메뉴 건너뛰기




Volumn 28, Issue 4, 2003, Pages 525-530

Detection and characterization of focal liver lesions using superparamagnetic iron oxide-enhanced magnetic resonance imaging: Comparison between ferumoxides-enhanced T1-weighted imaging and delayed-phase gadolinium-enhanced T1-weighted imaging

Author keywords

Cyst; Liver; Magnetic resonance imaging; Metastasis; Superparamagnetic iron oxide

Indexed keywords

GADOBENIC ACID; GADODIAMIDE; GADOLINIUM; GADOLINIUM PENTETATE MEGLUMINE; GADOTERIDOL; GADOVERSETAMIDE; GADOXETIC ACID; MANGAFODIPIR; SUPERPARAMAGNETIC IRON OXIDE;

EID: 0038005146     PISSN: 09428925     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00261-002-0064-9     Document Type: Article
Times cited : (24)

References (19)
  • 1
    • 0025163295 scopus 로고
    • Iron oxide enhanced imaging of the liver and spleen, review of first 5 years
    • Ferrucci JT, Stark DD. Iron oxide enhanced imaging of the liver and spleen, review of first 5 years. AJR 1990;155:943-950
    • (1990) AJR , vol.155 , pp. 943-950
    • Ferrucci, J.T.1    Stark, D.D.2
  • 2
    • 0034758144 scopus 로고    scopus 로고
    • MR imaging of the liver using gadolinium chelates. MR imaging of the liver I: Techniques and contrast agents
    • Low RN. MR imaging of the liver using gadolinium chelates. MR imaging of the liver I: techniques and contrast agents. Magn Reson Imaging Clin North Am 2001;9:717-741
    • (2001) Magn Reson Imaging Clin North Am , vol.9 , pp. 717-741
    • Low, R.N.1
  • 3
    • 0028020159 scopus 로고
    • Liver MR imaging with iron oxides: Towards consensus and clinical practice
    • Weissleder R. Liver MR imaging with iron oxides: towards consensus and clinical practice. Radiology 1994;193:593-595
    • (1994) Radiology , vol.193 , pp. 593-595
    • Weissleder, R.1
  • 4
    • 84869594070 scopus 로고
    • Clinical results with Resovist: A phase 2 clinical trial
    • Reimer P, Rummeny EJ, Daldrup HE, et al. Clinical results with Resovist: a phase 2 clinical trial. Radiology 1995;195:489-496
    • (1995) Radiology , vol.195 , pp. 489-496
    • Reimer, P.1    Rummeny, E.J.2    Daldrup, H.E.3
  • 5
    • 0027345663 scopus 로고
    • Enhancement of tumor-liver contrast-to-noise ratio with gadobenate dimeglumine in MR imaging of rats
    • Kreft BP, Tanimoto A, Stark DD, et al. Enhancement of tumor-liver contrast-to-noise ratio with gadobenate dimeglumine in MR imaging of rats. J Magn Reson Imaging 1993;3:41-49
    • (1993) J Magn Reson Imaging , vol.3 , pp. 41-49
    • Kreft, B.P.1    Tanimoto, A.2    Stark, D.D.3
  • 6
    • 0029003150 scopus 로고
    • Phase I clinical evaluation of Gd-EOB-DTPA as a hepatobiliary MR contrast agent: Safety, pharmacokinetics, and MR imaging
    • Hamm B, Staks T, Muhler A, et al. Phase I clinical evaluation of Gd-EOB-DTPA as a hepatobiliary MR contrast agent: safety, pharmacokinetics, and MR imaging. Radiology 1995;195:785-792
    • (1995) Radiology , vol.195 , pp. 785-792
    • Hamm, B.1    Staks, T.2    Muhler, A.3
  • 7
    • 0027344890 scopus 로고
    • Mn-DPDP enhancement patterns of hepatocellular lesions on MR images
    • Vogl TJ, Hamm B, Schnell B, et al. Mn-DPDP enhancement patterns of hepatocellular lesions on MR images. J Magn Reson Imaging 1993;3:51-58
    • (1993) J Magn Reson Imaging , vol.3 , pp. 51-58
    • Vogl, T.J.1    Hamm, B.2    Schnell, B.3
  • 8
    • 0025079604 scopus 로고
    • Detection of hepatic metastases: Comparison of contrast-enhanced CT, unenhanced MR imaging, and iron oxide-enhanced MR imaging
    • Fretz CJ, Stark DD, Engelstad BL, et al. Detection of hepatic metastases: Comparison of contrast-enhanced CT, unenhanced MR imaging, and iron oxide-enhanced MR imaging. AJR 1990;155:763-770
    • (1990) AJR , vol.155 , pp. 763-770
    • Fretz, C.J.1    Stark, D.D.2    Engelstad, B.L.3
  • 9
    • 0028046173 scopus 로고
    • Liver metastases: Safety and efficacy of detection with superparamagnetic iron oxide MR imaging
    • Bellin MR, Zaim S, Auberton E, et al. Liver metastases: safety and efficacy of detection with superparamagnetic iron oxide MR imaging. Radiology 1994;193:657-663
    • (1994) Radiology , vol.193 , pp. 657-663
    • Bellin, M.R.1    Zaim, S.2    Auberton, E.3
  • 10
    • 0029671183 scopus 로고    scopus 로고
    • Superparamagnetic iron oxide-enhanced versus gadolinium-enhanced MR imaging for differential diagnosis of focal liver lesions
    • Vogl TJ, Hammerstingl R, Schwarz W, et al. Superparamagnetic iron oxide-enhanced versus gadolinium-enhanced MR imaging for differential diagnosis of focal liver lesions. Radiology 1996;198:881-887
    • (1996) Radiology , vol.198 , pp. 881-887
    • Vogl, T.J.1    Hammerstingl, R.2    Schwarz, W.3
  • 11
    • 0029053490 scopus 로고
    • Benign hepatocellular tumors: MRI after superparamagnetic iron oxide administration
    • Grandin C, Van Beers BE, Robert A, et al. Benign hepatocellular tumors: MRI after superparamagnetic iron oxide administration. J Comput Assist Tomogr 1995;9:412-418
    • (1995) J Comput Assist Tomogr , vol.9 , pp. 412-418
    • Grandin, C.1    Van Beers, B.E.2    Robert, A.3
  • 12
    • 0034089952 scopus 로고    scopus 로고
    • Improved tissue characterization of focal liver lesions with ferumoxide-enhanced T1- and T2-weighted MR imaging
    • Nakayama N, Yamashita Y, Mitsuzaki K, et al. Improved tissue characterization of focal liver lesions with ferumoxide-enhanced T1- and T2-weighted MR imaging. J Magn Reson Imaging 2000;11:647-654
    • (2000) J Magn Reson Imaging , vol.11 , pp. 647-654
    • Nakayama, N.1    Yamashita, Y.2    Mitsuzaki, K.3
  • 13
    • 0032906308 scopus 로고    scopus 로고
    • MRI with superparamagnetic iron oxide: Efficacy in the detection and characterization of focal hepatic lesions
    • Poeckier-Schoeniger C, Koepke J, Gueckel F, et al. MRI with superparamagnetic iron oxide: Efficacy in the detection and characterization of focal hepatic lesions. Magn Reson Imaging 1999;17:383-392
    • (1999) Magn Reson Imaging , vol.17 , pp. 383-392
    • Poeckier-Schoeniger, C.1    Koepke, J.2    Gueckel, F.3
  • 14
    • 0035112361 scopus 로고    scopus 로고
    • Dynamic T1-weighted SPIO enhanced MRI for imaging liver hemangiomas: Preliminary observations
    • Sahani D, Saini S, Sharma R, et al. Dynamic T1-weighted SPIO enhanced MRI for imaging liver hemangiomas: preliminary observations. Abdom Imaging 2001;26:166-170
    • (2001) Abdom Imaging , vol.26 , pp. 166-170
    • Sahani, D.1    Saini, S.2    Sharma, R.3
  • 15
    • 0028032591 scopus 로고    scopus 로고
    • Enhancement of liver hemangiomas on T1-weighted MR SE images by superparamagnetic iron oxide particles
    • Grangier C, Tourniaire J, Mentha G, et al. Enhancement of liver hemangiomas on T1-weighted MR SE images by superparamagnetic iron oxide particles. J Comput Assist Tomogr
    • J Comput Assist Tomogr
    • Grangier, C.1    Tourniaire, J.2    Mentha, G.3
  • 16
    • 0036136741 scopus 로고    scopus 로고
    • Hepatocellular carcinoma: Detection with gadolinium- and SPIO-enhanced MR imaging of the liver
    • Pauleit D, Textor J, Bachmann R, et al. Hepatocellular carcinoma: Detection with gadolinium- and SPIO-enhanced MR imaging of the liver. Radiology 2002;222:73-80
    • (2002) Radiology , vol.222 , pp. 73-80
    • Pauleit, D.1    Textor, J.2    Bachmann, R.3
  • 17
    • 0032974388 scopus 로고    scopus 로고
    • Detection of hepatocellular carcinoma arising in cirrhotic livers: Comparison of gadolinium- and SPIO-enhanced MR imaging
    • Tang Y, Yamashita Y, Arakawa A, et al. Detection of hepatocellular carcinoma arising in cirrhotic livers: comparison of gadolinium- and SPIO-enhanced MR imaging. AJR 1999;172:1547-1554
    • (1999) AJR , vol.172 , pp. 1547-1554
    • Tang, Y.1    Yamashita, Y.2    Arakawa, A.3
  • 18
    • 0033919450 scopus 로고    scopus 로고
    • Hepatocellular carcinoma in the cirrhotic liver: Double-contrast MR imaging for diagnosis
    • Ward J, Guthrie JA, Scott DJ, et al. Hepatocellular carcinoma in the cirrhotic liver: double-contrast MR imaging for diagnosis. Radiology 2000;216:154-162
    • (2000) Radiology , vol.216 , pp. 154-162
    • Ward, J.1    Guthrie, J.A.2    Scott, D.J.3
  • 19
    • 0031806405 scopus 로고    scopus 로고
    • Sequential use of ferumoxide particles and gadolinium chelate for the evaluation of focal liver lesions on MRI
    • Semelka RC, Lee JKT, Worawattanakul S, et al. Sequential use of ferumoxide particles and gadolinium chelate for the evaluation of focal liver lesions on MRI. J Magn Reson Imaging 1998;8:670-674
    • (1998) J Magn Reson Imaging , vol.8 , pp. 670-674
    • Semelka, R.C.1    Lee, J.K.T.2    Worawattanakul, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.