메뉴 건너뛰기




Volumn 15, Issue 5, 2006, Pages 553-557

Fretting fatigue studies of titanium nitride-coated biomedical titanium alloys

Author keywords

Biomaterials; Fretting fatigue; Physical vapor deposition (PVD) coatings; Titanium alloys

Indexed keywords

BIOLOGICAL MATERIALS; DELAMINATION; HIP PROSTHESES; PHYSICAL VAPOR DEPOSITION; TITANIUM ALLOYS; TRIBOLOGY;

EID: 33750156208     PISSN: 10599495     EISSN: None     Source Type: Journal    
DOI: 10.1361/105994906X136115     Document Type: Article
Times cited : (17)

References (16)
  • 2
    • 15244344080 scopus 로고    scopus 로고
    • Development and pharmacological characterization of a rat model of osteoarthritis pain
    • J.D. Pomonis, J.M. Boulet, S.L. Gottshall, S. Phillips, R. Sellers, T. Bunton, and K. Walker, Development and Pharmacological Characterization of a Rat Model of Osteoarthritis Pain, Pain, 2005, 114(3), p 339-346
    • (2005) Pain , vol.114 , Issue.3 , pp. 339-346
    • Pomonis, J.D.1    Boulet, J.M.2    Gottshall, S.L.3    Phillips, S.4    Sellers, R.5    Bunton, T.6    Walker, K.7
  • 4
    • 0038542978 scopus 로고    scopus 로고
    • Orthopedic implant fretting corrosion
    • N.J. Hallab and J.J. Jacobs, Orthopedic Implant Fretting Corrosion, Corros. Rev., 2003, 21, p 183-214
    • (2003) Corros. Rev. , vol.21 , pp. 183-214
    • Hallab, N.J.1    Jacobs, J.J.2
  • 5
    • 0034317060 scopus 로고    scopus 로고
    • Fatigue of biomaterials: A review
    • S.H. Teoh, Fatigue of Biomaterials: A Review, Int. J. Fatigue, 2000, 22, p 825-837
    • (2000) Int. J. Fatigue , vol.22 , pp. 825-837
    • Teoh, S.H.1
  • 6
    • 0032170254 scopus 로고    scopus 로고
    • Review: Titanium alloys in total joint replacement - A material science perspective
    • M. Long and H.J. Rack, Review: Titanium Alloys in Total Joint Replacement - A Material Science Perspective, Biomaterials, 1998, 19, p 1621-1639
    • (1998) Biomaterials , vol.19 , pp. 1621-1639
    • Long, M.1    Rack, H.J.2
  • 7
    • 0031464983 scopus 로고    scopus 로고
    • Mechanism of fretting fatigue of titanium alloys
    • R.A. Antoniou and T.C. Radtke, Mechanism of Fretting Fatigue of Titanium Alloys, Mater. Sci. Eng. A, 1997, 237, p 229-240
    • (1997) Mater. Sci. Eng. A , vol.237 , pp. 229-240
    • Antoniou, R.A.1    Radtke, T.C.2
  • 8
    • 0037805083 scopus 로고    scopus 로고
    • Failures of stainless steel orthopedic devices: Causes and remedies
    • U. Kamachi Mudali, T.M. Sridhar, N. Eliaz, and B. Raj, Failures of Stainless Steel Orthopedic Devices: Causes and Remedies, Corros. Rev., 2003, 21, p 231-267
    • (2003) Corros. Rev. , vol.21 , pp. 231-267
    • Mudali, U.K.1    Sridhar, T.M.2    Eliaz, N.3    Raj, B.4
  • 9
  • 10
    • 0034087518 scopus 로고    scopus 로고
    • Titanium nitride coatings on surgical titanium alloys produced by a powder immersion reaction assisted coating method: Residual stresses and fretting behavior
    • A. Shenhar, I. Gotman, S. Radin, P. Ducheyne, and E.Y. Gutmanas, Titanium Nitride Coatings on Surgical Titanium Alloys Produced by a Powder Immersion Reaction Assisted Coating Method: Residual Stresses and Fretting Behavior, Surf. Coat. Technol., 2000, 126, p 210-218
    • (2000) Surf. Coat. Technol. , vol.126 , pp. 210-218
    • Shenhar, A.1    Gotman, I.2    Radin, S.3    Ducheyne, P.4    Gutmanas, E.Y.5
  • 11
    • 0036147110 scopus 로고    scopus 로고
    • Mechanical properties of TiN thin film coatings on 304 stainless steel substrates
    • W.-J. Chou, G.-P. Yu, and J.-H. Huang, Mechanical Properties of TiN Thin Film Coatings on 304 Stainless Steel Substrates, Surf. Coat. Technol., 2002, 149, p 7-13
    • (2002) Surf. Coat. Technol. , vol.149 , pp. 7-13
    • Chou, W.-J.1    Yu, G.-P.2    Huang, J.-H.3
  • 12
    • 19244379197 scopus 로고    scopus 로고
    • Evaluation of mechanical properties of ceramic coatings on a metal substrate
    • T. Ohmura and S. Matsuoka, Evaluation of Mechanical Properties of Ceramic Coatings on a Metal Substrate, Surf. Coat. Technol., 2003, 169, p 728-731
    • (2003) Surf. Coat. Technol. , vol.169 , pp. 728-731
    • Ohmura, T.1    Matsuoka, S.2
  • 13
    • 0038115314 scopus 로고    scopus 로고
    • Surface characterization of passive film formed on nitrogen ion implanted TJ-6Al-4V and Ti-6Al-7Nb alloys using SIMS
    • L. Thair, U.K. Mudali, S. Rajagopalan, R. Asokamani, and B. Raj, Surface Characterization of Passive Film Formed on Nitrogen Ion Implanted TJ-6Al-4V and Ti-6Al-7Nb Alloys Using SIMS, Corros. Sci., 2003, 45, p 1951-1967
    • (2003) Corros. Sci. , vol.45 , pp. 1951-1967
    • Thair, L.1    Mudali, U.K.2    Rajagopalan, S.3    Asokamani, R.4    Raj, B.5
  • 14
    • 0034980299 scopus 로고    scopus 로고
    • Corrosion behavior of titanium nitride coated Ni-Ti shape memory surgical alloy
    • D. Starosvetsky and I. Gotman, Corrosion Behavior of Titanium Nitride Coated Ni-Ti Shape Memory Surgical Alloy, Biomaterials, 2001, 22, p 1853-1859
    • (2001) Biomaterials , vol.22 , pp. 1853-1859
    • Starosvetsky, D.1    Gotman, I.2
  • 15
    • 1842787388 scopus 로고    scopus 로고
    • Environmental effect on fretting of metallic materials for orthopedic implants
    • L. Duisabeau, P. Combrade, and B. Forest, Environmental Effect on Fretting of Metallic Materials for Orthopedic Implants, Wear, 2004, 256, p 805-816
    • (2004) Wear , vol.256 , pp. 805-816
    • Duisabeau, L.1    Combrade, P.2    Forest, B.3
  • 16
    • 2942711910 scopus 로고    scopus 로고
    • Effect of microstructure on fretting fatigue and sliding wear of highly workable titanium alloy, Ti-4.5Al-3V-2Mo-2Fe
    • J. Takeda, M. Niinomi, T. Akahori, and Gunawarman, Effect of Microstructure on Fretting Fatigue and Sliding Wear of Highly Workable Titanium Alloy, Ti-4.5Al-3V-2Mo-2Fe, Int. J. Fatigue, 2004, 26, p 1003-1015
    • (2004) Int. J. Fatigue , vol.26 , pp. 1003-1015
    • Takeda, J.1    Niinomi, M.2    Akahori, T.3    Gunawarman4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.