메뉴 건너뛰기




Volumn 62, Issue 4, 2005, Pages 485-487

ASGE Technology Status Evaluation Report: Wireless esophageal pH monitoring system

Author keywords

[No Author keywords available]

Indexed keywords

COST; ESOPHAGOSCOPY; ESOPHAGUS; ESOPHAGUS MUCOSA; ESOPHAGUS PH; GASTROESOPHAGEAL REFLUX; GASTROINTESTINAL ENDOSCOPY; HUMAN; LIGHT EMITTING DIODE; MEDICAL INSTRUMENTATION; MEDICAL TECHNOLOGY; PATIENT MONITORING; PRIORITY JOURNAL; SAFETY; SHORT SURVEY;

EID: 25644441845     PISSN: 00165107     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.gie.2005.07.007     Document Type: Article
Times cited : (32)

References (9)
  • 1
    • 0016281523 scopus 로고
    • Twenty-four-hour pH monitoring of the distal esophagus. a quantitative measure of gastroesophageal reflux
    • L.F. Johnson, and T.R. Demeester Twenty-four-hour pH monitoring of the distal esophagus. A quantitative measure of gastroesophageal reflux Am J Gastroenterol 62 1974 325 332
    • (1974) Am J Gastroenterol , vol.62 , pp. 325-332
    • Johnson, L.F.1    Demeester, T.R.2
  • 2
    • 0029980832 scopus 로고    scopus 로고
    • Clinical esophageal pH recording: A technical review for practice guideline development
    • P.J. Kahrilas, and E.M. Quigley Clinical esophageal pH recording: a technical review for practice guideline development Gastroenterology 110 1996 1982 1996
    • (1996) Gastroenterology , vol.110 , pp. 1982-1996
    • Kahrilas, P.J.1    Quigley, E.M.2
  • 3
    • 0032727843 scopus 로고    scopus 로고
    • Effect of ambulatory 24-hour esophageal pH monitoring on reflux-provoking activities
    • R. Fass, R. Hell, and R.E. Sampliner Effect of ambulatory 24-hour esophageal pH monitoring on reflux-provoking activities Dig Dis Sci 44 1999 2263 2269
    • (1999) Dig Dis Sci , vol.44 , pp. 2263-2269
    • Fass, R.1    Hell, R.2    Sampliner, R.E.3
  • 4
    • 0032947654 scopus 로고    scopus 로고
    • The effect of hiatus hernia on gastro-oesophageal junction pressure
    • P.J. Kahrilas, S. Lin, and J. Chen The effect of hiatus hernia on gastro-oesophageal junction pressure Gut 44 1999 476 482
    • (1999) Gut , vol.44 , pp. 476-482
    • Kahrilas, P.J.1    Lin, S.2    Chen, J.3
  • 5
    • 0027276985 scopus 로고
    • Significantly reduced acid detection at 10 centimeters compared to 5 centimeters above lower esophageal sphincter in patients with acid reflux
    • A. Anggiansah, K. Sumboonnanonda, and J. Wang Significantly reduced acid detection at 10 centimeters compared to 5 centimeters above lower esophageal sphincter in patients with acid reflux Am J Gastroenterol 88 1993 842 846
    • (1993) Am J Gastroenterol , vol.88 , pp. 842-846
    • Anggiansah, A.1    Sumboonnanonda, K.2    Wang, J.3
  • 6
    • 25644437348 scopus 로고    scopus 로고
    • Available from: URL: http://www.medtronic.com/neuro/gastro/ambreflux/ bravofaq.html
  • 7
    • 1542329561 scopus 로고    scopus 로고
    • Successful oesophageal pH monitoring with a catheter-free system
    • E.M. Ward, K.R. Devault, and E.P. Bouras Successful oesophageal pH monitoring with a catheter-free system Aliment Pharmacol Ther 19 2004 449 454
    • (2004) Aliment Pharmacol Ther , vol.19 , pp. 449-454
    • Ward, E.M.1    Devault, K.R.2    Bouras, E.P.3
  • 8
    • 0038701753 scopus 로고    scopus 로고
    • Ambulatory esophageal pH monitoring using a wireless system
    • J.E. Pandolfino, J.E. Richter, and T. Ours Ambulatory esophageal pH monitoring using a wireless system Am J Gastroenterol 98 2003 740 749
    • (2003) Am J Gastroenterol , vol.98 , pp. 740-749
    • Pandolfino, J.E.1    Richter, J.E.2    Ours, T.3
  • 9
    • 0037486831 scopus 로고    scopus 로고
    • Clinical evaluation of the Bravo probe: A catheter-free ambulatory esophageal pH monitoring system
    • C.G. Streets, T.R. DeMeester, and J.H. Peter Clinical evaluation of the Bravo probe: a catheter-free ambulatory esophageal pH monitoring system [abstract] Gastroenterology 120 2001 A35
    • (2001) Gastroenterology , vol.120 , pp. 35
    • Streets, C.G.1    Demeester, T.R.2    Peter, J.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.