메뉴 건너뛰기




Volumn 17, Issue 11-12, 2002, Pages 1005-1013

Glucose microbiosensor based on alumina sol-gel matrix/electropolymerized composite membrane

Author keywords

Electropolymerization; Glucose microbiosensor; Sol gel

Indexed keywords

ALUMINA; BIOLOGICAL MEMBRANES; ELECTROPOLYMERIZATION; ENZYME IMMOBILIZATION; GLUCOSE SENSORS; SOL-GELS; THIN FILMS;

EID: 0036883708     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(02)00093-3     Document Type: Article
Times cited : (100)

References (44)
  • 1
    • 0000324041 scopus 로고
    • Organic chemistry within ceramic matrixes: Doped sol-gel Materials
    • Avnir D. Organic chemistry within ceramic matrixes: doped sol-gel Materials. Acc. Chem. Res. 28:1995;328-334.
    • (1995) Acc. Chem. Res. , vol.28 , pp. 328-334
    • Avnir, D.1
  • 2
    • 33751158445 scopus 로고
    • Enzymes and other proteins entrapped in sol-gel materials
    • Avnir D., Braun S., Lev O., Ottolenghi M. Enzymes and other proteins entrapped in sol-gel materials. Chem. Mater. 6:1994;1605-1614.
    • (1994) Chem. Mater. , vol.6 , pp. 1605-1614
    • Avnir, D.1    Braun, S.2    Lev, O.3    Ottolenghi, M.4
  • 3
    • 0038281980 scopus 로고
    • A review of the immobilization of enzymes in electropolymerized films
    • Bartlett P.N., Cooper J.M. A review of the immobilization of enzymes in electropolymerized films. J. Electroanal. Chem. 362:1993;1-12.
    • (1993) J. Electroanal. Chem. , vol.362 , pp. 1-12
    • Bartlett, P.N.1    Cooper, J.M.2
  • 7
    • 0032636753 scopus 로고    scopus 로고
    • Sol-gel derived mesoporous γ-alumina granules
    • Buelna G., Lin Y.S. Sol-gel derived mesoporous γ-alumina granules. Mecroporous Mesoporous Mat. 30:1999;359-369.
    • (1999) Mecroporous Mesoporous Mat. , vol.30 , pp. 359-369
    • Buelna, G.1    Lin, Y.S.2
  • 8
    • 0037080142 scopus 로고    scopus 로고
    • Electrochemically-mediated electrodeposition/electropolymerization yields enzyme microbiosensor with improved characteristics
    • Chen, X., Matsumoto, N., Hu, Y., Wilson, G.S., 2001. Electrochemically-mediated electrodeposition/electropolymerization yields enzyme microbiosensor with improved characteristics. Anal. Chem. 74, 368-372.
    • (2001) Anal. Chem. , vol.74 , pp. 368-372
    • Chen, X.1    Matsumoto, N.2    Hu, Y.3    Wilson, G.S.4
  • 9
    • 0027415524 scopus 로고
    • Modification of electrode surfaces with oxidized phenols to confer selectivity to amperometric biosensors for glucose determination
    • Christie I.M., Vadgama P., Lloyd S. Modification of electrode surfaces with oxidized phenols to confer selectivity to amperometric biosensors for glucose determination. Anal. Chim. Acta. 274:1993;191-199.
    • (1993) Anal. Chim. Acta , vol.274 , pp. 191-199
    • Christie, I.M.1    Vadgama, P.2    Lloyd, S.3
  • 10
    • 0032164157 scopus 로고    scopus 로고
    • An amperometric urea biosensor based on a polyaniline-perfluorosulfonated ionomer composite electrode
    • Cho W., Huang H. An amperometric urea biosensor based on a polyaniline-perfluorosulfonated ionomer composite electrode. Anal. Chem. 70:1998;3946-3951.
    • (1998) Anal. Chem. , vol.70 , pp. 3946-3951
    • Cho, W.1    Huang, H.2
  • 11
    • 0033501373 scopus 로고    scopus 로고
    • Sol-gel strategies for the preparation of selective materials for chemical analysis
    • Collinson M.M. Sol-gel strategies for the preparation of selective materials for chemical analysis. Crit. Rev. Anal. Chem. 29:1999;289-311.
    • (1999) Crit. Rev. Anal. Chem. , vol.29 , pp. 289-311
    • Collinson, M.M.1
  • 12
    • 0034310819 scopus 로고    scopus 로고
    • Sol-gels and electrochemistry: Research at the intersection
    • and references within
    • Collinson M.M., Howell A.R. Sol-gels and electrochemistry: research at the intersection. Anal. Chem. 72:2000;702A-709A. and references within.
    • (2000) Anal. Chem. , vol.72
    • Collinson, M.M.1    Howell, A.R.2
  • 13
    • 0001701618 scopus 로고    scopus 로고
    • Electropolymerization of amphiphilic monomers for designing amperometric biosensors
    • Cosnier S. Electropolymerization of amphiphilic monomers for designing amperometric biosensors. Electroanalysis. 9:1997;894-902.
    • (1997) Electroanalysis , vol.9 , pp. 894-902
    • Cosnier, S.1
  • 17
    • 84987566723 scopus 로고
    • Use of polymer films in amperometric biosensors
    • Emr S.A., Yacynych A.M. Use of polymer films in amperometric biosensors. Electroanalysis. 7:1995;913-923.
    • (1995) Electroanalysis , vol.7 , pp. 913-923
    • Emr, S.A.1    Yacynych, A.M.2
  • 18
    • 0025762538 scopus 로고
    • Electropolymerized films to prevent interferences and electrode fouling in biosensors
    • Geise R.J., Adams J.M., Barone N.J., Yacynych A.M. Electropolymerized films to prevent interferences and electrode fouling in biosensors. Biosens. Bioelectron. 6:1991;151-160.
    • (1991) Biosens. Bioelectron. , vol.6 , pp. 151-160
    • Geise, R.J.1    Adams, J.M.2    Barone, N.J.3    Yacynych, A.M.4
  • 19
    • 0031889621 scopus 로고    scopus 로고
    • Electrosynthesized non-conducting polymers as permselective membranes in amperometric enzyme electrodes: A glucose biosensor based on a co-crosslinked GOx/overoxidized polypyrrole bilayer
    • Guerrieri A., de Benedetto G.E., Palmisano F., Zambonin P.G. Electrosynthesized non-conducting polymers as permselective membranes in amperometric enzyme electrodes: a glucose biosensor based on a co-crosslinked GOx/overoxidized polypyrrole bilayer. Biosens. Bioelectron. 13:1998;103-112.
    • (1998) Biosens. Bioelectron. , vol.13 , pp. 103-112
    • Guerrieri, A.1    De Benedetto, G.E.2    Palmisano, F.3    Zambonin, P.G.4
  • 21
    • 0024095481 scopus 로고
    • Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood
    • Harrison D.J., Turner R.F.B., Baltes H.P. Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood. Anal. Chem. 60:1988;2002-2007.
    • (1988) Anal. Chem. , vol.60 , pp. 2002-2007
    • Harrison, D.J.1    Turner, R.F.B.2    Baltes, H.P.3
  • 22
    • 0033559314 scopus 로고    scopus 로고
    • Kinetics and thermodynamics of free flavins and the flavin-based redox active site within GOx dissolved in solution or sequestered within a sol-gel derived glass
    • Hartnett A.M., Ingersoll C.M., Baker G.A., Bright F.V. Kinetics and thermodynamics of free flavins and the flavin-based redox active site within GOx dissolved in solution or sequestered within a sol-gel derived glass. Anal. Chem. 71:1999;1215-1224.
    • (1999) Anal. Chem. , vol.71 , pp. 1215-1224
    • Hartnett, A.M.1    Ingersoll, C.M.2    Baker, G.A.3    Bright, F.V.4
  • 23
    • 0003310264 scopus 로고
    • The sol-gel process
    • Hench L.L., West J.K. The sol-gel process. Chem. Rev. 90:1990;33-72.
    • (1990) Chem. Rev. , vol.90 , pp. 33-72
    • Hench, L.L.1    West, J.K.2
  • 24
    • 0030894684 scopus 로고    scopus 로고
    • Rapid changes in local extracellular rat brain glucose observed with an in vivo glucose sensor
    • Hu Y., Wilson G.S. Rapid changes in local extracellular rat brain glucose observed with an in vivo glucose sensor. J. Neurochem. 68:1997;1745-1752.
    • (1997) J. Neurochem. , vol.68 , pp. 1745-1752
    • Hu, Y.1    Wilson, G.S.2
  • 25
    • 0030584128 scopus 로고    scopus 로고
    • Polymeric mercaptosilane-modified platinum electrodes for elimination of interferents in glucose biosensors
    • Jung S.-K., Wilson G.S. Polymeric mercaptosilane-modified platinum electrodes for elimination of interferents in glucose biosensors. Anal. Chem. 68:1996;591-596.
    • (1996) Anal. Chem. , vol.68 , pp. 591-596
    • Jung, S.-K.1    Wilson, G.S.2
  • 29
    • 0031128409 scopus 로고    scopus 로고
    • Sol-gel glass as a matrix for chemical and biochemical sensing
    • and references within
    • Lin J., Brown C.W. Sol-gel glass as a matrix for chemical and biochemical sensing. Trends Anal. Chem. 16:1997;200-211. and references within.
    • (1997) Trends Anal. Chem. , vol.16 , pp. 200-211
    • Lin, J.1    Brown, C.W.2
  • 30
    • 0028279952 scopus 로고
    • Amperometric biosensor for in vivo glucose sensing based on GOx immobilized in a redox hydrogel
    • Linke B., Kerner W., Kiwit M., Pishko M., Heller A. Amperometric biosensor for in vivo glucose sensing based on GOx immobilized in a redox hydrogel. Biosens. Bioelectron. 9:1994;151-158.
    • (1994) Biosens. Bioelectron. , vol.9 , pp. 151-158
    • Linke, B.1    Kerner, W.2    Kiwit, M.3    Pishko, M.4    Heller, A.5
  • 32
    • 0032090602 scopus 로고    scopus 로고
    • A micro-planar amperometric glucose sensor unsusceptible to interference species
    • Matsumoto T., Furusawa M., Fujiwasa H., Matsumoto Y., Ito N. A micro-planar amperometric glucose sensor unsusceptible to interference species. Sens. Actuators. B49:1998;68-72.
    • (1998) Sens. Actuators , vol.B49 , pp. 68-72
    • Matsumoto, T.1    Furusawa, M.2    Fujiwasa, H.3    Matsumoto, Y.4    Ito, N.5
  • 33
    • 0032565710 scopus 로고    scopus 로고
    • GOx/polyion complex-bilayer membrane for elimination of electroactive interferents in amperometric glucose sensor
    • Mizutani F., Sato Y., Hirata Y., Sawaguchi S., Yabuki S. GOx/polyion complex-bilayer membrane for elimination of electroactive interferents in amperometric glucose sensor. Anal. Chim. Acta. 364:1998;173-179.
    • (1998) Anal. Chim. Acta , vol.364 , pp. 173-179
    • Mizutani, F.1    Sato, Y.2    Hirata, Y.3    Sawaguchi, S.4    Yabuki, S.5
  • 34
    • 0030638588 scopus 로고    scopus 로고
    • Commercial biosensors for medical application
    • F.W. Scheller, F. Schubert, & J. Fedrowitz. Boston: Birkhaüser Verlag
    • Pfeiffer D. Commercial biosensors for medical application. Scheller F.W., Schubert F., Fedrowitz J., Frontiers in Biosensorics II Practical Applications. 1997;149-160 Birkhaüser Verlag, Boston.
    • (1997) Frontiers in Biosensorics II Practical Applications , pp. 149-160
    • Pfeiffer, D.1
  • 36
    • 0004291439 scopus 로고
    • A.P.F. Turner, I. Karube, & G.S. Wilson. New York: Oxford University Press
    • Turner A.P.F., Karube I., Wilson G.S., Biosensors: Fundamentals and Applications. 1987;Oxford University Press, New York.
    • (1987) Biosensors: Fundamentals and Applications
  • 37
    • 0027068213 scopus 로고
    • Miniaturized multi-enzyme biosensors integrated with pH sensors on flexible polymer carriers for in vivo applications
    • Urban G., Jobst G., Keplinger F., Aschauer E., Tilado O., Fasching R., Kohl F. Miniaturized multi-enzyme biosensors integrated with pH sensors on flexible polymer carriers for in vivo applications. Biosens. Bioelectron. 7:1992;733-739.
    • (1992) Biosens. Bioelectron. , vol.7 , pp. 733-739
    • Urban, G.1    Jobst, G.2    Keplinger, F.3    Aschauer, E.4    Tilado, O.5    Fasching, R.6    Kohl, F.7
  • 38
    • 0000412121 scopus 로고
    • Electroanalysis and biosensors
    • Wang J. Electroanalysis and biosensors. Anal. Chem. 67:1995;487R-492R.
    • (1995) Anal. Chem. , vol.67
    • Wang, J.1
  • 39
    • 0032129145 scopus 로고    scopus 로고
    • Amperometric glucose biosensor based on sol-gel organic-inorganic hybrid material
    • Wang B., Li B., Deng Q., Dong S. Amperometric glucose biosensor based on sol-gel organic-inorganic hybrid material. Anal. Chem. 70:1998;3170-3174.
    • (1998) Anal. Chem. , vol.70 , pp. 3170-3174
    • Wang, B.1    Li, B.2    Deng, Q.3    Dong, S.4
  • 40
    • 0034435380 scopus 로고    scopus 로고
    • Sol-gel based glucose biosensors employing optical oxygen transducers, and a method for compensating for variable oxygen background
    • Wolfbeis O.S., Oehme I., Papkovskaya N., Klimant I. Sol-gel based glucose biosensors employing optical oxygen transducers, and a method for compensating for variable oxygen background. Biosens. Bioelectron. 15:2000;69-76.
    • (2000) Biosens. Bioelectron. , vol.15 , pp. 69-76
    • Wolfbeis, O.S.1    Oehme, I.2    Papkovskaya, N.3    Klimant, I.4
  • 42
    • 0031937009 scopus 로고    scopus 로고
    • Amperometric biosensor with a composite membrane of sol-gel derived enzyme film and electrochemically generated poly(1,2-diaminobenzene) film
    • Yao T., Takashima K. Amperometric biosensor with a composite membrane of sol-gel derived enzyme film and electrochemically generated poly(1,2-diaminobenzene) film. Biosens. Bioelectron. 13:1998;67-73.
    • (1998) Biosens. Bioelectron. , vol.13 , pp. 67-73
    • Yao, T.1    Takashima, K.2
  • 43
    • 0027236355 scopus 로고
    • In vitro and in vivo evaluation of oxygen effects on a GOx based implantable glucose sensor
    • Zhang Y., Wilson G.S. In vitro and in vivo evaluation of oxygen effects on a GOx based implantable glucose sensor. Anal. Chim. Acta. 281:1993;513-520.
    • (1993) Anal. Chim. Acta , vol.281 , pp. 513-520
    • Zhang, Y.1    Wilson, G.S.2
  • 44
    • 0028418786 scopus 로고
    • Elimination of the acetaminophen interference in an implantable glucose sensor
    • Zhang Y., Hu Y., Wilson G.S., Moatti-Sirat D., Poitout V., Reach G. Elimination of the acetaminophen interference in an implantable glucose sensor. Anal. Chem. 66:1994;1183-1188.
    • (1994) Anal. Chem. , vol.66 , pp. 1183-1188
    • Zhang, Y.1    Hu, Y.2    Wilson, G.S.3    Moatti-Sirat, D.4    Poitout, V.5    Reach, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.