메뉴 건너뛰기




Volumn 24, Issue 5, 2006, Pages 995-1004

Brain hydrodynamics study by phase-contrast magnetic resonance imaging transcranial color Doppler

Author keywords

Cerebral blood flow; Cerebral hydrodynamics; Cerebrospinal fluid; Doppler measurements; Phase contrast magnetic resonance imaging

Indexed keywords

ADULT; ARTICLE; BLOOD FLOW VELOCITY; BLOOD VOLUME; BRAIN BLOOD FLOW; CEREBROSPINAL FLUID FLOW; DOPPLER ECHOGRAPHY; ECHOENCEPHALOGRAPHY; FEMALE; HUMAN; HUMAN EXPERIMENT; HYDRODYNAMICS; IMAGE ANALYSIS; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PHASE CONTRAST NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 33750437269     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20722     Document Type: Article
Times cited : (61)

References (46)
  • 1
    • 0020394689 scopus 로고
    • Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries
    • Aaslid R, Markwalder TM, Nomes H. Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg 1982;57:769-774.
    • (1982) J Neurosurg , vol.57 , pp. 769-774
    • Aaslid, R.1    Markwalder, T.M.2    Nomes, H.3
  • 2
    • 0025853771 scopus 로고
    • Imaging of the basal cerebral arteries and measurement of blood velocity in adults by using transcranial real-time color flow Doppler sonography
    • Tsuchiya T, Yasaka M, Yamaguchi T, Kimura K, Omae T. Imaging of the basal cerebral arteries and measurement of blood velocity in adults by using transcranial real-time color flow Doppler sonography. AJNR Am J Neuroradiol 1991;12:497-502.
    • (1991) AJNR Am J Neuroradiol , vol.12 , pp. 497-502
    • Tsuchiya, T.1    Yasaka, M.2    Yamaguchi, T.3    Kimura, K.4    Omae, T.5
  • 3
    • 0036084560 scopus 로고    scopus 로고
    • Vertebrobasilar transcranial color-coded duplex ultrasonography: Improvement with echo enhancement
    • Stolz E, Nuckel M, Mendes I, Gerriets T, Kaps M. Vertebrobasilar transcranial color-coded duplex ultrasonography: improvement with echo enhancement. AJNR Am J Neuroradiol 2002;23:1051-1054.
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 1051-1054
    • Stolz, E.1    Nuckel, M.2    Mendes, I.3    Gerriets, T.4    Kaps, M.5
  • 4
    • 0032191113 scopus 로고    scopus 로고
    • Blood-flow velocities and their relationships in carotid and middle cerebral arteries
    • Nagai Y, Kemper MK, Earley CJ, Metter EJ. Blood-flow velocities and their relationships in carotid and middle cerebral arteries. Ultrasound Med Biol 1998;24:1131-1136.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 1131-1136
    • Nagai, Y.1    Kemper, M.K.2    Earley, C.J.3    Metter, E.J.4
  • 5
    • 0032958718 scopus 로고    scopus 로고
    • Transcranial color Doppler sonography of basal cerebral arteries in 182 healthy subjects: Age and sex variability and normal reference values for blood flow parameters
    • Krejza J, Mariak Z, Waleckl J, Szydlik P, Lewko J, Ustymowicz A. Transcranial color Doppler sonography of basal cerebral arteries in 182 healthy subjects: age and sex variability and normal reference values for blood flow parameters. AJR Am J Roentgenol 1999;172:213-218.
    • (1999) AJR Am J Roentgenol , vol.172 , pp. 213-218
    • Krejza, J.1    Mariak, Z.2    Waleckl, J.3    Szydlik, P.4    Lewko, J.5    Ustymowicz, A.6
  • 7
    • 0028226718 scopus 로고
    • A validation study on the intraobserver reproducibility of transcranial color-coded duplex sonography velocity measurements
    • Baumgartner RW, Mathis J, Sturzenegger M, Mattle HP. A validation study on the intraobserver reproducibility of transcranial color-coded duplex sonography velocity measurements. Ultrasound Med Biol 1994;20:233-237.
    • (1994) Ultrasound Med Biol , vol.20 , pp. 233-237
    • Baumgartner, R.W.1    Mathis, J.2    Sturzenegger, M.3    Mattle, H.P.4
  • 8
    • 0034811054 scopus 로고    scopus 로고
    • Interobserver and intraobserver reliability of venous transcranial colorcoded flow velocity measurements
    • Stolz E, Babacan SS, Bodeker RH, Gerriets T, Kaps M. Interobserver and intraobserver reliability of venous transcranial colorcoded flow velocity measurements. J Neuroimaging 2001;11:385-392.
    • (2001) J Neuroimaging , vol.11 , pp. 385-392
    • Stolz, E.1    Babacan, S.S.2    Bodeker, R.H.3    Gerriets, T.4    Kaps, M.5
  • 9
    • 0033059560 scopus 로고    scopus 로고
    • Success rate of transcranial color-coded duplex ultrasonography in visualizing the basal cerebral arteries in vascular patients over 60 years of age
    • Hoksbergen AW, Legemate DA, Ubbink DT, Jacobs MJ. Success rate of transcranial color-coded duplex ultrasonography in visualizing the basal cerebral arteries in vascular patients over 60 years of age. Stroke 1999;30:1450-1455.
    • (1999) Stroke , vol.30 , pp. 1450-1455
    • Hoksbergen, A.W.1    Legemate, D.A.2    Ubbink, D.T.3    Jacobs, M.J.4
  • 10
    • 0020340302 scopus 로고
    • A flow velocity zeugmatographic interlace for NMR imaging in humans
    • Moran PR. A flow velocity zeugmatographic interlace for NMR imaging in humans. Magn Reson Imaging 1982;1:197-203.
    • (1982) Magn Reson Imaging , vol.1 , pp. 197-203
    • Moran, P.R.1
  • 11
    • 0025222655 scopus 로고
    • Fourier analysis of cerebrospinal fluid flow velocities: MR imaging study
    • The Scandinavian Flow Group
    • Thomsen C, Stahlberg F, Stubgaard M, Nordell B. Fourier analysis of cerebrospinal fluid flow velocities: MR imaging study. The Scandinavian Flow Group. Radiology 1990;177:659-665.
    • (1990) Radiology , vol.177 , pp. 659-665
    • Thomsen, C.1    Stahlberg, F.2    Stubgaard, M.3    Nordell, B.4
  • 12
    • 0023223706 scopus 로고
    • Human brain motion and cerebrospinal fluid circulation demonstrated with MR velocity imaging
    • Feinberg DA, Mark AS. Human brain motion and cerebrospinal fluid circulation demonstrated with MR velocity imaging. Radiology 1987;163:793-799.
    • (1987) Radiology , vol.163 , pp. 793-799
    • Feinberg, D.A.1    Mark, A.S.2
  • 13
    • 0028069504 scopus 로고
    • Blood flow in major cerebral arteries measured by phase-contrast cine MR
    • Enzmann DR, Ross MR, Marks MP, Pelc NJ. Blood flow in major cerebral arteries measured by phase-contrast cine MR. AJNR Am J Neuroradiol 1994;15:123-129.
    • (1994) AJNR Am J Neuroradiol , vol.15 , pp. 123-129
    • Enzmann, D.R.1    Ross, M.R.2    Marks, M.P.3    Pelc, N.J.4
  • 14
    • 0029399154 scopus 로고
    • Validation of volume flow measurements with cine phase-contrast MR imaging for peripheral arterial waveforms
    • McCauley TR, Pena CS, Holland CK, Price TB, Gore JC. Validation of volume flow measurements with cine phase-contrast MR imaging for peripheral arterial waveforms. J Magn Reson Imaging 1995;5:663-668.
    • (1995) J Magn Reson Imaging , vol.5 , pp. 663-668
    • McCauley, T.R.1    Pena, C.S.2    Holland, C.K.3    Price, T.B.4    Gore, J.C.5
  • 16
    • 0028435459 scopus 로고
    • MR imaging of cerebrospinal fluid dynamics in health and disease. On the vascular pathogenesis of communicating hydrocephalus and benign intracranial hypertension
    • Greitz D, Hannerz J, Rahn T, Bolander H, Ericsson A. MR imaging of cerebrospinal fluid dynamics in health and disease. On the vascular pathogenesis of communicating hydrocephalus and benign intracranial hypertension. Acta Radiol 1994;35:204-211.
    • (1994) Acta Radiol , vol.35 , pp. 204-211
    • Greitz, D.1    Hannerz, J.2    Rahn, T.3    Bolander, H.4    Ericsson, A.5
  • 17
    • 0027361074 scopus 로고
    • Cerebrospinal fluid flow measured by phase-contrast cine MR
    • discussion 1309-1310
    • Enzmann DR, Pelc NJ. Cerebrospinal fluid flow measured by phase-contrast cine MR. AJNR Am J Neuroradiol 1993;14:1301-1307; discussion 1309-1310.
    • (1993) AJNR Am J Neuroradiol , vol.14 , pp. 1301-1307
    • Enzmann, D.R.1    Pelc, N.J.2
  • 18
    • 0034951649 scopus 로고    scopus 로고
    • Cerebrospinal fluid dynamics and relation with blood flow: A magnetic resonance study with semiautomated cerebrospinal fluid segmentation
    • Balédent O. Henry-Feugeas M-C, Idy-Peretti I. Cerebrospinal fluid dynamics and relation with blood flow: a magnetic resonance study with semiautomated cerebrospinal fluid segmentation. Invest Radiol 2001;36:368-377.
    • (2001) Invest Radiol , vol.36 , pp. 368-377
    • Balédent, O.1    Henry-Feugeas, M.-C.2    Idy-Peretti, I.3
  • 20
    • 0037407672 scopus 로고    scopus 로고
    • PUBS: Pulsatility-based segmentation of lumens conducting non-steady flow
    • Alperin N, Lee SH. PUBS: pulsatility-based segmentation of lumens conducting non-steady flow. Magn Reson Med 2003;49:934-944.
    • (2003) Magn Reson Med , vol.49 , pp. 934-944
    • Alperin, N.1    Lee, S.H.2
  • 22
    • 0033794557 scopus 로고    scopus 로고
    • Quantification of blood flow in the middle cerebral artery with phase-contrast MR imaging
    • Stock KW, Wetzel SG, Lyrer PA, Radu EW. Quantification of blood flow in the middle cerebral artery with phase-contrast MR imaging. Eur Radiol 2000;10:1795-1800.
    • (2000) Eur Radiol , vol.10 , pp. 1795-1800
    • Stock, K.W.1    Wetzel, S.G.2    Lyrer, P.A.3    Radu, E.W.4
  • 23
    • 0030922875 scopus 로고    scopus 로고
    • Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: In vitro and in vivo validation
    • Lee VS, Spritzer CE, Carroll BA, et al. Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: in vitro and in vivo validation. AJR Am J Roentgenol 1997;169:1125-1131.
    • (1997) AJR Am J Roentgenol , vol.169 , pp. 1125-1131
    • Lee, V.S.1    Spritzer, C.E.2    Carroll, B.A.3
  • 24
    • 0028852729 scopus 로고
    • Carotid artery stenosis: Clinical efficacy of MR phase-contrast flow quantification as an adjunct to MR angiography
    • Vanninen RL, Manninen HI, Partanen PL, Vainio PA, Soimakallio S. Carotid artery stenosis: clinical efficacy of MR phase-contrast flow quantification as an adjunct to MR angiography. Radiology 1995;194:459-467.
    • (1995) Radiology , vol.194 , pp. 459-467
    • Vanninen, R.L.1    Manninen, H.I.2    Partanen, P.L.3    Vainio, P.A.4    Soimakallio, S.5
  • 25
    • 0032238812 scopus 로고    scopus 로고
    • Cine phase-contrast MR imaging in normal pressure hydrocephalus patients: Relation to surgical outcome
    • Egeler-Peerdeman SM, Barkhof F, Walchenbach R, Valk J. Cine phase-contrast MR imaging in normal pressure hydrocephalus patients: relation to surgical outcome. Acta Neurochir Suppl 1998;71:340-342.
    • (1998) Acta Neurochir Suppl , vol.71 , pp. 340-342
    • Egeler-Peerdeman, S.M.1    Barkhof, F.2    Walchenbach, R.3    Valk, J.4
  • 26
    • 0030028170 scopus 로고    scopus 로고
    • Normal-pressure hydrocephalus: Evaluation with cerebrospinal fluid flow measurements at MR imaging
    • Bradley W. Scalzo D. Queralt J, Nitz WN, Atkinson DJ, Wong P. Normal-pressure hydrocephalus: evaluation with cerebrospinal fluid flow measurements at MR imaging. Radiology 1996;198:523-529.
    • (1996) Radiology , vol.198 , pp. 523-529
    • Bradley, W.1    Scalzo, D.2    Queralt, J.3    Nitz, W.N.4    Atkinson, D.J.5    Wong, P.6
  • 27
    • 0036523920 scopus 로고    scopus 로고
    • Measurement of cerebrospinal fluid flow at the cerebral aqueduct by use of phase-contrast magnetic resonance imaging: Technique validation and utility in diagnosing idiopathic normal pressure hydrocephalus
    • discussion 543-534
    • Luetrner PH, Huston J, Friedman JA, et al. Measurement of cerebrospinal fluid flow at the cerebral aqueduct by use of phase-contrast magnetic resonance imaging: technique validation and utility in diagnosing idiopathic normal pressure hydrocephalus. Neurosurgery 2002;50:534-543: discussion 543-534.
    • (2002) Neurosurgery , vol.50 , pp. 534-543
    • Luetrner, P.H.1    Huston, J.2    Friedman, J.A.3
  • 28
    • 0035092175 scopus 로고    scopus 로고
    • Cerebrospinal fluid flow waveforms: MR analysis in chronic adult hydrocephalus
    • Henry-Feugeas MC, Idy-Peretti I, Baledent O, et al. Cerebrospinal fluid flow waveforms: MR analysis in chronic adult hydrocephalus. Invest Radiol 2001;36:146-154.
    • (2001) Invest Radiol , vol.36 , pp. 146-154
    • Henry-Feugeas, M.C.1    Idy-Peretti, I.2    Baledent, O.3
  • 29
    • 0000552791 scopus 로고    scopus 로고
    • The pathogenesis and hemodynamics of hydrocephalus
    • Greitz D, Greitz T. the pathogenesis and hemodynamics of hydrocephalus. Int J Neuroradiol 1997;3:367-375.
    • (1997) Int J Neuroradiol , vol.3 , pp. 367-375
    • Greitz, D.1    Greitz, T.2
  • 31
    • 0346789097 scopus 로고    scopus 로고
    • Relationship between cerebrospinal fluid and blood dynamics in healthy volunteers' and patients with communicating hydrocephalus
    • Balédent O, Gondry-Jouet C, Meyer ME, et al. Relationship between cerebrospinal fluid and blood dynamics in healthy volunteers' and patients with communicating hydrocephalus. Invest Radiol 2004;39:45-55.
    • (2004) Invest Radiol , vol.39 , pp. 45-55
    • Balédent, O.1    Gondry-Jouet, C.2    Meyer, M.E.3
  • 32
    • 0036677919 scopus 로고    scopus 로고
    • Vascular hydraulics associated with idiopathic and secondary intracranial hypertension
    • Bateman GA. Vascular hydraulics associated with idiopathic and secondary intracranial hypertension. AJNR Am J Neuroradiol 2002;23:1180-1186.
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 1180-1186
    • Bateman, G.A.1
  • 33
    • 0029991025 scopus 로고    scopus 로고
    • Hemodynamically independent analysis of cerebrospinal fluid and brain motion observed with dynamic phase contrast MRI
    • Alperin N, Vikingstad EM, Gomez-Anson B, Levin DN. Hemodynamically independent analysis of cerebrospinal fluid and brain motion observed with dynamic phase contrast MRI. Magn Reson Med 1996;35:741-754.
    • (1996) Magn Reson Med , vol.35 , pp. 741-754
    • Alperin, N.1    Vikingstad, E.M.2    Gomez-Anson, B.3    Levin, D.N.4
  • 34
    • 0017894233 scopus 로고
    • A nonlinear analysis of the cerebrospinal fluid system and intracranial pressure dynamics
    • Marmarou A, Shulman K, Rosende RM, A nonlinear analysis of the cerebrospinal fluid system and intracranial pressure dynamics. J Neurosurg 1978;48:332-344.
    • (1978) J Neurosurg , vol.48 , pp. 332-344
    • Marmarou, A.1    Shulman, K.2    Rosende, R.M.3
  • 35
    • 0033693419 scopus 로고    scopus 로고
    • MR-Intracranial pressure (ICP): A method to measure intracranial elastance and pressure noninvasively by means of MR imaging; baboon and human study
    • Alperin NJ, Lee SH, Loth F, Raksin PB, Lichtor T. MR-Intracranial pressure (ICP): a method to measure intracranial elastance and pressure noninvasively by means of MR imaging; baboon and human study. Radiology 2000;217:877-885.
    • (2000) Radiology , vol.217 , pp. 877-885
    • Alperin, N.J.1    Lee, S.H.2    Loth, F.3    Raksin, P.B.4    Lichtor, T.5
  • 36
    • 0030984266 scopus 로고    scopus 로고
    • A simple mathematical model of the interaction between intracranial pressure and cerebral hemodynamics
    • Ursino M, Lodi CA, A simple mathematical model of the interaction between intracranial pressure and cerebral hemodynamics. J Appl Physiol 1997;82;1256-1269.
    • (1997) J Appl Physiol , vol.82 , pp. 1256-1269
    • Ursino, M.1    Lodi, C.A.2
  • 39
    • 0036791843 scopus 로고    scopus 로고
    • Detection of carotid artery stenosis by in vivo duplex ultrasound; correlation with planimetric measurements of the corresponding postmortem specimens
    • Schulte-Altedomeburg G, Droste DW, Felszeghy S, et al. Detection of carotid artery stenosis by in vivo duplex ultrasound; correlation with planimetric measurements of the corresponding postmortem specimens. Stroke 2002;33:2402-2407,
    • (2002) Stroke , vol.33 , pp. 2402-2407
    • Schulte-Altedomeburg, G.1    Droste, D.W.2    Felszeghy, S.3
  • 40
    • 0036584937 scopus 로고    scopus 로고
    • Cardiovascular flow measurement with phase-contrast MR imaging: Basic facts and implementation
    • Lotz J, Meler C, Leppert A, Galanski M. Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation. Radiographics 2002;22:651-671.
    • (2002) Radiographics , vol.22 , pp. 651-671
    • Lotz, J.1    Meler, C.2    Leppert, A.3    Galanski, M.4
  • 41
    • 0030065280 scopus 로고    scopus 로고
    • Accuracy of maximum velocity estimates made using Doppler ultrasound systems
    • Hoskins PR. Accuracy of maximum velocity estimates made using Doppler ultrasound systems, Br J Radiol 1996;69:172-177.
    • (1996) Br J Radiol , vol.69 , pp. 172-177
    • Hoskins, P.R.1
  • 42
    • 0026750480 scopus 로고
    • Factors influencing the accuracy and precision of velocity-encoded phase imaging
    • Buonocore MH, Bogren H. Factors influencing the accuracy and precision of velocity-encoded phase imaging, Magn Reson Med 1992;26:141-154.
    • (1992) Magn Reson Med , vol.26 , pp. 141-154
    • Buonocore, M.H.1    Bogren, H.2
  • 43
    • 0031677029 scopus 로고    scopus 로고
    • Effect of age on cerebral blood flow; measurement with ungated two-dimensional phase-contrast MR angiography in 250 adults
    • Buijs PC, Krabbe-Hartkamp MJ, Bakker CJ, et al. Effect of age on cerebral blood flow; measurement with ungated two-dimensional phase-contrast MR angiography In 250 adults. Radiology 1998;209:667-674.
    • (1998) Radiology , vol.209 , pp. 667-674
    • Buijs, P.C.1    Krabbe-Hartkamp, M.J.2    Bakker, C.J.3
  • 44
    • 0021333894 scopus 로고
    • Intracranial venous sinus hypertension: Cause or consequence of hydrocephalus in infants?
    • Sainte-Rose C, La Combe J, Pierre-Kahn A, Renier D, Hirsch JF, Intracranial venous sinus hypertension: cause or consequence of hydrocephalus in infants? J Neurosurg 1984;60:727-736.
    • (1984) J Neurosurg , vol.60 , pp. 727-736
    • Sainte-Rose, C.1    La Combe, J.2    Pierre-Kahn, A.3    Renier, D.4    Hirsch, J.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.