-
1
-
-
0019163790
-
Cerebral blood flow determination by rapid-sequence computed tomography
-
L. Axel, "Cerebral blood flow determination by rapid-sequence computed tomography," Radiology, vol. 137, pp. 679-686, 1980.
-
(1980)
Radiology
, vol.137
, pp. 679-686
-
-
Axel, L.1
-
2
-
-
0037650168
-
Perfusion CT: A worthwhile enhancement?
-
K. A. Miles, and M. R. Griffiths, "Perfusion CT: a worthwhile enhancement?" Brit. J. Radiol., vol. 76, pp. 220-231, 2003.
-
(2003)
Brit. J. Radiol
, vol.76
, pp. 220-231
-
-
Miles, K.A.1
Griffiths, M.R.2
-
3
-
-
8444236033
-
Comparison of Perfusion Computed Tomography Diffusion-Weighted Magnetic Resonance Imaging Hyperacute Ischemic Stroke
-
S. Bisdas, F. Donnerstag, B. Ahl, I. Bohrer, K. Weissenborn, and H. Becker, "Comparison of Perfusion Computed Tomography Diffusion-Weighted Magnetic Resonance Imaging Hyperacute Ischemic Stroke," J. Comput. Assist. Tomogr., vol. 28, pp. 745-755, 2004.
-
(2004)
J. Comput. Assist. Tomogr
, vol.28
, pp. 745-755
-
-
Bisdas, S.1
Donnerstag, F.2
Ahl, B.3
Bohrer, I.4
Weissenborn, K.5
Becker, H.6
-
4
-
-
33846918981
-
Role of Perfusion Computed Tomography in Preoperative Embolisation of Meningiomas
-
presented at the, Perth, Australia
-
A. Doss, O. Lee, A. Winsor, and M. Bynevelt, "Role of Perfusion Computed Tomography in Preoperative Embolisation of Meningiomas," presented at the 55th RANZCR ASM, Perth, Australia, 2004.
-
(2004)
55th RANZCR ASM
-
-
Doss, A.1
Lee, O.2
Winsor, A.3
Bynevelt, M.4
-
5
-
-
0013920609
-
A model for capillary exchange
-
J. A. Johnson and T. A. Wilson, "A model for capillary exchange," Am. J. Physiol., vol. 210, pp.1299-1303, 1966.
-
(1966)
Am. J. Physiol
, vol.210
, pp. 1299-1303
-
-
Johnson, J.A.1
Wilson, T.A.2
-
6
-
-
0023544649
-
Tracer-kinetic models for measuring cerebral blood flow using externally detected radiotracers
-
K. B. Larson, J. Markham, and M. E. Raichle, "Tracer-kinetic models for measuring cerebral blood flow using externally detected radiotracers," J. Cereb. Bl. Flow Metab., vol. 7, pp. 443-463, 1987.
-
(1987)
J. Cereb. Bl. Flow Metab
, vol.7
, pp. 443-463
-
-
Larson, K.B.1
Markham, J.2
Raichle, M.E.3
-
7
-
-
0037296226
-
A Physiologic Model of Capillary-Tissue Exchange for Dynamic Contrast-Enhanced Imaging of Tumor Microcirculation
-
T. S. Koh, L. H. Cheong, Z. Hou and Y. C. Soh, "A Physiologic Model of Capillary-Tissue Exchange for Dynamic Contrast-Enhanced Imaging of Tumor Microcirculation," IEEE Trans. Biomed. Eng., vol. 50, pp. 159-167, 2003.
-
(2003)
IEEE Trans. Biomed. Eng
, vol.50
, pp. 159-167
-
-
Koh, T.S.1
Cheong, L.H.2
Hou, Z.3
Soh, Y.C.4
-
8
-
-
0001579379
-
Equations for measuring blood flow by external monitoring of radioisotopes
-
K. L. Zierler, "Equations for measuring blood flow by external monitoring of radioisotopes," Circ. Res., vol. 16, pp. 309-321, 1965.
-
(1965)
Circ. Res
, vol.16
, pp. 309-321
-
-
Zierler, K.L.1
-
9
-
-
0032888685
-
CT assessment of cerebral perfusion: Experimental validation and initial clinical experience
-
D. G. Nabavi, A. Cenic, R. A. Craen, A. W. Gelb, J. D. Bennett, R. Kozak and T. Y. Lee, "CT assessment of cerebral perfusion: experimental validation and initial clinical experience," Radiology, vol. 213, pp. 141-149, 1999.
-
(1999)
Radiology
, vol.213
, pp. 141-149
-
-
Nabavi, D.G.1
Cenic, A.2
Craen, R.A.3
Gelb, A.W.4
Bennett, J.D.5
Kozak, R.6
Lee, T.Y.7
-
10
-
-
0032793705
-
Quantitative assessment of cerebral hemodynamics using CT: Stability, accuracy and precision studies in dogs
-
D. G. Nabavi, A. Cenic, J. Dool, R. M. L. Smith, F. Espinosa, R. A. Craen, A. W. Gelb and T. Y. Lee, "Quantitative assessment of cerebral hemodynamics using CT: Stability, accuracy and precision studies in dogs," J. Camp. Assist. Tomogr., vol. 23, pp. 506-515, 1999.
-
(1999)
J. Camp. Assist. Tomogr
, vol.23
, pp. 506-515
-
-
Nabavi, D.G.1
Cenic, A.2
Dool, J.3
Smith, R.M.L.4
Espinosa, F.5
Craen, R.A.6
Gelb, A.W.7
Lee, T.Y.8
-
11
-
-
0344341908
-
Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles
-
E. M. Renkin, "Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles," Am. J. Physiol., vol. 3, pp. 1-41, 1951.
-
(1951)
Am. J. Physiol
, vol.3
, pp. 1-41
-
-
Renkin, E.M.1
-
12
-
-
4143082487
-
Dynamic Contrast-enhanced CT of Intracranial Meningioma: Comparison of Distributed and Compartmental Tracer Kinetic Models-Initial Results
-
L. H. D. Cheong, C. C. T. Lim and T. S. Koh, "Dynamic Contrast-enhanced CT of Intracranial Meningioma: Comparison of Distributed and Compartmental Tracer Kinetic Models-Initial Results", Radiology, vol. 232, pp. 921-930, 2004.
-
(2004)
Radiology
, vol.232
, pp. 921-930
-
-
Cheong, L.H.D.1
Lim, C.C.T.2
Koh, T.S.3
|