메뉴 건너뛰기




Volumn 3, Issue , 2005, Pages 1748-1751

Co-planar PET/CT for small animal imaging

Author keywords

Biomedical nuclear imaging; Gamma detectors; Position sensitive photomultiplier tubes; Positron emission tomography (PET); Small animal imaging

Indexed keywords

BIOMEDICAL NUCLEAR IMAGING; GAMMA DETECTORS; POSITION SENSITIVE PHOTOMULTIPLIER TUBES; SMALL ANIMAL IMAGING;

EID: 33846634885     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2005.1596658     Document Type: Conference Paper
Times cited : (7)

References (15)
  • 1
    • 33846582625 scopus 로고    scopus 로고
    • T. Beyer, P. E. Kinahan, D. W. Townsend, and D. Sashin, - The use of X-ray CT for attenuation correction of PET data, 4, pp.-1577 4, 1994.
    • T. Beyer, P. E. Kinahan, D. W. Townsend, and D. Sashin, "- The use of X-ray CT for attenuation correction of PET data," vol. - 4, pp.-1577 vol.4, 1994.
  • 2
    • 0033349350 scopus 로고    scopus 로고
    • A novel APD-based detector module for multi-modality PET/SPECT/CT
    • A. Saoudi and R. Lecomte, "A novel APD-based detector module for multi-modality PET/SPECT/CT," IEEE Trans in nuclear science, vol. 46, pp. 484, 1999.
    • (1999) IEEE Trans in nuclear science , vol.46 , pp. 484
    • Saoudi, A.1    Lecomte, R.2
  • 3
    • 33846648189 scopus 로고    scopus 로고
    • R. Fontaine, F. Belanger, J. Cadorette, J. D. Leroux, J. P. Martin, J. B. Michaud, J. F. Pratte, S. Robert, and R. Lecomte, -Architecture of a dual-modality, high-resolution, fully digital positron emission tomography/computed tomography (PET/CT) scanner for small animal imaging, 52, pp. - 696, 2005.
    • R. Fontaine, F. Belanger, J. Cadorette, J. D. Leroux, J. P. Martin, J. B. Michaud, J. F. Pratte, S. Robert, and R. Lecomte, "-Architecture of a dual-modality, high-resolution, fully digital positron emission tomography/computed tomography (PET/CT) scanner for small animal imaging," vol. - 52, pp. - 696, 2005.
  • 4
    • 33846560841 scopus 로고    scopus 로고
    • P. Berard, C. M. Pepin, D. Rouleau, J. Cadorette, and R. Lecomte, - CT acquisition using PET detectors and electronics, 52, pp.-637, 2005.
    • P. Berard, C. M. Pepin, D. Rouleau, J. Cadorette, and R. Lecomte, "- CT acquisition using PET detectors and electronics," vol. - 52, pp.-637, 2005.
  • 5
    • 0034088968 scopus 로고    scopus 로고
    • High Resolution X-Ray Computed Tomography: An Emerging Tool for Small Animal Cancer Research
    • M. J. Paulus, "High Resolution X-Ray Computed Tomography: An Emerging Tool for Small Animal Cancer Research," Neoplasia, vol. 2, pp. 62-70, 2000.
    • (2000) Neoplasia , vol.2 , pp. 62-70
    • Paulus, M.J.1
  • 6
    • 33846582125 scopus 로고    scopus 로고
    • Model-based aproach for Beam Hardening Correction and Resolution Measurements in Microtomography
    • Antwerpen: University Antwerpen
    • E. Van de Casteele, "Model-based aproach for Beam Hardening Correction and Resolution Measurements in Microtomography"," in Faculty Wetenschappen, Department Natuurkunde Antwerpen: University Antwerpen, 2004.
    • (2004) Faculty Wetenschappen, Department Natuurkunde
    • Van de Casteele, E.1
  • 7
    • 0033781494 scopus 로고    scopus 로고
    • Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography
    • F. Noo and R. Clackdoyle, "Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography," Phys Med Biol.,vol. 45, pp. 3489-3508, 2000.
    • (2000) Phys Med Biol , vol.45 , pp. 3489-3508
    • Noo, F.1    Clackdoyle, R.2
  • 8
    • 33846620328 scopus 로고    scopus 로고
    • H. Turbell, Cone-beam reconstruction using filtered backprojection, Dept. of electrical engineering, pp. Linköping, Universidad de Linköping, 2001.
    • H. Turbell, "Cone-beam reconstruction using filtered backprojection," Dept. of electrical engineering, pp. Linköping, Universidad de Linköping, 2001.
  • 10
    • 0024627075 scopus 로고
    • Algebraic reconstruction in CT for limited view
    • A. Andersen, "Algebraic reconstruction in CT for limited view," IEEE Trans. Med. Imag., vol. 8, pp. 50-55, 1989.
    • (1989) IEEE Trans. Med. Imag , vol.8 , pp. 50-55
    • Andersen, A.1
  • 11
    • 0021344602 scopus 로고
    • Simultaneous algebraic reconstruction technique (SART): A superior implementation of the art algorithm
    • A. H. Andersen and A. C. Kak, "Simultaneous algebraic reconstruction technique (SART): a superior implementation of the art algorithm," Ultrason Imaging vol. 6, pp. 81-94, 1984.
    • (1984) Ultrason Imaging , vol.6 , pp. 81-94
    • Andersen, A.H.1    Kak, A.C.2
  • 12
    • 0024610693 scopus 로고
    • Analityc three-dimensional image reconstruction using all detected events
    • P. E. Kinahan and W. Rogers, "Analityc three-dimensional image reconstruction using all detected events," IEEE Trans in nuclear science, vol. 36, pp. 964-968, 1990.
    • (1990) IEEE Trans in nuclear science , vol.36 , pp. 964-968
    • Kinahan, P.E.1    Rogers, W.2
  • 14
    • 0020194763 scopus 로고
    • Maximum likelihood estimation for emission tomography
    • L. A. Shepp and Y. Vardi, "Maximum likelihood estimation for emission tomography," IEEE Trans Med Imaging, pp. 113-121, 1982.
    • (1982) IEEE Trans Med Imaging , pp. 113-121
    • Shepp, L.A.1    Vardi, Y.2
  • 15
    • 0023640412 scopus 로고
    • Treatment of axial data in three-dimensional PET
    • M. E. Daube-Witherspoon and G. M., "Treatment of axial data in three-dimensional PET," Jour Nucl Med, vol. 28, 1987.
    • (1987) Jour Nucl Med , vol.28
    • Daube-Witherspoon, M.E.1    M., G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.