메뉴 건너뛰기




Volumn 30, Issue 6, 2006, Pages 377-381

The role of SPIO-enhanced MRI in the detection of malignant liver lesions

Author keywords

diagnosis; Liver neoplasms; Magnetic resonance imaging; Superparamagnetic iron oxide

Indexed keywords

BIOLOGICAL ORGANS; DIAGNOSIS; IRON OXIDES; STATISTICAL METHODS; SUPERPARAMAGNETISM; TUMORS;

EID: 33750705632     PISSN: 08997071     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinimag.2006.06.001     Document Type: Article
Times cited : (15)

References (24)
  • 1
    • 0032886084 scopus 로고    scopus 로고
    • Liver metastases: comparison of current MR techniques and spiral CT during arterial portography for detection in 20 surgically staged cases
    • Semelka R., Cance W., Marcos H., and Mauro M. Liver metastases: comparison of current MR techniques and spiral CT during arterial portography for detection in 20 surgically staged cases. Radiology 213 (1999) 86-91
    • (1999) Radiology , vol.213 , pp. 86-91
    • Semelka, R.1    Cance, W.2    Marcos, H.3    Mauro, M.4
  • 2
  • 3
    • 0029122716 scopus 로고
    • Detection of liver metastases: comparison of superparamagnetic iron oxide-enhanced and unenhanced MR imaging at 1.5 T with dynamic CT, intraoperative US and percutaneous US
    • Hagspiel K., Neidl K., Eichenberger A., Weder W., and Marincek B. Detection of liver metastases: comparison of superparamagnetic iron oxide-enhanced and unenhanced MR imaging at 1.5 T with dynamic CT, intraoperative US and percutaneous US. Radiology 196 (1995) 471-478
    • (1995) Radiology , vol.196 , pp. 471-478
    • Hagspiel, K.1    Neidl, K.2    Eichenberger, A.3    Weder, W.4    Marincek, B.5
  • 4
    • 0029808352 scopus 로고    scopus 로고
    • Detection of hepatic metastases: ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography
    • Seneterre E., Taourel P., Bouvier Y., Pradel J., Van Beers B., Daures J., Pringot J., Mathieu D., and Bruel J. Detection of hepatic metastases: ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography. Radiology 200 (1996) 785-792
    • (1996) Radiology , vol.200 , pp. 785-792
    • Seneterre, E.1    Taourel, P.2    Bouvier, Y.3    Pradel, J.4    Van Beers, B.5    Daures, J.6    Pringot, J.7    Mathieu, D.8    Bruel, J.9
  • 5
    • 0032956637 scopus 로고    scopus 로고
    • Hepatic lesion detection: comparison of MR imaging after the administration of superparamagnetic iron oxide with dual-phase CT by using alternative-free response receiver operating characteristic analysis
    • Ward J., Naik K., Guithrie J., Wilson D., and Robinson P. Hepatic lesion detection: comparison of MR imaging after the administration of superparamagnetic iron oxide with dual-phase CT by using alternative-free response receiver operating characteristic analysis. Radiology 210 (1999) 459-466
    • (1999) Radiology , vol.210 , pp. 459-466
    • Ward, J.1    Naik, K.2    Guithrie, J.3    Wilson, D.4    Robinson, P.5
  • 8
    • 0032428663 scopus 로고    scopus 로고
    • Detection of colorectal liver metastases: prospective comparison of unenhanced and ferumoxides-enhanced magnetic resonance imaging at 1.5 T, dual phase spiral CT, and spiral CT during arterial portography
    • Lencioni R., Donati F., and Cioni D. Detection of colorectal liver metastases: prospective comparison of unenhanced and ferumoxides-enhanced magnetic resonance imaging at 1.5 T, dual phase spiral CT, and spiral CT during arterial portography. MAGMA 7 (1998) 76-87
    • (1998) MAGMA , vol.7 , pp. 76-87
    • Lencioni, R.1    Donati, F.2    Cioni, D.3
  • 9
    • 0034546354 scopus 로고    scopus 로고
    • Hepatic lesion detection and characterization: value of nonenhanced MR imaging, superparamagnetic iron oxide-enhanced MR imaging, and spiral CT-ROC analysis
    • Reimer P., Jahnke N., Fiebich M., Schima W., Deckers F., Marx C., Holzknecht N., and Saini S. Hepatic lesion detection and characterization: value of nonenhanced MR imaging, superparamagnetic iron oxide-enhanced MR imaging, and spiral CT-ROC analysis. Radiology 217 (2000) 152-158
    • (2000) Radiology , vol.217 , pp. 152-158
    • Reimer, P.1    Jahnke, N.2    Fiebich, M.3    Schima, W.4    Deckers, F.5    Marx, C.6    Holzknecht, N.7    Saini, S.8
  • 10
    • 0028080944 scopus 로고
    • Hepatic tumors: detection and characterization at 1.5 T MR imaging enhanced AMI-25
    • Denys A., Arrive L., Servois V., Dubray B., Najmark D., Sibert A., and Menu Y. Hepatic tumors: detection and characterization at 1.5 T MR imaging enhanced AMI-25. Radiology 193 (1994) 665-669
    • (1994) Radiology , vol.193 , pp. 665-669
    • Denys, A.1    Arrive, L.2    Servois, V.3    Dubray, B.4    Najmark, D.5    Sibert, A.6    Menu, Y.7
  • 11
    • 0033653682 scopus 로고    scopus 로고
    • Detection of hepatic lesions in candidates for surgery: comparison of ferumoxides-enhanced MR imaging and dual-phase helical CT
    • Bluemke D., Paulson E., Choti M., DeSena S., and Clavien P. Detection of hepatic lesions in candidates for surgery: comparison of ferumoxides-enhanced MR imaging and dual-phase helical CT. AJR 175 (2000) 1653-1658
    • (2000) AJR , vol.175 , pp. 1653-1658
    • Bluemke, D.1    Paulson, E.2    Choti, M.3    DeSena, S.4    Clavien, P.5
  • 13
    • 0035157451 scopus 로고    scopus 로고
    • Malignant hepatic tumors detection with ferumoxides-enhanced MR imaging with a 1.5-T system: comparison of four imaging pulse sequences
    • Kanematsu M., Itoh K., Matsuo M., Maetani Y., Ametani F., Kondo H., Kato H., and Hoshi H. Malignant hepatic tumors detection with ferumoxides-enhanced MR imaging with a 1.5-T system: comparison of four imaging pulse sequences. J Magn Reson Imaging 13 (2001) 249-257
    • (2001) J Magn Reson Imaging , vol.13 , pp. 249-257
    • Kanematsu, M.1    Itoh, K.2    Matsuo, M.3    Maetani, Y.4    Ametani, F.5    Kondo, H.6    Kato, H.7    Hoshi, H.8
  • 15
    • 0034076241 scopus 로고    scopus 로고
    • Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT
    • Kondo H., Kanematsu M., Hoshi H., Murakami T., Kim T., Hori M., Matsuo M., and Nakamura H. Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT. AJR 174 (2000) 947-954
    • (2000) AJR , vol.174 , pp. 947-954
    • Kondo, H.1    Kanematsu, M.2    Hoshi, H.3    Murakami, T.4    Kim, T.5    Hori, M.6    Matsuo, M.7    Nakamura, H.8
  • 16
    • 3042709646 scopus 로고    scopus 로고
    • Malignant hepatic tumor detection with ferumoxide-enhanced magnetic resonance imaging: is chemical-shift-selective fat suppression necessary for fast spin-echo sequence?
    • Goshima S., Kanematsu M., Matsuo M., Kondo H., Kako N., Yokohama R., Hoshi H., and Moriyama N. Malignant hepatic tumor detection with ferumoxide-enhanced magnetic resonance imaging: is chemical-shift-selective fat suppression necessary for fast spin-echo sequence?. J Magn Reson Imaging 20 (2004) 75-82
    • (2004) J Magn Reson Imaging , vol.20 , pp. 75-82
    • Goshima, S.1    Kanematsu, M.2    Matsuo, M.3    Kondo, H.4    Kako, N.5    Yokohama, R.6    Hoshi, H.7    Moriyama, N.8
  • 21
    • 0032974388 scopus 로고    scopus 로고
    • Detection of hepatocellular carcinoma arising cirrhotic livers: comparison of gadolinium- and ferumoxides-enhanced MR imaging
    • Tang Y., Yamashita Y., Arakawa A., Namimoto T., Mitsuzaki K., Abe Y., Katahira K., and Takahashi M. Detection of hepatocellular carcinoma arising cirrhotic livers: comparison of gadolinium- and ferumoxides-enhanced MR imaging. AJR 172 (1999) 1547-1554
    • (1999) AJR , vol.172 , pp. 1547-1554
    • Tang, Y.1    Yamashita, Y.2    Arakawa, A.3    Namimoto, T.4    Mitsuzaki, K.5    Abe, Y.6    Katahira, K.7    Takahashi, M.8
  • 22
    • 1542285495 scopus 로고    scopus 로고
    • Preoperative detection of hepatocellular carcinoma: comparison of combined contrast-enhanced MR imaging and combined CT during arterial portography and CT hepatic arteriography
    • Kwak H., Lee J., and Kim C. Preoperative detection of hepatocellular carcinoma: comparison of combined contrast-enhanced MR imaging and combined CT during arterial portography and CT hepatic arteriography. Eur Radiol 14 (2004) 447-457
    • (2004) Eur Radiol , vol.14 , pp. 447-457
    • Kwak, H.1    Lee, J.2    Kim, C.3
  • 24
    • 18244408845 scopus 로고    scopus 로고
    • Ferucarbotran-enhanced MRI versus triple-phase MDCT for the preoperative detection of hepatocellular carcinoma
    • Kim S., Choi D., Kim S., Lim J., Lee W., Kim M., Lim H., and Lee S. Ferucarbotran-enhanced MRI versus triple-phase MDCT for the preoperative detection of hepatocellular carcinoma. AJR 184 (2005) 1069-1076
    • (2005) AJR , vol.184 , pp. 1069-1076
    • Kim, S.1    Choi, D.2    Kim, S.3    Lim, J.4    Lee, W.5    Kim, M.6    Lim, H.7    Lee, S.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.