1
-
-
0141706611
-
Guidelines for antibiotic prophylaxis for GI endoscopy
-
Hirota W.K., Petersen K., Baron T.H., et al. Guidelines for antibiotic prophylaxis for GI endoscopy. Gastrointest Endosc 58 (2003) 475-482
-
(2003)
Gastrointest Endosc
, vol.58
, pp. 475-482
-
-
Hirota, W.K.1
Petersen, K.2
Baron, T.H.3
-
3
-
-
25644441845
-
ASGE technology status evaluation report: wireless esophageal pH monitoring system
-
Chotiprasidhi P., Liu J., Carpenter S., et al. ASGE technology status evaluation report: wireless esophageal pH monitoring system. Gastrointest Endosc 62 (2005) 485-487
-
(2005)
Gastrointest Endosc
, vol.62
, pp. 485-487
-
-
Chotiprasidhi, P.1
Liu, J.2
Carpenter, S.3
-
5
-
-
34247241147
-
-
American Society for Gastrointestinal Endoscopy. Polypectomy devices. Gastrointest Endosc 2007. In press.
-
-
-
-
8
-
-
0023138250
-
Current facts on pacemaker electromagnetic interference and their application to clinical care
-
Sager D.P. Current facts on pacemaker electromagnetic interference and their application to clinical care. Heart Lung 16 (1987) 211-221
-
(1987)
Heart Lung
, vol.16
, pp. 211-221
-
-
Sager, D.P.1
-
9
-
-
0017889938
-
Effect of coagulating current and cutting current on a demand pacemaker during transurethral resection of the prostate. A case report
-
Betra Y.K., and Bali I.M. Effect of coagulating current and cutting current on a demand pacemaker during transurethral resection of the prostate. A case report. Can Anaesth Soc J 25 (1978) 65-66
-
(1978)
Can Anaesth Soc J
, vol.25
, pp. 65-66
-
-
Betra, Y.K.1
Bali, I.M.2
-
10
-
-
0033504322
-
Surgical management of the patient with an implanted cardiac device: implications of electromagnetic interference
-
Madigan J.D., Choudhri A.F., Chen J., et al. Surgical management of the patient with an implanted cardiac device: implications of electromagnetic interference. Ann Surg 230 (1999) 639-647
-
(1999)
Ann Surg
, vol.230
, pp. 639-647
-
-
Madigan, J.D.1
Choudhri, A.F.2
Chen, J.3
-
11
-
-
0036741233
-
Interference in implanted cardiac devices, Part I
-
Pinski S.L., and Trohman R.G. Interference in implanted cardiac devices, Part I. Pacing Clin Electrophysiol 25 (2002) 1367-1381
-
(2002)
Pacing Clin Electrophysiol
, vol.25
, pp. 1367-1381
-
-
Pinski, S.L.1
Trohman, R.G.2
-
12
-
-
0036800992
-
Interference in implanted cardiac devices, Part II
-
Pinski S.L., and Trohman R.G. Interference in implanted cardiac devices, Part II. Pacing Clin Electrophysiol 25 (2002) 1496-1509
-
(2002)
Pacing Clin Electrophysiol
, vol.25
, pp. 1496-1509
-
-
Pinski, S.L.1
Trohman, R.G.2
-
13
-
-
33947433912
-
-
Hayes DL, Strathmore NF. Electromagnetic interference with implantable devices. In: Ellenbogen KA, Kay GN, Wilkoff BL, editors. Clinical cardiac pacing and defibrillation, 2nd ed. Philadelphia: Saunders; 2000.
-
-
-
-
14
-
-
0029893314
-
The patient with a pacemaker or related device
-
Bourke M.E. The patient with a pacemaker or related device. Can J Anaesth 43 (1996) R24-R32
-
(1996)
Can J Anaesth
, vol.43
-
-
Bourke, M.E.1
-
15
-
-
0022637562
-
Electrocautery and pacemakers: management of the paced patient subject to electrocautery
-
Levine P., Balady G., Lazar H., et al. Electrocautery and pacemakers: management of the paced patient subject to electrocautery. Ann Thorac Surg 41 (1986) 313-317
-
(1986)
Ann Thorac Surg
, vol.41
, pp. 313-317
-
-
Levine, P.1
Balady, G.2
Lazar, H.3
-
16
-
-
33947430888
-
-
Gregoratos G, Abrams J, Epstein AE et al. ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices. Available at: http://www.acc.org/qualityandscience/clinical/guidelines/pacemaker/index .htm. Accessed Sept 18, 2006.
-
-
-
-
17
-
-
0037149716
-
Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
-
Moss A.J., Zareba W., Hall W.J., et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 346 (2002) 877-883
-
(2002)
N Engl J Med
, vol.346
, pp. 877-883
-
-
Moss, A.J.1
Zareba, W.2
Hall, W.J.3
-
18
-
-
19944429413
-
Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
-
Bardy G.H., Lee K.L., Mark D.B., et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med 352 (2005) 225-237
-
(2005)
N Engl J Med
, vol.352
, pp. 225-237
-
-
Bardy, G.H.1
Lee, K.L.2
Mark, D.B.3
-
19
-
-
0242348703
-
Implantable cardioverter-defibrillators
-
DiMarco J.P. Implantable cardioverter-defibrillators. N Engl J Med 349 (2003) 1836-1847
-
(2003)
N Engl J Med
, vol.349
, pp. 1836-1847
-
-
DiMarco, J.P.1
-
20
-
-
0028205705
-
Endoscopic therapy using monopolar and bipolar snare with a high frequency current in patients with a pacemaker
-
Ito S., Shibata H., Okahisa T., et al. Endoscopic therapy using monopolar and bipolar snare with a high frequency current in patients with a pacemaker. Endoscopy 26 (1994) 270
-
(1994)
Endoscopy
, vol.26
, pp. 270
-
-
Ito, S.1
Shibata, H.2
Okahisa, T.3
-
21
-
-
0029351216
-
Endoscopic polypectomy for pacemaker patients
-
Tanigawa K., Yamashita S., Maeda Y., et al. Endoscopic polypectomy for pacemaker patients. Chin Med J (Engl) 108 (1995) 579-581
-
(1995)
Chin Med J (Engl)
, vol.108
, pp. 579-581
-
-
Tanigawa, K.1
Yamashita, S.2
Maeda, Y.3
-
22
-
-
0025788697
-
Electrocautery pacemaker malfunction during surgery
-
Mangar D., Atlas G., and Kane P. Electrocautery pacemaker malfunction during surgery. Can J Anaesth 38 (1991) 616-618
-
(1991)
Can J Anaesth
, vol.38
, pp. 616-618
-
-
Mangar, D.1
Atlas, G.2
Kane, P.3
-
23
-
-
0033932528
-
Intraoperative pacemaker malfunction during a shoulder arthroplasty
-
Samain E., Marty J., Souron V., et al. Intraoperative pacemaker malfunction during a shoulder arthroplasty. Anesthesiology 93 (2000) 306-307
-
(2000)
Anesthesiology
, vol.93
, pp. 306-307
-
-
Samain, E.1
Marty, J.2
Souron, V.3
-
24
-
-
0025052361
-
Surgical electrocautery and the runaway pacemaker syndrome
-
Heller L.I. Surgical electrocautery and the runaway pacemaker syndrome. Pacing Clin Electrophysiol 13 (1990) 1084-1085
-
(1990)
Pacing Clin Electrophysiol
, vol.13
, pp. 1084-1085
-
-
Heller, L.I.1
-
25
-
-
0032250450
-
Reversible prolonged pacemaker failure due to electrocautery
-
Peters R.W., and Gold M.R. Reversible prolonged pacemaker failure due to electrocautery. J Interv Card Electrophysiol 2 (1998) 343-344
-
(1998)
J Interv Card Electrophysiol
, vol.2
, pp. 343-344
-
-
Peters, R.W.1
Gold, M.R.2
-
26
-
-
0027411203
-
Pacemaker failure during transurethral resection of the prostate
-
Kellow N. Pacemaker failure during transurethral resection of the prostate. Anaesthesia 48 (1993) 136-138
-
(1993)
Anaesthesia
, vol.48
, pp. 136-138
-
-
Kellow, N.1
-
27
-
-
0035096547
-
Electrocautery-induced tachycardia in a rate-responsive pacemaker
-
Wong D.T., and Middleton W. Electrocautery-induced tachycardia in a rate-responsive pacemaker. Anesthesiology 94 (2001) 710-711
-
(2001)
Anesthesiology
, vol.94
, pp. 710-711
-
-
Wong, D.T.1
Middleton, W.2
-
28
-
-
0016834790
-
Cardiac pacemaker induced ventricular fibrillation during surgical diathermy
-
Orland H.J., and Jones D. Cardiac pacemaker induced ventricular fibrillation during surgical diathermy. Anaesth Intensive Care 3 (1975) 321-326
-
(1975)
Anaesth Intensive Care
, vol.3
, pp. 321-326
-
-
Orland, H.J.1
Jones, D.2
-
29
-
-
0031025494
-
Cardiac arrest from the use of diathermy during total hip arthroplasty in a patient with an external pacemaker
-
Andrade A.J., and Grover M.L. Cardiac arrest from the use of diathermy during total hip arthroplasty in a patient with an external pacemaker. Ann R Coll Surg Engl 79 (1997) 69-70
-
(1997)
Ann R Coll Surg Engl
, vol.79
, pp. 69-70
-
-
Andrade, A.J.1
Grover, M.L.2
-
30
-
-
0031811480
-
Aborted implantable cardioverter-defibrillator shock during facial electrosurgery
-
Casavant D., Haffajee C., Stevens S., et al. Aborted implantable cardioverter-defibrillator shock during facial electrosurgery. Pacing Clin Electrophysiol 21 (1998) 1325-1326
-
(1998)
Pacing Clin Electrophysiol
, vol.21
, pp. 1325-1326
-
-
Casavant, D.1
Haffajee, C.2
Stevens, S.3
-
31
-
-
0016474538
-
A new electrical hazard associated with electrocautery
-
Gedes L.A., Tacker W.A., and Cabler P. A new electrical hazard associated with electrocautery. Med Instrum 9 (1975) 112-113
-
(1975)
Med Instrum
, vol.9
, pp. 112-113
-
-
Gedes, L.A.1
Tacker, W.A.2
Cabler, P.3
-
32
-
-
0031851887
-
Intraoperative pacemaker dysfunction caused by the use of electrocautery during a total hip arthroplasty
-
Nercessian O.A., Wu H., Nazarian D., et al. Intraoperative pacemaker dysfunction caused by the use of electrocautery during a total hip arthroplasty. J Arthroplasty 13 (1998) 599-602
-
(1998)
J Arthroplasty
, vol.13
, pp. 599-602
-
-
Nercessian, O.A.1
Wu, H.2
Nazarian, D.3
-
33
-
-
0026065368
-
Electrocautery does not interfere with the function of the automatic implantable cardioverter defibrillator
-
Wilson J.H., Lattner S., Jacob R., et al. Electrocautery does not interfere with the function of the automatic implantable cardioverter defibrillator. Ann Thorac Surg 51 (1991) 225-226
-
(1991)
Ann Thorac Surg
, vol.51
, pp. 225-226
-
-
Wilson, J.H.1
Lattner, S.2
Jacob, R.3
-
34
-
-
1542611327
-
Application of radiofrequency energy in surgical and interventional procedures: are there interactions with ICDs?
-
Fiek M., Dorwarth U., Durchlaub I., et al. Application of radiofrequency energy in surgical and interventional procedures: are there interactions with ICDs?. Pacing Clin Electrophysiol 27 (2004) 293-298
-
(2004)
Pacing Clin Electrophysiol
, vol.27
, pp. 293-298
-
-
Fiek, M.1
Dorwarth, U.2
Durchlaub, I.3
-
35
-
-
21744447218
-
Practice advisory for the perioperative management of patients with cardiac rhythm management devices: pacemakers and implantable cardioverter-defibrillators: a report by the American Society of Anesthesiologists Task Force on Perioperative Management of Patients with Cardiac Rhythm Management Devices
-
American Society of Anesthesiologists Task Force on Perioperative Management of Patients with Cardiac Rhythm Management Devices. Practice advisory for the perioperative management of patients with cardiac rhythm management devices: pacemakers and implantable cardioverter-defibrillators: a report by the American Society of Anesthesiologists Task Force on Perioperative Management of Patients with Cardiac Rhythm Management Devices. Anesthesiology 103 (2005) 186-198
-
(2005)
Anesthesiology
, vol.103
, pp. 186-198
-
-
-
36
-
-
0036329522
-
Unintentional deactivation of implantable cardioverter-defibrillators in health care settings
-
Rasmussen M.J., Freidman P.A., Hammill S.C., et al. Unintentional deactivation of implantable cardioverter-defibrillators in health care settings. Mayo Clin Proc 77 (2002) 855-859
-
(2002)
Mayo Clin Proc
, vol.77
, pp. 855-859
-
-
Rasmussen, M.J.1
Freidman, P.A.2
Hammill, S.C.3
-
37
-
-
0035848350
-
Environmental and drug effects on patients with pacemakers and implantable cardioverter/defibrillators: a practical guide to patient treatment
-
Goldschlager N., Epstein A., Friedman P., et al. Environmental and drug effects on patients with pacemakers and implantable cardioverter/defibrillators: a practical guide to patient treatment. Arch Intern Med 161 (2001) 649-655
-
(2001)
Arch Intern Med
, vol.161
, pp. 649-655
-
-
Goldschlager, N.1
Epstein, A.2
Friedman, P.3
-
38
-
-
7744221160
-
Deaths associated with implantable cardioverter defibrillator failure and deactivation reported in the United States Food and Drug Administration Manufacturer and User Facility Device Experience Database
-
Hauser R.G., and Kallinen L. Deaths associated with implantable cardioverter defibrillator failure and deactivation reported in the United States Food and Drug Administration Manufacturer and User Facility Device Experience Database. Heart Rhythm 4 (2004) 399-405
-
(2004)
Heart Rhythm
, vol.4
, pp. 399-405
-
-
Hauser, R.G.1
Kallinen, L.2
-
39
-
-
3042842810
-
-
Medtronic, Minneapolis (MN) . Accessed Sept 18, 2006
-
Questions and answers about Activa Parkinson's disease therapy (2004), Medtronic, Minneapolis (MN). http://www.medtronic.com/neuro/parkinsons/activa_qa.html . Accessed Sept 18, 2006
-
(2004)
Questions and answers about Activa Parkinson's disease therapy
-
-
-
40
-
-
0030822226
-
High-frequency unilateral thalamic stimulation in the treatment of essential and parkinsonian tremor
-
Koller W., Pahwa R., Busenbark K., et al. High-frequency unilateral thalamic stimulation in the treatment of essential and parkinsonian tremor. Ann Neurol 42 (1997) 292-299
-
(1997)
Ann Neurol
, vol.42
, pp. 292-299
-
-
Koller, W.1
Pahwa, R.2
Busenbark, K.3
-
41
-
-
33947368509
-
-
US Food and Drug Administration. Enterra Therapy System (formerly named Gastric Electrical Stimulation [GES] System). Available at: http://www.fda.gov/cdrh/ode/H990014sum.html. Accessed Sept 18, 2006.
-
-
-
-
42
-
-
33947395518
-
-
Medtronic Entera Therapy 3116. Gastric electrical stimulation system technical manual 2002. Minneapolis (MN): Medtronic Inc; 2002.
-
-
-
-
43
-
-
0032973735
-
Cutaneous electrosurgery in a patient with a deep brain stimulator
-
Weaver J., Kim S.J., Lee M.H., et al. Cutaneous electrosurgery in a patient with a deep brain stimulator. Dermatol Surg 25 (1999) 415-417
-
(1999)
Dermatol Surg
, vol.25
, pp. 415-417
-
-
Weaver, J.1
Kim, S.J.2
Lee, M.H.3
-
44
-
-
3042743274
-
Mohs micrographic surgery in a patient with a deep brain stimulator: a review of the literature on implantable electrical devices
-
Martinelli P.T., Schulze K.E., and Nelson B.R. Mohs micrographic surgery in a patient with a deep brain stimulator: a review of the literature on implantable electrical devices. Dermatol Surg 30 (2004) 1021-1030
-
(2004)
Dermatol Surg
, vol.30
, pp. 1021-1030
-
-
Martinelli, P.T.1
Schulze, K.E.2
Nelson, B.R.3
-
45
-
-
33947380467
-
-
US Food and Drug Administration. Adverse event report. Available at: http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfMAUDE/Detail.cfm?MDR FOI__ID=349768. Accessed Sept 18, 2006.
-
-
-
-
46
-
-
33947426751
-
-
Medtronic Soletra neurostimulator for deep brain stimulation physician and hospital staff manual Rx only. Available at: www.medtronic.com/physician/neurology.html. Accessed January 27, 2007.
-
-
-
-
47
-
-
33947392435
-
-
Medtronic Inc. Medtronic diagnostic and therapies for your patient. Available at: www.medtronic.com/physician/gastroenterology.html. Accessed January 27, 2007.
-
-
-
|