
    • 0030373977 scopus 로고    scopus 로고
    • Aliphatic polyurethane as a matrix for pH sensors: Effects of native sites and added proton carrier on electrical and potentiometric properties
    • V.V. Cosofret, M. Erdosy, J.S. Raleigh, T.A. Johnson, M.R. Neuman, R.P. Buck, Aliphatic polyurethane as a matrix for pH sensors: effects of native sites and added proton carrier on electrical and potentiometric properties, Talanta 43 (1996) 143-151.
    • (1996) Talanta , vol.43 , pp. 143-151
    • Cosofret, V.V.1    Erdosy, M.2    Raleigh, J.S.3    Johnson, T.A.4    Neuman, M.R.5    Buck, R.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.