-
1
-
-
0037439166
-
Donor site morbidity after anterior iliac crest bone harvest for single-level anterior cervical discectomy and fusion
-
Silber J S, Anderson D G, Daffner S D, Brislin B T, Leland J M, Hilibrand A S, Vaccaro A R and Albert T J 2003 Donor site morbidity after anterior iliac crest bone harvest for single-level anterior cervical discectomy and fusion Spine 28 134-9
-
(2003)
Spine
, vol.28
, Issue.2
, pp. 134-139
-
-
Silber, J.S.1
Anderson, D.G.2
Daffner, S.D.3
Brislin, B.T.4
Leland, J.M.5
Hilibrand, A.S.6
Vaccaro, A.R.7
Albert, T.J.8
-
3
-
-
0345524650
-
Subtotal and total vertebral body replacement and interbody fusion with porous Ti-Ni implants
-
Silberstein B M 1997 Subtotal and total vertebral body replacement and interbody fusion with porous Ti-Ni implants Shape Memory and Superelastic Technologies, Proc. SMST-97 (Pacific Grove, CA) ed A R Pelton, D Hodgson, S M Russell and T W Duerig pp617-21
-
(1997)
Shape Memory and Superelastic Technologies, Proc. SMST-97
, pp. 617-621
-
-
Silberstein, B.M.1
Pelton, A.R.2
Hodgson, D.3
Russell, S.M.4
Duerig, T.W.5
-
5
-
-
2642588023
-
Porous TiNi device for degenerative disc diseases: Pre-clinical study
-
Jarzem P, Leroux MA, Assad M, Simonovich A, Fomichev N and Baykylov A 2002 Porous TiNi device for degenerative disc diseases: pre-clinical study 48th Annual Mtg of the Orthopaedic Research Society (Dallas, TX, USA, Feb. 2002)
-
(2002)
48th Annual Mtg of the Orthopaedic Research Society
-
-
Jarzem, P.1
Ma, L.2
Assad, M.3
Simonovich, A.4
Fomichev, N.5
Baykylov, A.6
-
6
-
-
0142133589
-
Porous titanium-nickel for intervertebral fusion in a sheep model: Part 1. Histomorphometric and radiological analysis
-
Assad M, Jarzem P, Leroux M A, Coillard C, Chernyshov A V, Charette S and Rivard C H 2003 Porous titanium-nickel for intervertebral fusion in a sheep model: part 1. Histomorphometric and radiological analysis J. Biomed. Mater. Res. B 64 107-20
-
(2003)
J. Biomed. Mater. Res.
, vol.64
, Issue.2
, pp. 107-120
-
-
Assad, M.1
Jarzem, P.2
Leroux, M.A.3
Coillard, C.4
Chernyshov, A.V.5
Charette, S.6
Rivard, C.H.7
-
7
-
-
33947649984
-
Corrosion resistance of porous nickel titanium alloys for medical applications
-
Hernandez R, Polizu S, Cissé O, Savadogo O and Yahia L 2002 Corrosion resistance of porous nickel titanium alloys for medical applications 28th Annual Mtg of the Society for Biomaterials (Tampa, FL, USA, 2002) p44
-
(2002)
28th Annual Mtg of the Society for Biomaterials
, pp. 44
-
-
Hernandez, R.1
Polizu, S.2
Cissé, O.3
Savadogo, O.4
Yahia, L.5
-
8
-
-
0036181784
-
Characteristics of porous nickel-titanium alloys for medical applications
-
Hernandez R, Polizu S, Turenne S and Yahia L 2002 Characteristics of porous nickel-titanium alloys for medical applications Biomed. Mater. Eng. 12 37-45
-
(2002)
Biomed. Mater. Eng.
, vol.12
, pp. 37-45
-
-
Hernandez, R.1
Polizu, S.2
Turenne, S.3
Yahia, L.4
-
9
-
-
0034666762
-
Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy
-
Thierry B, Tabrizian M, Trépanier C, Savadogo O and Yahia L 2000 Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy J. Biomed. Mater. Res. 51 685-93
-
(2000)
J. Biomed. Mater. Res.
, vol.51
, Issue.4
, pp. 685-693
-
-
Thierry, B.1
Tabrizian, M.2
Trépanier, C.3
Savadogo, O.4
Yahia, L.5
-
10
-
-
0032403412
-
Effect of modification of oxide layer on NiTi stent corrosion resistance
-
Trépanier C, Tabrizian M, Yahia L H, Bilodeau L and Piron D L 1998 Effect of modification of oxide layer on NiTi stent corrosion resistance J. Biomed. Mater. Res. 43 433-40
-
(1998)
J. Biomed. Mater. Res.
, vol.43
, Issue.4
, pp. 433-440
-
-
Trépanier, C.1
Tabrizian, M.2
Yahia, L.H.3
Bilodeau, L.4
Piron, D.L.5
-
12
-
-
23544453147
-
Corrosion resistance and biocompatibility of passivated NiTi
-
Trépanier C, Venugopalan R and Pelton A 2000 Corrosion resistance and biocompatibility of passivated NiTi Shape Memory Implants ed L H Yahia (Berlin: Springer) pp35-45
-
(2000)
Shape Memory Implants
, pp. 35-45
-
-
Trépanier, C.1
Venugopalan, R.2
Pelton, A.3
-
13
-
-
1642618096
-
Assessing the corrosion behaviour of Nitinol for minimally-invasive device design
-
Venugopalan R and Trépanier C 2000 Assessing the corrosion behaviour of Nitinol for minimally-invasive device design Min. Invas. Ther. Allied Technol. 9 67-73
-
(2000)
Min. Invas. Ther. Allied Technol.
, vol.9
, pp. 67-73
-
-
Venugopalan, R.1
Trépanier, C.2
-
14
-
-
49949123492
-
A summary of recent research on the Nitinol alloys and their potential application in ocean engineering
-
Buehler W J and Wang F E 1967 A summary of recent research on the Nitinol alloys and their potential application in ocean engineering Ocean. Eng. 1 105-20
-
(1967)
Ocean. Eng.
, vol.1
, Issue.1
, pp. 105-120
-
-
Buehler, W.J.1
Wang, F.E.2
-
15
-
-
0019068816
-
Anodic polarisation behavior of Ti-Ni and Ti-6Al-4V in simulated physiological solutions
-
Speck K M and Fraker A C 1980 Anodic polarisation behavior of Ti-Ni and Ti-6Al-4V in simulated physiological solutions J. Dent. Res. 59 1590-5
-
(1980)
J. Dent. Res.
, vol.59
, pp. 1590-1595
-
-
Speck, K.M.1
Fraker, A.C.2
-
16
-
-
0019627753
-
Surface corrosion of nitinol and stainless steel under clinical conditions
-
Edie J W, Andreasen G F and Zaytoun M P 1981 Surface corrosion of nitinol and stainless steel under clinical conditions Angle Orthod. 51 319-24
-
(1981)
Angle Orthod.
, vol.51
, pp. 319-324
-
-
Edie, J.W.1
Andreasen, G.F.2
Zaytoun, M.P.3
-
18
-
-
0027342981
-
Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro
-
Barrett R D, Bishara S E and Quinn J K 1993 Biodegradation of orthodontic appliances. Part I. Biodegradation of nickel and chromium in vitro Am. J. Orthod. Dentofacial Orthop. 103 8-14
-
(1993)
Am. J. Orthod. Dentofacial Orthop.
, vol.103
, pp. 8-14
-
-
Barrett, R.D.1
Bishara, S.E.2
Quinn, J.K.3
-
19
-
-
0030272059
-
Corrosion resistance tests on NiTi shape memory alloy
-
Rondelli G 1996 Corrosion resistance tests on NiTi shape memory alloy Biomaterials 17 2003-8
-
(1996)
Biomaterials
, vol.17
, Issue.20
, pp. 2003-2008
-
-
Rondelli, G.1
-
20
-
-
0031181460
-
Corrosion behavior of 2205 duplex stainless steel
-
Platt J A, Guzman A, Zuccari A, Thornburg D W, Rhodes B F, Oshida Y and Moore B K 1997 Corrosion behavior of 2205 duplex stainless steel Am. J. Orthod. Dentofacial Orthop. 112 69-79
-
(1997)
Am. J. Orthod. Dentofacial Orthop.
, vol.112
, Issue.1
, pp. 69-79
-
-
Platt, J.A.1
Guzman, A.2
Zuccari, A.3
Thornburg, D.W.4
Rhodes, B.F.5
Oshida, Y.6
Moore, B.K.7
-
21
-
-
0030560906
-
Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer's solution
-
Montero-Ocampo C, Lopez H and Salinas R A 1996 Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer's solution J. Biomed. Mater. Res. 32 583-91
-
(1996)
J. Biomed. Mater. Res.
, vol.32
, Issue.4
, pp. 583-591
-
-
Montero-Ocampo, C.1
Lopez, H.2
Salinas, R.A.3
-
23
-
-
0027361059
-
Nitinol intravascular stent: Results of preclinical evaluation
-
Cragg A H, De Jong S C, Barnhart W H, Landas S K and Smith T P 1993 Nitinol intravascular stent: results of preclinical evaluation Radiology 189 775-8
-
(1993)
Radiology
, vol.189
, pp. 775-778
-
-
Cragg, A.H.1
De Jong, S.C.2
Barnhart, W.H.3
Landas, S.K.4
Smith, T.P.5
-
29
-
-
0037210041
-
In vitro corrosion behaviour and osteoblast response of thermally oxidised Ti6Al4V alloy
-
García-Alonso M C, Saldãa L, Vallés G, Gonzlez-Carrasco J L, Gonzlez-Cabrero J, Martínez M E, Gil-Garay E and Munuera L 2003 In vitro corrosion behaviour and osteoblast response of thermally oxidised Ti6Al4V alloy Biomaterials 24 19-26
-
(2003)
Biomaterials
, vol.24
, Issue.1
, pp. 19-26
-
-
García-Alonso, M.C.1
Saldãa, L.2
Vallés, G.3
Gonzlez-Carrasco, J.L.4
Gonzlez-Cabrero, J.5
Martínez, M.E.6
Gil-Garay, E.7
Munuera, L.8
-
30
-
-
0036179018
-
Surface, corrosion and biocompatibility aspects of Nitinol as an implant material
-
Shabalovskaya S A 2002 Surface, corrosion and biocompatibility aspects of Nitinol as an implant material Bio-Med. Mater. Eng. 12 69-109
-
(2002)
Bio-Med. Mater. Eng.
, vol.12
, pp. 69-109
-
-
Shabalovskaya, S.A.1
-
31
-
-
0032403412
-
Effect of modification of oxide layer on NiTi stent corrosion resistance
-
Trépanier C, Tabrizian M, Yahia L H, Bilodeau L and Piron D L 1998 Effect of modification of oxide layer on NiTi stent corrosion resistance J. Biomed. Mater. Res. 43 433-40
-
(1998)
J. Biomed. Mater. Res.
, vol.43
, Issue.4
, pp. 433-440
-
-
Trépanier, C.1
Tabrizian, M.2
Yahia, L.H.3
Bilodeau, L.4
Piron, D.L.5
-
32
-
-
33947634474
-
-
Ryhänen J 1999 Biocompatibility evaluation of nickel-titanium shape memory metal alloy PhD Department of Surgery, University of Oulu, Finland
-
(1999)
PhD
-
-
Ryhänen, J.1
-
33
-
-
0002052560
-
Corrosion resistance and biological evaluation of Ni-Ti alloys with varied surface textures
-
Abiko Y, Sachdeva R, Endo K, Araki Y, Kaku T and Ohno H 1995 Corrosion resistance and biological evaluation of Ni-Ti alloys with varied surface textures SMST: Proc. 1st Int. Conf. on Shape Memory and Superelastic Technologies (Monterey, CA, USA, 1995) pp203-8
-
(1995)
SMST: Proc. 1st Int. Conf. on Shape Memory and Superelastic Technologies
, pp. 203-208
-
-
Abiko, Y.1
Sachdeva, R.2
Endo, K.3
Araki, Y.4
Kaku, T.5
Ohno, H.6
-
34
-
-
0242499197
-
Effect of pores on corrosion characteristics of porous NiTi alloy in simulated body fluid
-
Li Y H, Rao G B, Rong L J, Li Y Y and Ke W 2003 Effect of pores on corrosion characteristics of porous NiTi alloy in simulated body fluid Mater. Sci. Eng. A 363 356-9
-
(2003)
Mater. Sci. Eng.
, vol.363
, Issue.1-2
, pp. 356-359
-
-
Li, Y.H.1
Rao, G.B.2
Rong, L.J.3
Li, Y.Y.4
Ke, W.5
-
35
-
-
0036013926
-
On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility
-
Es-Souni M, Es-Souni M and Fisher-Brandies H 2002 On the properties of two binary NiTi shape memory alloys. Effects of surface finish on the corrosion behaviour and in vitro biocompatibility Biomaterials 23 2887-94
-
(2002)
Biomaterials
, vol.23
, Issue.14
, pp. 2887-2894
-
-
Es-Souni, M.1
Es-Souni, M.2
Fisher-Brandies, H.3
-
36
-
-
0036210742
-
Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys
-
Schiff N, Grosgogeat B, Lissac M and Dalard F 2002 Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys Biomaterials 23 1995-2002
-
(2002)
Biomaterials
, vol.23
, Issue.9
, pp. 1995-2002
-
-
Schiff, N.1
Grosgogeat, B.2
Lissac, M.3
Dalard, F.4
-
37
-
-
0037089606
-
Passivation of nitinol wire for vascular implants-a demonstration of the benefits
-
O'Brien B, Carroll W M and Kelly M J 2002 Passivation of nitinol wire for vascular implants-a demonstration of the benefits Biomaterials 23 1739-48
-
(2002)
Biomaterials
, vol.23
, Issue.8
, pp. 1739-1748
-
-
O'Brien, B.1
Carroll, W.M.2
Kelly, M.J.3
-
38
-
-
33947695116
-
Biocompatibility improvement of NiTi with a functionally graded surface
-
Tan L, Bauer J, Crone W C and Albrecht R M 2002 Biocompatibility improvement of NiTi with a functionally graded surface Society for Experimental Mechanics, 2002 SEM Annual Conf. Proc. (Milwaukee, WI, 2002)
-
(2002)
Society for Experimental Mechanics, 2002 SEM Annual Conf. Proc.
-
-
Tan, L.1
Bauer, J.2
Crone, W.C.3
Albrecht, R.M.4
-
40
-
-
33947685348
-
Corrosion characteristics of cancellous-structured titanium
-
Zhu M 1999 Corrosion characteristics of cancellous-structured titanium 45th Annual Mtg, Orthopaedic Research Society (Anaheim, CA, Feb. 1999)
-
(1999)
45th Annual Mtg, Orthopaedic Research Society
-
-
Zhu, M.1
-
41
-
-
0035989692
-
Effect of phosphorus-ion implantation on the corrosion resistance and biocompatibility of titanium
-
Krupa D, Baszkiewicz J, Kozubowski J A, Barcz A, Sobczak J W, Bilinski A, Lewandowska-Szumiel M and Rajchel B 2002 Effect of phosphorus-ion implantation on the corrosion resistance and biocompatibility of titanium Biomaterials 23 3329-40
-
(2002)
Biomaterials
, vol.23
, Issue.16
, pp. 3329-3340
-
-
Krupa, D.1
Baszkiewicz, J.2
Kozubowski, J.A.3
Barcz, A.4
Sobczak, J.W.5
Bilinski, A.6
Lewandowska-Szumiel, M.7
Rajchel, B.8
-
43
-
-
0037209975
-
Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4V alloy
-
Huang H H 2003 Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4V alloy Biomaterials 24 275-82
-
(2003)
Biomaterials
, vol.24
, Issue.2
, pp. 275-282
-
-
Huang, H.H.1
-
44
-
-
0036210742
-
Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys
-
Schiff N, Grosgogeat B, Lissac M and Dalard F 2002 Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys Biomaterials 23 1995-2002
-
(2002)
Biomaterials
, vol.23
, Issue.9
, pp. 1995-2002
-
-
Schiff, N.1
Grosgogeat, B.2
Lissac, M.3
Dalard, F.4
-
45
-
-
33947652618
-
-
Lin H Y 2002 Short term observations of in vitro biocorrosion of two commonly used implant alloys PhD Department of Agricultural and Biological Engineering, Mississippi State University, USA
-
(2002)
PhD
-
-
Lin, H.Y.1
|