메뉴 건너뛰기




Volumn 1, Issue 4, 2004, Pages 399-405

Deaths associated with implantable cardioverter defibrillator failure and deactivation reported in the United States Food and Drug Administration Manufacturer and User Facility Device Experience Database

Author keywords

Complications; Death; Electromagnetic interference; Implantable cardioverter defibrillator; Malfunction

Indexed keywords

ARTICLE; BIOMEDICAL TECHNOLOGY ASSESSMENT; CONTROLLED STUDY; DEFIBRILLATOR; ELECTIVE SURGERY; ELECTRIC ACCIDENT; FATALITY; FOOD AND DRUG ADMINISTRATION; HEALTH PRACTITIONER; HEART VENTRICLE ARRHYTHMIA; HUMAN; MAGNETIC FIELD; PRIORITY JOURNAL; PULSE GENERATOR; SAFETY; SUDDEN DEATH; TREATMENT CONTRAINDICATION; TREATMENT FAILURE;

EID: 7744221160     PISSN: 15475271     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrthm.2004.05.006     Document Type: Article
Times cited : (95)

References (36)
  • 1
    • 9844224486 scopus 로고    scopus 로고
    • A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias
    • The Antiarrhythmic versus Implantable Defibrillators (AVID) Investigators A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias N Engl J Med 337 1997 1576-1583
    • (1997) N. Engl. J. Med. , vol.337 , pp. 1576-1583
  • 6
    • 7744238912 scopus 로고    scopus 로고
    • Cardiac rhythm management device world markets: Defibrillators, pacemakers, and leads
    • TriMark Publications, November
    • Dooley JF. Cardiac rhythm management device world markets: defibrillators, pacemakers, and leads. TriMark Publications, November 2003.
    • (2003)
    • Dooley, J.F.1
  • 7
    • 7744238914 scopus 로고    scopus 로고
    • Performance of pacemaker and implantable cardioverter defibrillator pulse generators and leads results from the Multicenter Registry
    • H.-F. Tse K.L.F. Lee C.-K. Lau (eds.) Monduzzi Editore Bologna, Italy Clinical pacing and electrophysiology: Results from the Multicenter Registry
    • R. Hauser D. Hayes D. Cannom V. Parsonnet S. Furman A. Epstein S. Vlay G. Tyers M. Irwin A. Almquist S. Song J. Hayes L. Kallinen Performance of pacemaker and implantable cardioverter defibrillator pulse generators and leads results from the Multicenter Registry In: H.-F. Tse K.L.F. Lee C.-K. Lau (eds.) Clinical pacing and electrophysiology 2003 Monduzzi Editore Bologna, Italy 173-179
    • (2003) Clinical Pacing and Electrophysiology , pp. 173-179
    • Hauser, R.1    Hayes, D.2    Cannom, D.3    Parsonnet, V.4    Furman, S.5    Epstein, A.6    Vlay, S.7    Tyers, G.8    Irwin, M.9    Almquist, A.10    Song, S.11    Hayes, J.12    Kallinen, L.13
  • 8
    • 0033388582 scopus 로고    scopus 로고
    • Transvenous cardioverter defibrillator lead malfunction due to terminal connector damage in pectoral implants
    • F. Mera D.B. Delurgia J.J. Langberg E.A. Moss A.R. Leon Transvenous cardioverter defibrillator lead malfunction due to terminal connector damage in pectoral implants Pacing Clin Electrophysiol 22 1999 1797-1801
    • (1999) Pacing Clin. Electrophysiol. , vol.22 , pp. 1797-1801
    • Mera, F.1    Delurgia, D.B.2    Langberg, J.J.3    Moss, E.A.4    Leon, A.R.5
  • 13
    • 0028789379 scopus 로고
    • Incidence of ICD lead related complications during long-term follow-up: Omparison of epicardial and endocardial electrode systems
    • T. Korte W. Jung S. Spehl C. Wolpert R. Moosdorf M. Manz B. Luderitz Incidence of ICD lead related complications during long-term follow-up comparison of epicardial and endocardial electrode systems Pacing Clin Electrophysiol 18 1995 2053-2061
    • (1995) Pacing Clin. Electrophysiol. , vol.18 , pp. 2053-2061
    • Korte, T.1    Jung, W.2    Spehl, S.3    Wolpert, C.4    Moosdorf, R.5    Manz, M.6    Luderitz, B.7
  • 15
    • 0031719076 scopus 로고    scopus 로고
    • Late complications in patients with pectoral defibrillator implants with transvenous defibrillator lead systems: High incidence of insulation breakdown
    • D. Mehta H.M. Nayak M. Singson S. Chao E. Pe J.L. Camunas J.A. Gomes Late complications in patients with pectoral defibrillator implants with transvenous defibrillator lead systems high incidence of insulation breakdown Pacing Clin Electrophysiol 21 1998 1893-1900
    • (1998) Pacing Clin. Electrophysiol. , vol.21 , pp. 1893-1900
    • Mehta, D.1    Nayak, H.M.2    Singson, M.3    Chao, S.4    Pe, E.5    Camunas, J.L.6    Gomes, J.A.7
  • 18
    • 0035040514 scopus 로고    scopus 로고
    • ICD malfunction caused by excessive defibrillation charge time
    • A. de Meester P.H. Gilles ICD malfunction caused by excessive defibrillation charge time Pacing Clin Electrophysiol 24 2001 518-519
    • (2001) Pacing Clin. Electrophysiol. , vol.24 , pp. 518-519
    • de Meester, A.1    Gilles, P.H.2
  • 19
    • 0035690369 scopus 로고    scopus 로고
    • Exploding implantable cardioverter defibrillator
    • M.O. Sweeney Exploding implantable cardioverter defibrillator J Cardiovasc Electrophysiol 12 2001 1422-1424
    • (2001) J. Cardiovasc. Electrophysiol. , vol.12 , pp. 1422-1424
    • Sweeney, M.O.1
  • 20
    • 0024997396 scopus 로고
    • Accidental deactivation of the automatic implantable cardioverter defibrillator
    • C.A. Bonnet J.J. Elson R.N. Fogoros Accidental deactivation of the automatic implantable cardioverter defibrillator Am Heart J 120 1990 696-697
    • (1990) Am. Heart J. , vol.120 , pp. 696-697
    • Bonnet, C.A.1    Elson, J.J.2    Fogoros, R.N.3
  • 21
    • 0036329522 scopus 로고    scopus 로고
    • Unintentional deactivation of implantable cardioverter-defibrillators in health care settings
    • M.J. Rasmussen P.A. Friedman S.C. Hammill R.F. Rea Unintentional deactivation of implantable cardioverter-defibrillators in health care settings Mayo Clin Proc 77 2002 855-859
    • (2002) Mayo Clin. Proc. , vol.77 , pp. 855-859
    • Rasmussen, M.J.1    Friedman, P.A.2    Hammill, S.C.3    Rea, R.F.4
  • 22
    • 0037127438 scopus 로고    scopus 로고
    • "Natural death" of a patient with a deactivated implantable-cardioverter-defibrillator (ICD)?
    • M. Junge J. Weckmuller H. Nagele K. Puschel "Natural death" of a patient with a deactivated implantable-cardioverter-defibrillator (ICD)? Forens Sci Int 125 2002 72-177
    • (2002) Forens. Sci. Int. , vol.125 , pp. 172-177
    • Junge, M.1    Weckmuller, J.2    Nagele, H.3    Puschel, K.4
  • 23
    • 0027183654 scopus 로고
    • Standardized reporting of ICD patient outcome: The report of the North American Society of Pacing and Electrophysiology policy conference
    • S. Kim R.N. Fogoros S. Furman S.J. Connolly K.H. Kuck A.J. Moss Standardized reporting of ICD patient outcome the report of the North American Society of Pacing and Electrophysiology policy conference Pacing Clin Electrophysiol 16 1993 1358-1362
    • (1993) Pacing Clin. Electrophysiol. , vol.16 , pp. 1358-1362
    • Kim, S.1    Fogoros, R.N.2    Furman, S.3    Connolly, S.J.4    Kuck, K.H.5    Moss, A.J.6
  • 24
    • 0032920894 scopus 로고    scopus 로고
    • Sudden death in implantable cardioverter-defibrillator recipients: Clinical context, arrhythmic events and device responses
    • L.A. Pires M.H. Lehman R.T. Steinman J.J. Baga C.D. Schuger Sudden death in implantable cardioverter-defibrillator recipients clinical context, arrhythmic events and device responses J Am Coll Cardiol 33 1999 24-32
    • (1999) J. Am. Coll. Cardiol. , vol.33 , pp. 24-32
    • Pires, L.A.1    Lehman, M.H.2    Steinman, R.T.3    Baga, J.J.4    Schuger, C.D.5
  • 27
    • 7744238915 scopus 로고    scopus 로고
    • Product performance report. Tachyarrhythmia products
    • Medtronic, Inc
    • Product performance report. tachyarrhythmia products. Medtronic, Inc., 2003;13:16-24.
    • (2003) , vol.13 , pp. 16-24
  • 29
    • 0037250453 scopus 로고    scopus 로고
    • Subthreshold test pulses versus low energy shock delivery to estimate high energy lead impedance in implanted cardioverter defibrillator patients
    • D. Vollman L. Luethje D. Zenker S. Domhof C. Unterberg Subthreshold test pulses versus low energy shock delivery to estimate high energy lead impedance in implanted cardioverter defibrillator patients Pacing Clin Electrophysiol 26 2003 457-460
    • (2003) Pacing Clin. Electrophysiol. , vol.26 , pp. 457-460
    • Vollman, D.1    Luethje, L.2    Zenker, D.3    Domhof, S.4    Unterberg, C.5
  • 30
    • 0034010682 scopus 로고    scopus 로고
    • Early detection of lead fractures by painless high voltage lead impedance measurement in a transvenous ICD lead system
    • J. Stevens A.B. Buchwald H. Krieglstein C. Unterberg Early detection of lead fractures by painless high voltage lead impedance measurement in a transvenous ICD lead system J Interv Card Electrophysiol 4 2001 269-272
    • (2001) J. Interv. Card. Electrophysiol. , vol.4 , pp. 269-272
    • Stevens, J.1    Buchwald, A.B.2    Krieglstein, H.3    Unterberg, C.4
  • 32
    • 0035880307 scopus 로고    scopus 로고
    • Recalls and safety alerts involving pacemakers and implantable cardioverter-defibrillator generators
    • W.H. Maisel M.O. Sweeney W.G. Stevenson K.E. Ellison L.M. Epstein Recalls and safety alerts involving pacemakers and implantable cardioverter-defibrillator generators JAMA 286 2001 793-799
    • (2001) JAMA , vol.286 , pp. 793-799
    • Maisel, W.H.1    Sweeney, M.O.2    Stevenson, W.G.3    Ellison, K.E.4    Epstein, L.M.5
  • 33
    • 7744247390 scopus 로고    scopus 로고
    • Guidant ICD lead recall #Z-1144/1145-9. Available at Accessed February 23
    • Guidant ICD lead recall #Z-1144/1145-9. Available at http://www.fda.gov/bbs/topics/ENFORCE/ENF00603.html . Accessed February 23, 2004.
    • (2004)
  • 34
    • 7744247392 scopus 로고    scopus 로고
    • Ventritex ICD pulse generator recall #Z-232/233-7. Available at Accessed February 23
    • Ventritex ICD pulse generator recall #Z-232/233-7. Available at http://www.fda.gov/bbs/topics/ENFORCE/ENF00472.html . Accessed February 23 2004
    • (2004)
  • 35
    • 7744247391 scopus 로고    scopus 로고
    • Medtronic ICD pulse generator recall #Z-261/262-0. Available at Accessed February 23
    • Medtronic ICD pulse generator recall #Z-261/262-0. Available at http://www.fda.gov/bbs/topics/ENFORCE/ENF00629.html . Accessed February 23 2004
    • (2004)
  • 36
    • 0032856728 scopus 로고    scopus 로고
    • Sudden death in recipients of transvenous implantable cardioverter defibrillator systems: Terminal events, predictors, and potential mechanisms
    • L.A. Pires M.L. Hull C.L. Nino L.M. May J.R. Ganji Sudden death in recipients of transvenous implantable cardioverter defibrillator systems terminal events, predictors, and potential mechanisms J Cardiovasc Electrophysiol 10 1999 1049-1056
    • (1999) J. Cardiovasc. Electrophysiol. , vol.10 , pp. 1049-1056
    • Pires, L.A.1    Hull, M.L.2    Nino, C.L.3    May, L.M.4    Ganji, J.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.