Volumn 53, Issue 1, 2005, Pages 177-185

Sensitivity encoding as a means of enhancing the SNR efficiency in steady-state MRI

Author keywords

Contrast enhanced MRA; Parallel MRI; SENSE; SNR efficiency; Steady state gradient echo imaging

Indexed keywords

DEGREES OF FREEDOM (MECHANICS); EFFICIENCY; ENCODING (SYMBOLS); MAGNETIC RESONANCE IMAGING; SIGNAL ENCODING;

EID: 12144280400     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20322     Document Type: Article
Times cited : (33)

References (19)
  • 1
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 5
    • 45949115591 scopus 로고
    • Transverse coherence in rapid FLASH NMR imaging
    • Frahm J, Hänicke W, Merboldt KD. Transverse coherence in rapid FLASH NMR imaging. J Magn Reson 1987;72:307-314.
    • (1987) J Magn Reson , vol.72 , pp. 307-314
    • Frahm, J.1    Hänicke, W.2    Merboldt, K.D.3
  • 7
    • 0025985527 scopus 로고
    • Spoiling of transverse magnetization in steady-state sequences
    • Zur Y, Wood ML, Neuringer LJ. Spoiling of transverse magnetization in steady-state sequences. Magn Reson Med 1991;21:251-263.
    • (1991) Magn Reson Med , vol.21 , pp. 251-263
    • Zur, Y.1    Wood, M.L.2    Neuringer, L.J.3
  • 13
    • 0034538104 scopus 로고    scopus 로고
    • Contrast-enhanced 3D MR angiography with simultaneous acquisition of spatial harmonics: A pilot study
    • Sodickson DK, McKenzie CA, Li W, Wolff S, Manning WJ, Edelman RR. Contrast-enhanced 3D MR angiography with simultaneous acquisition of spatial harmonics: a pilot study. Radiology 2000;217:284-289.
    • (2000) Radiology , vol.217 , pp. 284-289
    • Sodickson, D.K.1    McKenzie, C.A.2    Li, W.3    Wolff, S.4    Manning, W.J.5    Edelman, R.R.6
  • 14
    • 0028113844 scopus 로고
    • The effect of high performance gradients on fast gradient echo imaging
    • Reeder SB, McVeigh ER. The effect of high performance gradients on fast gradient echo imaging. Magn Reson Med 1994;32:612-621.
    • (1994) Magn Reson Med , vol.32 , pp. 612-621
    • Reeder, S.B.1    McVeigh, E.R.2
  • 17
    • 0029805810 scopus 로고    scopus 로고
    • Breath-hold single-dose gadolinium-enhanced MR angiography: Usefulness of a timing examination and MR power injector
    • Earls J, Rofsky N, DeCorato D, Krinsky G, Weinreb J. Breath-hold single-dose gadolinium-enhanced MR angiography: usefulness of a timing examination and MR power injector. Radiology 1996;201:705-710.
    • (1996) Radiology , vol.201 , pp. 705-710
    • Earls, J.1    Rofsky, N.2    DeCorato, D.3    Krinsky, G.4    Weinreb, J.5
  • 19
    • 0036200239 scopus 로고    scopus 로고
    • Utilizing SENSE to achieve lower station sub-millimeter isotropic resolution and minimal venous enhancement in peripheral MR angiography
    • Maki JH, Wilson GJ, Eubank WB, Hoogeveen RM. Utilizing SENSE to achieve lower station sub-millimeter isotropic resolution and minimal venous enhancement in peripheral MR angiography. J Magn Reson Imaging 2002;15:484-491.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 484-491
    • Maki, J.H.1    Wilson, G.J.2    Eubank, W.B.3    Hoogeveen, R.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.