Volumn 169-170, Issue , 2003, Pages 728-731

Evaluation of mechanical properties of ceramic coatings on a metal substrate

Author keywords

Adhesion; Interface; Nanoindentation; Tensile test; Titanium nitride

Indexed keywords

INTERFACES (MATERIALS); PLASTIC DEFORMATION; STATISTICAL METHODS; TENSILE TESTING;

EID: 19244379197     PISSN: 02578972     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0257-8972(03)00210-X     Document Type: Article
Times cited : (29)

References (18)
  • 3
    • 0037801532 scopus 로고
    • V. Ashworth, W. Grant, R. Procter (Eds.), Oxford: Pergamon Press
    • Pethica J.B. Ashworth V. Grant W. Procter R. Ion Implantation into Metals 1982 147 Pergamon Press Oxford
    • (1982) Ion Implantation Into Metals , pp. 147
    • Pethica, J.B.1
  • 12